This adds a graphical representation of tissue loadings at the current moment during the dive
to the tooltip box. The layout is inspired by the Sherwater Petrel.Add tissue saturation plot to tooltip
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
This adds a toolbox icon to turn on a tissue plot inspired by the bar
graph of the Sherwater Petrel,
It shows the inert gas partial pressures for individual compartments. If
they are below the ambient pressure (grey line) they are shown in units of
the ambient pressure, if they are above, the excess is shown as a
percentage of the allowed overpressure for plain Buehlmann. So it has the
same units as a gradient factor. Thus also the a gradient factor line (for
the current depth) is shown.
The different tissues get different colors, greener for the faster ones and bluer
for the slower ones.
Positioning and on/off icon action still need some tender loving care.
Signed-off-by: Robert C. Helling <helling@atdotde.de>
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
Some columns in the dive list makes more sense to have right aligned
than left aligned. This switches the numeric columns to right alignment
so they is more easily compared visually.
But, we keep the NR-column left-aligned because we use its left
indentation as dive-in-a-trip marker.
Signed-off-by: Anton Lundin <glance@acc.umu.se>
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
-change the color of the depth graph slightly to be more readable.
-change the tooltip of the depth graph to NW-corner of the cursor.
-change the opacity of the tooltip for readability.
Fixes#724
Signed-off-by: Gehad elrobey <gehadelrobey@gmail.com>
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
Converted save html to use same capitalisation style as the
rest of the application
Changed references to equipments to equipment.
Signed-off-by: Tim Wootton <tim@tee-jay.demon.co.uk>
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
This fixes two typos found by lintian.
I guess a bunch of translations will need to be updated or something, I am not
sure how they work so I didn't touch them. I presume in the worst case they
will need to be re-translated at the next iteration
--
Salvo Tomaselli
"Io non mi sento obbligato a credere che lo stesso Dio che ci ha dotato di
senso, ragione ed intelletto intendesse che noi ne facessimo a meno."
-- Galileo Galilei
http://ltworf.github.io/ltworf/
From a0e5f48349557fcccd82ba8c7555043de140835c Mon Sep 17 00:00:00 2001
From: Salvo 'LtWorf' Tomaselli <tiposchi@tiscali.it>
Signed-off-by: Salvo 'LtWorf' Tomaselli <tiposchi@tiscali.it>
Date: Fri, 12 Sep 2014 18:25:20 +0200
Subject: [PATCH] Fix typos reported by lintian
Fixes two typos reported by lintian.
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
This patch introduces a new structure holding partial pressures (doubles in bar) for
all three gases and a helper function to compute them from gasmix (which holds fractions)
and ambient pressure. Currentlty this works for OC and CCR, to be extended later to PSCR.
Currently the dive_comp_type argument is unused.
Signed-off-by: Robert C. Helling <helling@atdotde.de>
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
This adds a maxcnsText widget under infoTab and populates it.
Note that I manually edited maintab.ui to display CNS and OTU
next to each other and right after gas data.
Signed-off-by: Gaetan Bisson <bisson@archlinux.org>
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
New rules for them, a new item on the model with the text
"Empty Tags" should be marked if the user wants it to be
displayed.
Signed-off-by: Tomaz Canabrava <tomaz.canabrava@intel.com>
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
Trips will be filtered if it doesn't find any tags for
dives.
Signed-off-by: Tomaz Canabrava <tomaz.canabrava@intel.com>
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
This patch correctly filter dives based on tags, but it will
also keep showing all the empty trips.
Signed-off-by: Tomaz Canabrava <tomaz.canabrava@intel.com>
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
This method should remove a row on the dive list model
visualization if none of the tags that it have are marked
as 'visible'.
Signed-off-by: Tomaz Canabrava <tomaz.canabrava@intel.com>
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
This model accepts check / unchedk. Now, I need to also
plug the result of the check / uncheck to the list model.
Signed-off-by: Tomaz Canabrava <tomaz.canabrava@intel.com>
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
Place the TagWidget on the correct place on the main window.
Signed-off-by: Tomaz Canabrava <tomaz.canabrava@intel.com>
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
This was declared on a class definition, but never implemented.
Signed-off-by: Tomaz Canabrava <tomaz.canabrava@intel.com>
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
Just the ui file and a empty class to start playing with it.
Signed-off-by: Tomaz Canabrava <tomaz.canabrava@intel.com>
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
This patch implements the cylinder pressure calculations for diluent
gas in CCR dive computers. This is the third patch for achieving this.
The following were performed:
1) Add two lines to try_to_fill_sample() in parse-xml so that
diluent cylinder pressures are stored from XML dive log file
into structures of sample.
2) Add one line to populate_plot_entries() in profile.c so that
the diluent cylinder pressures are copied from structures of
sample to structures of plot_info.
3) add three constant #defines in profile.h
4) change populate_pressure_information() in gaspressures.c in
order to take into account pressure calculations for the
diluent cylinder, calling subordinate functions in the
appropriate way.
5) change create_plot_info_new() in profile.c in order to initiate
the pressure calculations for the diluent cylinder.
6) Implement two debugging functions (one in profile.c, another
in gaspressures.c). These debugging functions are activated
by means of #defines.
Two function calls dealing with oxygen pressure are currently commented
out. They will be activated in the following patch that attends to CCR
oxygen partial pressure calculation.
[Dirk Hohndel: rather massive whitespace cleanup]
Signed-off-by: willem ferguson <willemferguson@zoology.up.ac.za>
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
This patch adds detail to the sections that deal with the modification
of existing dive plans as well as for the copy and paste of dive
information from one dive into other dives.
Signed-off-by: willem ferguson <willemferguson@zoology.up.ac.za>
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
Application's default lang is US english, translation to
UK spelling should be done in transifex.
Signed-off-by: Tim Wootton <tim@tee-jay.demon.co.uk>
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
Sets text strings to follow the style of existing UI components in use of
capitalisation and use of :
Signed-off-by: Tim Wootton <tim@tee-jay.demon.co.uk>
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
The dive computer configuration dialog was a bit cluttered. This
change adds a tabbed interface separating the basic settings from
the gas, dilutent and set point settings
Signed-off-by: Joseph W. Joshua <joejoshw@gmail.com>
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
Commits a24eb8ac12 and 0b0860d24a introduced a nasty hack that was
needed back then to make tank and weight selection work on the Mac. But it
caused other unpleasant issues (as mentioned in the commit messages).
I re-tested this with the current Qt5.3 based builds on Mac and this hack
is no longer needed.
Fixes#638
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
Seems that Suunto stores temperature value of 0 when there is no
temperature reading (I guess). Thus this patch ignores temperature
samples that are zero. Otherwise, Subsurface looks into the samples and
grabs the lowest number as water temperature.
See #720
Signed-off-by: Miika Turkia <miika.turkia@gmail.com>
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
This is the second pathch in this series of four, allowing the calculation
of cylinder pressures for CCR equipment.
Change function fill_missing_tank_pressures in order to enable working
with the diuent gas, comprising a complete set of pressures kept separate
from all other tank pressures.
Flag diluent_flag indicates calculations for the diluent cylinder.
[Dirk Hohndel: serious whitespace cleanup]
Signed-off-by: willem ferguson <willemferguson@zoology.up.ac.za>
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
These are actually javascript files containing js objects and not json
files.
Signed-off-by: Gehad elrobey <gehadelrobey@gmail.com>
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
Remove the trailing commas from the exported JSON file as some json
parsers just don't like it. The file 'file.json' is valid acording to
the JSON spesification.
Note: its a javascript file containing a JS variable 'trips' and not a
JSON file. Because loading a pure JSON file from local disk is not
accepted by the web-browsers itself. Actually I think changing the file
extension to .js is now makes more sense.
Signed-off-by: Gehad elrobey <gehadelrobey@gmail.com>
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
The change in the French translations fixes the bug where Subsurface
couldn't find images when run in the French locale - the problem was an
incomplete translation string.
Fixes#708
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
This makes qmake aware of CFLAGS, CXXFLAGS, LDFLAGS, CPPFLAGS.
This is helpful to easily add flags to the compilation (such as
hardening flags).
Signed-off-by: Salvo 'LtWorf' Tomaselli <tiposchi@tiscali.it>
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
Turns out that the mainwindow reads the settings and sets up things -
except that this has already happened in the constructor of the static
PreferencesDialog. So only keep those parts that aren't handled there.
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>