This changeset fixes 5 issues specific to importing from Liquivision dive logs:
Issue #1: Buffer overrun causes segmentation fault.
At the end of a dive record, untranslatable data is skipped and the file is
scanned for the start of the next dive. This scan was implemented without
regard to buffer size and so the scan ran over the buffer boundary when trying
to scan for the next record after importing the last record in the file.
Issue #2: Incorrect identification of the primary sensor.
The primary tank pressure transmitter was being identified by using the sensor
ID reported in the first pressure event record encountered. When diving with
multiple transmitters (buddy, student, or group transmitters), this is often
not the case and results in the buddy or other group transmitter's pressure
data being imported instead of the primary's.
Through empirical observation of several multi-sensor logs, I identified a
previously unhandled event code (0x10) as marking a sensor identification
event record. Parsing this record allows the primary and other sensors
to be definitively identified regardless of which one sends the first pressure
event.
Issue #3: Sensor values added to the sample collection regardless of sensor ID.
When processing events, the code previously dropped through to create a sample
for every pressure event record, regardless of which sensor ID that event is
associated with. Pressure events for sensors other than the primary are now
ignored and omitted from the sample collection.
Issue #4: Duplicate samples when pressure event time syncs with sample time.
The sample index (d) was not incremented in this specific case resulting in
a duplicate sample (for the same sample time) being created when processing
the next pressure event record.
Issue #5: Unsigned time difference results in erroneous interpolated samples.
When interpolating/extrapolating depth and temperature values for a between-
samples pressure event, a signed time value is subtracted from an unsigned time
value, resulting in an unsigned term. This term is used as a scaling factor
and should be signed to allow for a negative value. Currently, negative values
are instead treated as large unsigned values which result in erroneous scaled
depth and temperature values.
Signed-off-by: Robert Bodily <robert@bodily.com>
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
Not using lrint(f) when converting double/float to int
creates rounding errors.
This error was detected by TestParse::testParseDM4 failure
on Windows. It was creating rounding inconsistencies
on Linux too, see change in TestDiveDM4.xml.
Enable -Wfloat-conversion for gcc version greater than 4.9.0
Signed-off-by: Jeremie Guichard <djebrest@gmail.com>
Having subsurface-core as a directory name really messes with
autocomplete and is obviously redundant. Simmilarly, qt-mobile caused an
autocomplete conflict and also was inconsistent with the desktop-widget
name for the directory containing the "other" UI.
And while cleaning up the resulting change in the path name for include
files, I decided to clean up those even more to make them consistent
overall.
This could have been handled in more commits, but since this requires a
make clean before the build, it seemed more sensible to do it all in one.
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
2016-04-04 22:33:58 -07:00
Renamed from subsurface-core/liquivision.c (Browse further)