When calculating the dive plan in the planner don't accidently use
another gas with same gasmix instead of the gas stored as
"best_first_ascend_gas".
This is important if you have e.g. a bottom stage and back gas with
same gas mix because then you always want to start your ascent with
the gas you used in last entered dive planner point.
Signed-off-by: Stefan Fuchs <sfuchs@gmx.de>
In the planner it is best practise to start the dive with the first
gas in the gaslist. Otherwise one would get a gaschange event at the
very beginning of a dive.
This change implements the following feature:
Automatically move a gas to position 0 in the gaslist if the user selects
this gas for the first dive data point.
Signed-off-by: Stefan Fuchs <sfuchs@gmx.de>
In the planner if one adds two or more cylinders with the same gasmix
(e.g. back gas and bottom stage 18/45) the drop down and data in the
used gas column of the planner points table will be filled with a more
verbose string mentioning also the cyl number and the cyl type
description.
Makes it easier in such a case to select the right cylinder.
Introduces also a helper function which tells you if there is another
cylinder with the same gasmix as the provided cylinder.
This also has an option if it should consider unused cylinders or not.
Signed-off-by: Stefan Fuchs <sfuchs@gmx.de>
Be even more restrictive regarding which cylinders can be removed from
the cylinder table in the planner.
Only if a cyliner is not used in the planned part of the dive
it can be removed.
It doesn't matter if there is another cylinder with same gasmix.
Signed-off-by: Stefan Fuchs <sfuchs@gmx.de>
With an OTA adapter - sadly I can't test that. This driver opens a
specific USB device and will ignore the connection settings. It would be
better to get some visual feedback for that (in the QML UI), but I'll
leave that until this has been verified to work.
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
It can be difficult to distinguish the new marker
which is added on the map and has to be dragged
when editing a new dive location.
By adding a new grayed-out marker it becomes
possible to gray out all other markers, while
the current marker which is being edited is still
bright red.
Suggested-by: Dietrich Meyer <dietrich@sunnynames.com>
Signed-off-by: Lubomir I. Ivanov <neolit123@gmail.com>
The QML map uses MapItemView. MapItemView needs a delagate
in the form of a MapQuickItem. The MapQuickItem needs a
'sourceItem' which would be used as the visual (e.g. marker)
on the map.
If the root sourceItem is of type Item, the marker becomes
non-clickable. If the root sourceItem is an Image, the clicks
work.
This patch removes the root Item, which makes the code
less organized, but at the same time it fixes the bug.
Bug reproduced on the following Qt versions on Ubuntu:
5.5.x, 5.7.x
Bug cannot be reproduced on Qt 5.9.x on Windows.
Reported-by: Willem Ferguson <willemferguson@zoology.up.ac.za>
Signed-off-by: Lubomir I. Ivanov <neolit123@gmail.com>
I don't think we need all the versions, but it shouldn't hurt.
Now they are alphabetical, that should make it easier.
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
This commit implements possible switching BT on and off during a session,
so not needing a restart of the app when the user forgot to switch
it on when starting the app.
For this, the following needed to be done: 1) create a handler that
reacts on local BT device status changes. 2) repopulate the connection
list in the download screen when a BT status change is detected.
Notice the subtile change of the Q_INVOKABLE btEnabled() function
to a Q_PROPERTY. This gives a nice dynamic behaviour when
switching BT on/off with the app open.
Fixes: #556
Signed-off-by: Jan Mulder <jlmulder@xs4all.nl>
Simple rewrite of a piece of code separated to its own function
so that is can be used in other places as well. To avoid code
duplication for dynamic BT on/off switching on mobile.
Signed-off-by: Jan Mulder <jlmulder@xs4all.nl>
Preparation primarily for mobile. When we want to switch in
one session from BT to cable connection and vise versa, we
need a way to clear the model data containing the possible
connections in use.
Signed-off-by: Jan Mulder <jlmulder@xs4all.nl>
Tweak some of the explanations, expand a few sections a bit more, overall try
to make the user manual even more comprehensive.
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
Following master is just not healthy. We need to be more deliberate
in which version we built against. An update in the last 24 hours
broke Subsurface-mobile again.
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
Many updates for the new UI and new features.
Completely replaced all the pictures.
Signed-off-by: Willem Ferguson <willemferguson@zoology.up.ac.za>
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
On iOS we don't need to enable ssh-based git access - and we can
no longer build against OpenSSL (instead use the platform SSL libraries.
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
In certain places the '(int)' cast is used, while in other the
llrint() or lrint() functions. Make the conversation from degrees
in the 'double' form to the 'int' degrees_t consistent using lrint().
lrint() is the function which should give the best results,
because it accepts a 'double' and results in a 'long'
even if degrees_t is 'int'. If the truncation from 'long' to 'int'
is discarding some of the precision then the next step
would be to turn degrees_t into a 64bit signed integer type.
Possible fix for #625.
Signed-off-by: Lubomir I. Ivanov <neolit123@gmail.com>
When deleting dive planner points in the planner we currently sometimes
miss to hide the outdated gas name strings printed close to the profile
legs.
Signed-off-by: Stefan Fuchs <sfuchs@gmx.de>
Calculating parameters when in the planner mode is necessary to display the correct ceiling.
Fixes#601
Signed-off-by: Rick Walsh <rickmwalsh@gmail.com>
Commit cf8e87545f implemented a way to cancel pin setup,
and this also has effects on an exit from the app after pressing
the android exit. The change button started with clearing the
email and passwd in order to get the credentail page(s) active
again. While this worked ok, it confuses users that exit the
app from the credential pages, resulting in the need to enter
the credentials again after a restart. It appears that clearing
the credential state is sufficient to get the pages active.
Notice that the android exit is still not working (it seems
a no-op), but the interaction with the buttons in the app
preserves the email/passwd.
Reported-by: Willem Ferguson <willemferguson@zoology.up.ac.za>
Signed-off-by: Jan Mulder <jlmulder@xs4all.nl>
The old credential status should only be set when changing the
actual credential status using the setCredentialStatus function.
Setting it here is just wrong. It sets the old status to the
current, and than adds the current to the prefences,
obviously, resulting in old = current, which can not be right
and results in a wrong flow of control in the credential state
processing.
Signed-off-by: Jan Mulder <jlmulder@xs4all.nl>