If prefs.show_icd is false, this function does nothing, but
the output parameter is checked by the calling function
DiveEventItem::setupToolTipString().
Let's reset the strucvture to 0.
Signed-off-by: Berthold Stoeger <bstoeger@mail.tuwien.ac.at>
In pscr_o2() the result of a double calculation was implicitly
converted to int, which resulted in a gcc warning.
Part of the expression was explicitly converted to int, but then
subtracted from a double.
Instead, do all the calculations in double and cast the final
expression to int. This is probably the prudent thing to do.
Signed-off-by: Berthold Stoeger <bstoeger@mail.tuwien.ac.at>
Air is a special gas that does not contain oxygen according
to gasmix.o2.fraction. If you want to use the fo2, you
need to use get_o2() to treat this special case correctly.
This fixes a bug when setting the MND of a gas containing
21% oxygen when o2 is considered not narcotic.
Reported-by: Christoph Gruen <gruen.christoph@gmail.com>
Signed-off-by: Robert C. Helling <helling@atdotde.de>
Both the calculations for CNS and OTU did not take
into account the pO2 drop when using a PSCR. Furthermore,
there was some unit confusion due to not using internal
units.
Reported-by: arosl
Signed-off-by: Robert C. Helling <helling@atdotde.de>
Create a gastype enum, which describes the type of a gas.
For now: air, nitrox, normoxic, trimix and oxygen.
This probably should be made configurable.
The gas types will be used to bin gasses in the statistics
module.
Signed-off-by: Berthold Stoeger <bstoeger@mail.tuwien.ac.at>
Now, that we have this helper function that should have been
introduced long ago, we can make some more expressions
more idiomatic.
Signed-off-by: Robert C. Helling <helling@atdotde.de>
There were helper functions to access O2 and He component fractions.
Add another one for N2. Indeed, this can be used in three cases, where
N2 was deduced indirectly.
Moreover, add a general accessor with a gas_component argument.
This will be used by the filter code to filter for gas components.
Signed-off-by: Berthold Stoeger <bstoeger@mail.tuwien.ac.at>
But only functions that operate only on gases. Functions concerning
cylinders or dives remain in dive.c or are moved to equipment.c
Signed-off-by: Berthold Stoeger <bstoeger@mail.tuwien.ac.at>