Commit graph

19072 commits

Author SHA1 Message Date
Linus Torvalds
c24fd4b82c Merge branch 'open-files' of git://github.com/nathansamson/diveclog
* 'open-files' of git://github.com/nathansamson/diveclog:
  Report errors when opening files
  Make it possible to load multiple files at once.
  Open File works. I refactored the code and introduced a new type. I never used it as a pointer (their was no real reason), but I'm not really satisfied.
2011-09-05 14:44:27 -07:00
Linus Torvalds
8197d7f4d4 Add support from importing from Diving Log xml files
This is just a very rough draft.  It imports all the main stuff I
noticed, but I'm sure it drops a ton of other stuff.

Signed-off-by: Linus Torvalds <torvalds@linux-foundation.org>
2011-09-05 14:29:08 -07:00
Linus Torvalds
89593a542a Make the import source an enumeration
Instead of having each import source recognition routine set a separate
flag for that import source, just enumerate them and set them in one
variable.

I'm adding yet another xml importer - divinglog.

Signed-off-by: Linus Torvalds <torvalds@linux-foundation.org>
2011-09-05 13:45:14 -07:00
Nathan Samson
11becb8750 Report errors when opening files
Signed-off-by: Nathan Samson <nathansamson@gmail.com>
2011-09-05 22:15:30 +02:00
Nathan Samson
65ef1bae20 Make it possible to load multiple files at once.
Signed-off-by: Nathan Samson <nathansamson@gmail.com>
2011-09-05 22:15:14 +02:00
Nathan Samson
21204926df Open File works. I refactored the code and introduced a new type. I never used it as a pointer (their was no real reason), but I'm not really satisfied.
Signed-off-by: Nathan Samson <nathansamson@gmail.com>
2011-09-05 21:12:58 +02:00
Linus Torvalds
4f5e3a06ab Parse Uemis cylinder data correctly.
There's a big comment there now about what is going on.  It took me a
while to understand how the crazy seven-tank uemis dive computer
information actually works.

So the Uemis computer has 4 different "tank profiles":
 - single tank air (0)
 - single tank nitrox (1)
 - two-tank nitrox (2)
 - three-tank nitrox (3)
and the computer always lists all seven tank cases (because that's how
you fill them in).

Depending on the "gas.template" you are supposed to then *use* just one
particular profile.  Why the computer doesn't just give you the tanks
for that one profile, who knows? It seems to be more of the same "Uemis
dive data isn't so much about the dive, it's about dive computer state"
mentality.

So we first get the profile information, and then based on that we need
to pick the right tanks from the set of seven that we're presented with.

All clear?

Signed-off-by: Linus Torvalds <torvalds@linux-foundation.org>
2011-09-05 10:58:53 -07:00
Linus Torvalds
04c98344b3 Turn dive depth, temperature and duration into xml attributes
This makes the xml save-file look way nicer: it's both smaller and
better organized.  Using individual xml nodes for random small details
is silly.

The duration even parses exactly the same, because it still ends up
being '.depth.duration' (now it's the 'duration' attribute of the dive
node, it used to be the 'duration' child node of the dive node).

Signed-off-by: Linus Torvalds <torvalds@linux-foundation.org>
2011-09-05 09:48:11 -07:00
Linus Torvalds
5f79a804b9 Sanitize and fix cylinder pressure overview
Doing per-dive cylinder start/end pressures is insane, when we can have
up to eight cylinders.  The cylinder start/end pressure cannot be per
dive, it needs to be per cylinder.

This makes the save format cleaner too, we have all the cylinder data in
just one place.

Signed-off-by: Linus Torvalds <torvalds@linux-foundation.org>
2011-09-05 09:12:54 -07:00
Nikola Kotur
0f832f15d1 Comment typo fix
Signed-off-by: Nikola Kotur <kotnick@gmail.com>
2011-09-05 15:34:22 +02:00
Linus Torvalds
13a6d0c4c2 Zebra-color the divelist
..as suggested by Nathan:

  "I also wanted to "zebra" color the divelist by setting the rules-hint
   to TRUE.  but I noticed it was already set explicitly to FALSE (even
   if this is the default).

   If this is just an accidental copy paste from some tutorial you can
   experiment (set it to TRUE) and see what you like most."

It was indeed just copy-paste from some tutorial, and the zebra-coloring
does look nicer, doesn't it?

Suggested-by: Nathan Samson <nathansamson@gmail.com>
Signed-off-by: Linus Torvalds <torvalds@linux-foundation.org>
2011-09-04 15:18:58 -07:00
Linus Torvalds
5c6aa56ff1 Merge branch 'more-divelist-goodness' of https://github.com/nathansamson/diveclog
* 'more-divelist-goodness' of https://github.com/nathansamson/diveclog:
  Right align the numbers
2011-09-04 15:15:46 -07:00
Linus Torvalds
d8cca5bed3 Save milli-units with variable precision
Instead of always using three decimal digits, use 1-3 digits.  But do
use at least one, even for integer numbers, just because it makes it so
much clearer that we're dealing with potential fractional values.

Signed-off-by: Linus Torvalds <torvalds@linux-foundation.org>
2011-09-04 15:14:14 -07:00
Linus Torvalds
c66d60efa1 Use common helper for printing milli-units
I don't necessarily want to show three decimal digits when one or two
would do. So prepare for that by using a helper. This doesn't actually
change the printout yet.

Signed-off-by: Linus Torvalds <torvalds@linux-foundation.org>
2011-09-04 15:14:14 -07:00
Linus Torvalds
85921592b0 Properly save/restore cylinder description string
We saved it under the wrong name, and didn't restore it at all. Fix.

Signed-off-by: Linus Torvalds <torvalds@linux-foundation.org>
2011-09-04 15:14:14 -07:00
Linus Torvalds
e58fa7b9b5 Parse uemis cylinder data
This is some seriously crazy stuff.  Instead of making sense as a
divelog, the uemis xml makes more sense as a "dive computer settings
dump".

And I guess I can see why they'd do that.  But it makes parsing it just
incredibly annoying.  The thing is more of a "these are the
configurations I support as a dive computer thing" than a "this was the
tank you were diving with".

Signed-off-by: Linus Torvalds <torvalds@linux-foundation.org>
2011-09-04 14:56:01 -07:00
Nathan Samson
5f7835a391 Right align the numbers
Signed-off-by: Nathan Samson <nathansamson@gmail.com>
2011-09-04 23:09:19 +02:00
Linus Torvalds
e007e70053 Merge branch 'ui-tweaks' of https://github.com/nathansamson/diveclog
* 'ui-tweaks' of https://github.com/nathansamson/diveclog:
  Some UI beauty patches:
2011-09-04 13:49:45 -07:00
Linus Torvalds
f8de487c2f Make a guess at the cylinder description from the size and pressure
I'll want to also add a way to override/set the cylinder type: both
manually by just setting a size in liters, and by picking from some list
of standard cylinder sizes.

For example, it looks like most of my dives are marked as having
12-liter cylinders.  That is probably some default from Suunto Dive
Manager, or from whatever Dirk did.  It's almost certainly not right for
any of them: as far as I know, the standard cylinders for Lahaina Divers
(which is likely most of the warm water dives) are AL72's for air, and
AL80's for Nitrox.

That would be a 10L and a 11.1L tank respectively, afaik.  I don't know
what a 12-liter tank would be or where that size comes from.

Anyway, the LP85+ tank designation for some of the dives looks more
likely: that's one of the common sizes I've used for local dives.  So
the size of that thing is much more probably correct.

Signed-off-by: Linus Torvalds <torvalds@linux-foundation.org>
2011-09-04 13:34:22 -07:00
Nathan Samson
6b075e0339 Merge hbonse's UI tweaks, but fixing the compile warnings. Also bringing it up to date with the master (and my own UI improvements)
Signed-off-by: Nathan Samson <nathansamson@gmail.com>
2011-09-04 22:15:55 +02:00
Linus Torvalds
f448b68de0 Clean up 'fixup_dive()' a bit
We don't want to override potentially more exact values for water
temperature etc either.  The sample save interval may be longer than
some internally kept state of key per-dive values like that.

Signed-off-by: Linus Torvalds <torvalds@linux-foundation.org>
2011-09-04 13:06:47 -07:00
Linus Torvalds
aab4d593bd Generate date string for the dive list dynamically
.. and sort based on the 'time_t' value itself.

This allows us to use a more compact date format that doesn't need to
sort alphabetically, because sorting by date is always based on the date
value.  So we can use just a two-digit year, and skip the seconds, to
keep the column narrow, while still sorting correctly.

Also, "Depth" is a nice header string, but it is wider than the column
itself, which makes the whole column wider than necessary.  So put the
units in the header instead of in the string, keeping things narrow.

Signed-off-by: Linus Torvalds <torvalds@linux-foundation.org>
2011-09-04 12:19:20 -07:00
Linus Torvalds
230a13476d Merge branch 'ui-improvements' of https://github.com/nathansamson/diveclog
* 'ui-improvements' of https://github.com/nathansamson/diveclog:
  Split the dive list in columns. Columns are sortable now (name = date, depth, duration)
  Remove the redundant frames in the notebook. Closes #9
  Use a pane so the dive list can be made wider or smaller to the users wishes
2011-09-04 11:49:49 -07:00
Linus Torvalds
550eb862fa Merge branch 'compiler-warning' of https://github.com/nathansamson/diveclog
* 'compiler-warning' of https://github.com/nathansamson/diveclog:
  Removed the unused startemp and enttemp calculations. This fixes a compiler warning too.

Fix up trivial conflict in dive.c due to the temperature simplification
(commit 9961c7f89c: "Remove redundant temperature readings").
2011-09-04 11:46:39 -07:00
Linus Torvalds
0917436729 Add placeholder for cylinder type description
So we don't want to save working pressure, but cylinder type knowledge
would be lovely and useful.  And we can probably make a good initial
guess, or at least let people fill it in later.

Signed-off-by: Linus Torvalds <torvalds@linux-foundation.org>
2011-09-04 11:34:50 -07:00
Linus Torvalds
ecff0922d4 Don't save cylinder working pressure
It was a mistake to save it - and I did it just because other dive
managers did.  It's a totally nonsensical measure, and nobody cares.
The only thing that matters is the size of the cylinder, and the
*actual* pressures.  Those give actual air consumption numbers, and are
meaningful and unambiguous.

So the "working pressure" for a cylinder is pointless except for two
things:

 - if you don't know the actual physical size, you need the "working
   pressure" along with the air size (eg "85 cuft") in order to compute
   the physical size.  So we do use the working pressure on *input* from
   systems that report cylinder sizes that way.

 - People may well want to know what kind of cylinder they were diving,
   and again, you can make a good guess about this from the working
   pressure.  So saving information like "HP100+" for the cylinder would
   be a good thing.

But notice how in neither case do we actually want to save the working
pressure itself.  And in fact saving it actually makes the output format
ambiguous: if we give both size and working pressure, what does 'size'
mean? Is it physical size in liters, or air size in cu ft?

So saving working pressure is just wrong. Get rid of it.

I'm going to add some kind of "cylinder description" thing, which we can
save instead (and perhaps guess standard cylinders from input like the
working pressure from dive logs that don't do this sanely - which is all
of them, as far as I can tell).

Signed-off-by: Linus Torvalds <torvalds@linux-foundation.org>
2011-09-04 11:34:44 -07:00
Linus Torvalds
9961c7f89c Remove redundant temperature readings
I'm aiming to really differentiate in dive log software by making my XML
export files be *clean*, dammit.

That means that we don't have random names, we don't have crazy random
units, and we don't have redundant information.

So when the temperature doesn't change, just don't report it.  That's
already what "no sample" means, just clean things up.

Signed-off-by: Linus Torvalds <torvalds@linux-foundation.org>
2011-09-04 11:20:27 -07:00
Nathan Samson
31123f63af Split the dive list in columns. Columns are sortable now (name = date, depth, duration)
Signed-off-by: Nathan Samson <nathansamson@gmail.com>
2011-09-04 20:14:39 +02:00
Hylke Bons
c4514b062a Some UI beauty patches:
Uppercase first letter for each label word
Tweak the paddings for easier reading
Rename File menu to Log menu
Add a separator before Quit in the Log menu
Remove frame in extended diving info and add 6px padding

Signed-off-by: Hylke Bons <hylkebons@gmail.com>
2011-09-04 19:37:23 +02:00
Nathan Samson
bcf12edfe9 Merge branch 'master' into ui-improvements 2011-09-04 19:06:47 +02:00
Linus Torvalds
23a6607ae7 Fix typo in Makefile (LDLAGS -> LDFLAGS)
Reported-by: Konrad Delong <https://github.com/konryd>
Signed-off-by: Linus Torvalds <torvalds@linux-foundation.org>
2011-09-04 10:01:37 -07:00
Nathan Samson
6138d151e9 Remove the redundant frames in the notebook. Closes #9
Signed-off-by: Nathan Samson <nathansamson@gmail.com>
2011-09-04 19:01:30 +02:00
Linus Torvalds
9dc88381d2 Merge branch 'fix-entries' of https://github.com/nathansamson/diveclog
* 'fix-entries' of https://github.com/nathansamson/diveclog:
  Word wrap the info textview. Also do not show the scrollbars if not necessary.
  Change location to a text entry instead of text view.
2011-09-04 09:58:34 -07:00
Nathan Samson
1117cd37d7 Use a pane so the dive list can be made wider or smaller to the users wishes
Signed-off-by: Nathan Samson <nathansamson@gmail.com>
2011-09-04 18:54:12 +02:00
Linus Torvalds
797343bf8a Update gitignore for the name-change of the executable
It's not called 'parse' any more.  And I think I should rename 'divelog'
too to something more unique.  Right now the working name for the
project is 'diveclog' (kind of like 'jdivelog') , but I'm not convinced
that the "C implementation" part is really important enough to make a
point of long-term.

"subsurface"? I don't know.  Maybe I should follow the "name all
projects after myself" mantra.  "divenut"?

Signed-off-by: Linus Torvalds <torvalds@linux-foundation.org>
2011-09-04 09:52:40 -07:00
Linus Torvalds
a57668127e Oops. I forgot to 'fclose()' the file after saving the xml
It never actually triggered anything for me, but any buffered data might
be lost, especially if you force-exit the application after saving a
dive log.

This probably explains a corrupted (truncated) dive file report from
Nathan Samson.

Reported-by: Nathan Samson <https://github.com/nathansamson>
Signed-off-by: Linus Torvalds <torvalds@linux-foundation.org>
2011-09-04 09:50:31 -07:00
Nathan Samson
f12382c66f Removed the unused startemp and enttemp calculations. This fixes a compiler warning too.
Signed-off-by: Nathan Samson <nathansamson@gmail.com>
2011-09-04 15:18:20 +02:00
Nathan Samson
14547d8ca2 Word wrap the info textview. Also do not show the scrollbars if not necessary.
Signed-off-by: Nathan Samson <nathansamson@gmail.com>
2011-09-04 15:17:21 +02:00
Nathan Samson
5ea6b229f8 Change location to a text entry instead of text view.
Signed-off-by: Nathan Samson <nathansamson@gmail.com>
2011-09-04 15:17:11 +02:00
Linus Torvalds
a6b9eaee0a Add 'Quit' menu item, and fix invisible "File" on gtk2
I didn't even notice that the "File" part of the file menu no longer
showed up, since the keyboard accelerator for ^S worked fine..  But
apparently there's no default label associated with GTK_STOCK_FILE in
gtk2, so the "File" text went away with the conversion to GtkUIManager
in commit 4d62478e14 ("Use the newer GtkUIManager for menu creation.")

The addition of a Quit menu entry with the associated keyboard
accelerator also makes ^Q "just work".

Of course, if we actually tracked dirty state etc, we could perhaps ask
the user whether they wanted to save or something.  But I'm not exactly
famous for my GUI chops, so ..

Signed-off-by: Linus Torvalds <torvalds@linux-foundation.org>
2011-09-03 21:38:07 -07:00
Linus Torvalds
c938679726 Merge https://github.com/mrjbq7/diveclog
* https://github.com/mrjbq7/diveclog:
  dive.c: Fix spelling.
2011-09-03 20:55:02 -07:00
Linus Torvalds
6fd86ab6b7 Don't bother saving n2 percentage
It's all calculated anyway, and for the same reason we don't bother even
parsing it at load time, we really shouldn't bother saving it either.

The only thing you can do with that value is "check if the percentages
add up to 100%", and so what?

Signed-off-by: Linus Torvalds <torvalds@linux-foundation.org>
2011-09-03 20:50:11 -07:00
Nathan Samson
3a04342607 Improve the layout of the text entries in gtk3. For gtk2 this could also be useful
Signed-off-by: Nathan Samson <nathansamson@gmail.com>
Signed-off-by: Linus Torvalds <torvalds@linux-foundation.org>
2011-09-03 20:45:31 -07:00
Nathan Samson
4d62478e14 Use the newer GtkUIManager for menu creation.
Signed-off-by: Nathan Samson <nathansamson@gmail.com>
Signed-off-by: Linus Torvalds <torvalds@linux-foundation.org>
2011-09-03 20:45:22 -07:00
Linus Torvalds
b176daf6d6 Do better cylinder information management
Instead of just tracking gasmix, track the size and workng pressure of
the cylinder too.

And use "cylinder" instead of "tank" throughout.

Signed-off-by: Linus Torvalds <torvalds@linux-foundation.org>
2011-09-03 20:31:18 -07:00
John Benediktsson
f31e17a0ae dive.c: Fix spelling. 2011-09-03 18:48:39 -07:00
Linus Torvalds
c1bed52a77 Add 'mean depth' marker on dive plot
Just because I can.

Signed-off-by: Linus Torvalds <torvalds@linux-foundation.org>
2011-09-03 13:55:36 -07:00
Linus Torvalds
2804dc42d8 Only update mean/max depths with computed ones if they are way off
The computer may track "real" max depth more closely than it tracks
samples.  So we trust the non-computed mean/max depths more than the
computed ones.

Signed-off-by: Linus Torvalds <torvalds@linux-foundation.org>
2011-09-03 13:36:25 -07:00
Linus Torvalds
1e75ceac0d Add various dive fixups, and show pressure (if any) in the plot
Now the dive profile plot *really* needs some units.  The pressure is
just a random line otherwise.

Signed-off-by: Linus Torvalds <torvalds@linux-foundation.org>
2011-09-03 13:19:26 -07:00
Linus Torvalds
f8e39675cc Update README a bit
..since this is now on github, might as well tell people what they need
to compile it, and warn them about the state of the project.

Signed-off-by: Linus Torvalds <torvalds@linux-foundation.org>
2011-09-03 08:53:05 -07:00