Mostly replace "return (expression);" by "return expression;" and one
case of "function((parameter))" by "function(parameter)".
Signed-off-by: Berthold Stoeger <bstoeger@mail.tuwien.ac.at>
as otherwise there are warning on the descent.
The ICD line in the info box is generated for all
gas switches with decreasing He content.
Also change the presentation in the info box to align it
with the notes.
Signed-off-by: Robert C. Helling <helling@atdotde.de>
Move the above function from plannernotes.c to dive.c so that
it is available to be called from the dive log part of the
software, and not only from the planner. The following was done:
1) Edit the comment above the code to make it more accurate
2) Move the structure icd_data to dive.h
3) Create an external reference in dive.h for the above function
4) Copy the body of isobaric_counterdiffusion() to dive.c
Signed-off-by: Willem Ferguson <willemferguson@zoology.up.ac.za>
There are ca. 50 constructs of the kind
same_string(s, "")
to test for empty or null strings. Replace them by the new helper
function empty_string().
Signed-off-by: Berthold Stoeger <bstoeger@mail.tuwien.ac.at>
The list iteration in dive_remove_picture() was buggy and would
crash if handled a picture that is not in the list.
Signed-off-by: Berthold Stoeger <bstoeger@mail.tuwien.ac.at>
Change the merging behavior for the following information:
Divemaster, buddy, suit:
From "(a) or (b)" to "a, b"
Notes:
From "(a) or (b)" to "a\n--\nb"
Signed-off-by: Stefan Fuchs <sfuchs@gmx.de>
Make all char * pointers in pref.h const to make it clear that these
strings are not mutable. This meant adding a number of (void *) casts
in calls to free(). Apart from being the right thing to do, this commit
makes the code more consistent, as many of the strings in pref.h were
already const.
While touching core/qthelper.cpp turn three instances of (void*) into
(void *).
Signed-off-by: Berthold Stoeger <bstoeger@mail.tuwien.ac.at>
Fixup the NDL value to '-1' at the very beginning of a dive.
Some dive computer report a NDL of 0 at the very beginning of a dive
and then only some 10 seconds later they report the correct value
like 240 min for the first time.
Translate this 0 at the beginning of a dive into our internal '-1'
for no info available.
Signed-off-by: Stefan Fuchs <sfuchs@gmx.de>
Type duration_t changed from uint to int.
Default value of '-1' introduced for some of the values in struct sample:
NDL used -1 as default.
Bearing uses -1 as default (no bearing set).
Display pXX, EAD, END, density, MOD only if values are larger than 0.
In profile don't display data from two first and two last plot_data
entries in info box.
Signed-off-by: Stefan Fuchs <sfuchs@gmx.de>
The pressure information of cylinder should be kept intact when
copy-pasting other cylinder related information from other dive.
According to Dirk, the gas mix is wanted to be changed as technical
divers might have always the same multiple cylinders and wish to copy
the gasmix information over.
Fixes#689
Signed-off-by: Miika Turkia <miika.turkia@gmail.com>
In the planner if one adds two or more cylinders with the same gasmix
(e.g. back gas and bottom stage 18/45) the drop down and data in the
used gas column of the planner points table will be filled with a more
verbose string mentioning also the cyl number and the cyl type
description.
Makes it easier in such a case to select the right cylinder.
Introduces also a helper function which tells you if there is another
cylinder with the same gasmix as the provided cylinder.
This also has an option if it should consider unused cylinders or not.
Signed-off-by: Stefan Fuchs <sfuchs@gmx.de>
When planning a new dive (not replan!!!) based on an existing (planned)
dive, the cylinders from the existing selected dive are copied.
This patch guarantees that cylinders which had been marked as "unused"
are indeed copied as well. Sounds strange at the first moment but makes
sense because if one marks a cylinder explicitly as "unused" in the
planner instead of deleting it that does mean that one wants to keep
this cylinder to have it available and be able to reenable it later-on.
Signed-off-by: Stefan Fuchs <sfuchs@gmx.de>
When we merge dives, the sample_start and sample_end pressures are only
used in-memory for displaying data to the user. However, we should
update them as well as this will show the user the correct data in the
equipment/cylinder and i.e. SAC calculation.
Fixes#577
Signed-off-by: Miika Turkia <miika.turkia@gmail.com>
As these are probably manually entered dives with incomplete data, it is
better not to merge them.
See #561
Signed-off-by: Miika Turkia <miika.turkia@gmail.com>
The momentary SAC rate got broken by the multiple ressure handling too,
and always used just the first cylinder.
This uses the new "get_gasmix()" helper to see what you're breathing,
and will do the SAC rate over all the cylinders that contain that gas.
So it should now DTRT even for sidemount diving (assuming you had the
same gas in the sidemount cylinders).
NOTE! We could just do the SAC rate over *all* the gases you have
pressures for, and maybe that's the right thing to do. The ones you are
not breating from shouldn't have their pressure change. But maybe some
people add their drysuit argon gas to the gas list?
So this may need more work, but it's a step in the right direction.
Signed-off-by: Linus Torvalds <torvalds@linux-foundation.org>
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
This finally handles multiple cylinder pressures, both overlapping and
consecutive, and it seems to work on the nasty cases I've thrown at it.
Want to just track five different cylinders all at once, without any
pesky gas switch events? Sure, you can do that. It will show five
different gas pressures for your five cylinders, and they will go down
as you breathe down the cylinders.
I obviously don't have any real data for that case, but I do have a test
file with five actual cylinders that all have samples over the whole
course of the dive. The end result looks messy as hell, but what did
you expect?
HOWEVER.
The only way to do this sanely was
- actually make the "struct plot_info" have all the cylinder pressures
(so no "sensor index and pressure" - every cylinder has a pressure for
every plot info entry)
This obviously makes the plot_info much bigger. We used to have
MAX_CYLINDERS be a fairly generous 8, which seems sane. The planning
code made that 8 be 20. That seems questionable. But whatever.
The good news is that the plot-info should hopefully get freed, and
only be allocated one dive at a time, so the fact that it is big and
nasty shouldn't be a scaling issue, though.
- the "populate_pressure_information()" function had to be rewritten
quite a bit. The good news is that it's actually simpler now, although
I would not go so far as to really call it simple. It's still
complicated and suble, but now it explicitly just does one cylinder at
a time.
It *used* to have this insanely complicated "keep track of the pressure
ranges for every cylinder at once". I just couldn't stand that model
and keep my sanity, so it now just tracks one cylinder at a time, and
doesn't have an array of live data, instead the caller will just call
it for each cylinder.
- get rid of some of our hackier stuff, like the code that populates the
plot_info data code with the currently selected cylinder number, and
clears out any other pressures. That obviously does *not* work when you
may not have a single primary cylinder any more.
Now, the above sounds like all good things. Yeah, it mostly is.
BUT.
There's a few big downsides from the above:
- there's no sane way to do this as a series of small changes.
The change to make the plot_info take an array of cylinder pressures
rather than the sensor+pressure model really isn't amenable to "fix up
one use at a time". When you switch over to the new data structure
model, you have to switch over to the new way of populating the
pressure ranges. The two just go hand in hand.
- Some of our code *depended* on the "sensor+pressure" model. I fixed all
the ones I could sanely fix. There was one particular case that I just
couldn't sanely fix, and I didn't care enough about it to do something
insane.
So the only _known_ breakage is the "TankItem" profile widget. That's
the bar at the bottom of the profile that shows which cylinder is in
use right now. You'd think that would be trivial to fix up, and yes it
would be - I could just use the regular model of
firstcyl = explicit_first_cylinder(dive, dc)
.. then iterate over the gas change events to see the others ..
but the problem with the "TankItem" widget is that it does its own
model, and it has thrown away the dive and the dive computer
information. It just doesn't even know. It only knows what cylinders
there are, and the plot_info. And it just used to look at the sensor
number in the plot_info, and be done with that. That number no longer
exists.
- I have tested it, and I think the code is better, but hey, it's a
fairly large patch to some of the more complex code in our code base.
That "interpolate missing pressure fields" code really isn't pretty. It
may be prettier, but..
Anyway, without further ado, here's the patch. No sign-off yet, because I
do think people should look and comment. But I think the patch is fine,
and I'll fix anythign that anybody can find, *except* for that TankItem
thing that I will refuse to touch. That class is ugly. It needs to have
access to the actual dive.
Note how it actually does remove more lines than it adds, and that's
despite added comments etc. The code really is simpler, but there may be
cases in there that need more work.
Known missing pieces that don't currently take advantage of concurrent
cylinder pressure data:
- the momentary SAC rate coloring for dives will need more work
- dive merging (but we expect to generally normally not merge dive
computers, which is the main source of sensor data)
- actually taking advantage of different sensor data from different
dive computers
But most of all: Testing. Lots and lots of testing to find all the
corner cases.
Signed-off-by: Linus Torvalds <torvalds@linux-foundation.org>
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
We had a "add_sample_pressure()" helper functions that was local to just
the libdivecomputer downloading code, but it really is applicable to
pretty much any code that adds cylinder pressure data to a sample.
Also add another helper: "legacy_format_o2pressures()" which checks the
sample data to see if we can use the legacy format, and returns the o2
pressure sensor to use for that legacy format.
Because both the XML and the git save format will need a way to save the
compatible old-style information, when possible, but save an extended
format for when we have data from multiple concurrent sensors.
Signed-off-by: Linus Torvalds <torvalds@linux-foundation.org>
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
This tries to sanely handle the case of a dive computer reporting
multiple cylinder pressures concurrently.
NOTE! There are various "interesting" situations that this whole issue
brings up:
- some dive computers may report more cylinder pressures than we have
slots for.
Currently we will drop such pressures on the floor if they come for
the same sample, but if they end up being spread across multiple
samples we will end up re-using the slots with different sensor
indexes.
That kind of slot re-use may or may not end up confusing other
subsurface logic - for example, make things believe there was a
cylidner change event.
- some dive computers might send only one sample at a time, but switch
*which* sample they send on a gas switch event. If they also report
the correct sensor number, we'll now start reporting that pressure in
the second slot.
This should all be fine, and is the RightThing(tm) to do, but is
different from what we used to do when we only ever used a single
slot.
- When people actually use multiple sensors, our old save format will
start to need fixing. Right now our save format comes from the CCR
model where the second sensor was always the Oxygen sensor.
We save that pressure fine (except we save it as "o2pressure" - just
an odd historical naming artifact), but we do *not* save the actual
sensor index, because in our traditional format that was always
implicit in the data ("it's the oxygen cylinder").
so while this code hopefully makes our libdivecomputer download do the
right thing, there *will* be further fallout from having multiple
cylinder pressure sensors. We're not done yet.
Signed-off-by: Linus Torvalds <torvalds@linux-foundation.org>
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
This is a very timid start at making us actually use multiple sensors
without the magical special case for just CCR oxygen tracking.
It mainly does:
- turn the "sample->sensor" index into an array of two indexes, to
match the pressures themselves.
- get rid of dive->{oxygen_cylinder_index,diluent_cylinder_index},
since a CCR dive should now simply set the sample->sensor[] indices
correctly instead.
- in a couple of places, start actually looping over the sensors rather
than special-case the O2 case (although often the small "loops" are
just unrolled, since it's just two cases.
but in many cases we still end up only covering the zero sensor case,
because the CCR O2 sensor code coverage was fairly limited.
It's entirely possible (even likely) that this migth break some existing
case: it tries to be a fairly direct ("stupid") translation of the old
code, but unlike the preparatory patch this does actually does change
some semantics.
For example, right now the git loader code assumes that if the git save
data contains a o2pressure entry, it just hardcodes the O2 sensor index
to 1.
In fact, one issue is going to simply be that our file formats do not
have that multiple sensor format, but instead had very clearly encoded
things as being the CCR O2 pressure sensor.
But this is hopefully close to usable, and I will need feedback (and
maybe test cases) from people who have existing CCR dives with pressure
data.
Signed-off-by: Linus Torvalds <torvalds@linux-foundation.org>
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
We currently carry two pressures around for all the samples and plot
info, but the second pressure is reserved for CCR dives as the O2
cylinder pressure.
That's kind of annoying when we *could* use it for regular sidemount
dives as the secondary pressure.
So start prepping for that instead: don't make it "pressure" and
"o2pressure", make it just be an array of two pressure values.
NOTE! This is purely mindless prepwork. It literally just does a
search-and-replace, keeping the exact same semantics, so "pressure[1]"
is still just O2 pressure.
But at some future date, we can now start using it for a second sensor
value for sidemount instead.
Signed-off-by: Linus Torvalds <torvalds@linux-foundation.org>
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
The core to avoid adding redundant gas switch events was completely
buggered, and caused the result list to be corrupted if it ever
triggered. This should fix it.
Fixes: b5de08b7 ("No gas change event on merging dives with same gas")
Reported-by: Jan Mulder <jlmulder@xs4all.nl>
Cc: Miika Turkia <miika.turkia@gmail.com>
Cc: Dirk Hohndel <dirk@hohndel.org>
Signed-off-by: Linus Torvalds <torvalds@linux-foundation.org>
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
... for consistency, while we are at it.
There are still some internal depth variables which are ints
somebody might take a go at those.
Signed-off-by: Robert C. Helling <helling@atdotde.de>
This is needed in the altitude pressure conversion as there
negative altitudes are possible (for diving in the netherlands
or the Dead Sea).
Signed-off-by: Robert C. Helling <helling@atdotde.de>
Using gcc option "-Wfloat-conversion" is useful to catch
potential conversion errors (where lrint should be used).
rint returns double and still raises the same warning,
this is why this change updates all rint calls to lrint.
In few places, where input type is a float, corresponding
lrinf is used.
Signed-off-by: Jeremie Guichard <djebrest@gmail.com>
When merging, we should treat an empty dive site (which will be deleted
on save) the same as not having a dive site.
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
I have no idea why we only merged air temperatures. But it was very
explicit (even the function doing the merging was named
"merge_airtemp()"), and water temperatures were left alone.
Signed-off-by: Linus Torvalds <torvalds@linux-foundation.org>
The test for the dive being a planned dive was completely bogus:
- it should use "same_string()" which correctly checks for NULL
- the string it checks for is obviously spelled wrong anyway.
Reported-by: Alessandro Volpi <volpial@gmail.com>
Fixes: a031dbbbd ("When merging planned dives keep all cylinders")
Signed-off-by: Linus Torvalds <torvalds@linux-foundation.org>
This makes some further updates to the new cylinder merging code:
- avoid re-using the cylinder if the usage type (OC/diluent/O2) is
different between the two dives, even if the gasmix might be the
same.
- avoid re-using a cylinder if the user has manually added pressure
data for it (and the pressures don't match)
- when deciding to reuse a cylinder, make sure that we merge as much of
the type information as makes sense.
This will potentially result in more cylinders that might need manual
cleanup, but at least we won't be throwing out user data. And in most
cases where merging happens, none of this is an issue (because the data
comes fresh from a dive computer, and won't have been manually edited to
trigger the new rules).
Signed-off-by: Linus Torvalds <torvalds@linux-foundation.org>
The old cylinder merging code depended on the preferred dive having all
the cylinders, and the newly merged dive was just forced to pick from
that existing set of cylinders.
That worked ok if you have a "main" dive computer that you have all the
gases programmed for, and you download that first, and then you download
any secondary data later.
But it completely messed up if the second dive computer had gases that
the first one didn't know about, and just basically ended up doing
random things.
This rewrites the whole thing to actually try to create a union of the
two sets of cylinders when merging, with sane matching so that if the
cylinders match you won't get duplicates.
Miika Turkia hit this when he only used one gas, but had several gases
defined in his OSTC that he downloaded after his Vyper (with had just
the single gas defined).
This should fix that case (at least it does for my xml merging test-case
that showed the same problem after some munging).
Reported-by: Miika Turkia <miika.turkia@gmail.com>
Signed-off-by: Linus Torvalds <torvalds@linux-foundation.org>
There is no need to have two variables for the same purpose.
[Dirk Hohndel: changed to keep the two separate functions as otherwise
we no longer parse existing repos successfully]
Signed-off-by: Joakim Bygdell <j.bygdell@gmail.com>
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
In order to streamline the view between desktop and mobile we need to save
selected profile related settings to git.
Signed-off-by: Joakim Bygdell <j.bygdell@gmail.com>
When the first leg in the planner is not cylinder 0, a gaschange
event at t=1s is inserted. In the profile, we should treat that
as inital gas, so no pressure information is printed for cylinder 0
that is used nominally for one second.
This fixes a problem reported by Willem.
Signed-off-by: Robert C. Helling <helling@atdotde.de>