We currently don't support update firmware for the OSTC3. Where waiting
for support in libdivecomputer for that, so disable that button for now.
Signed-off-by: Anton Lundin <glance@acc.umu.se>
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
This code connects the final parts of the generic firmware update code.
Signed-off-by: Anton Lundin <glance@acc.umu.se>
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
Normally, all samples have depths associated with them, and most dive
computers likely don't even have the concept of a sample without a depth.
However, the new Suunto EON Steel definitely has samples with just time
updates (and perhaps other data, like events) and no depth at all. We
get unhappy about that, and interpret it as having a zero depth. Which
doesn't look very nice.
This just makes all samples default to the same depth as the previous
sample. For normal samples with a depth value, that will just override
that default.
Signed-off-by: Linus Torvalds <torvalds@linux-foundation.org>
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
-make the dive profile dynamic to check user selected units from the
settings file.
-some of the code needs to be refactored and copied to a more
appropriate location.
Signed-off-by: Gehad elrobey <gehadelrobey@gmail.com>
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
Edit the HTML exporter to export data fields with user selected units.
Signed-off-by: Gehad elrobey <gehadelrobey@gmail.com>
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
Working on HTML exports to support imperial and metric units and also
custom selected units based on subsurface preferences.
User selected units is exported to settings file that will be mainly used
by listlib javascript file.
Signed-off-by: Gehad elrobey <gehadelrobey@gmail.com>
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
The pre-existing tissue load going into a dive can change if the start
time of a dive changes. Therefore we need to recalculate the ceiling when
editing start time (or date) of a dive.
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
While the existing code worked fine for editing that start date or time of
dives downloaded from a dive computer or imported from some other source,
for manually entered dives this did not work and the date or time was
always reset to the original time once the changes were saved.
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
Ensure that there is no (clipped) overflowfrom the header.
Signed-off-by: Giuseppe Bilotta <giuseppe.bilotta@gmail.com>
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
The previous hard-coded solution for GTK+ didn't work on HiDPI, and a
comment hinted that even on Mac OS X it might need tuning. Find a more
generic solution that should work regardless of platform and style,
based purely on the geometries reported by the style itself.
Signed-off-by: Giuseppe Bilotta <giuseppe.bilotta@gmail.com>
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
Also, generate the corresponding pixmap only once, and distribute it to
all models that need it.
Signed-off-by: Giuseppe Bilotta <giuseppe.bilotta@gmail.com>
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
The latest CCR patches had rendered the planner not usable for CCR dives.
This patch corrects this (and reenables the CCR set point column for
segments). The problem was that a new member setpoint of struct divepoint
had been introduced, but there was already po2 which had the same meaning.
This patch merges the two and renames them setpoint to prevent future
confusion.
Signed-off-by: Robert C. Helling <helling@atdotde.de>
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
The OSTC3 stores the pressure sensor offset as a signed 8-bit integer.
Signed-off-by: Anton Lundin <glance@acc.umu.se>
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
This adds the settings not previously available in the OSTC3 settings.
Signed-off-by: Anton Lundin <glance@acc.umu.se>
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
This creates a Advanced settings page for the OSTC3 and moves the deco
settings off to that page.
Signed-off-by: Anton Lundin <glance@acc.umu.se>
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
These settings are gas related so they fitted in the spare space in the
gas screen.
Signed-off-by: Anton Lundin <glance@acc.umu.se>
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
I hope this time I got it right. basically, the old code
tried to guess where the plus icon should be with a fairly
bad set of defauults.
This one patch asks for the Qt style where everything is and
uses that knowledge to make it be in a more sane position.
Signed-off-by: Tomaz Canabrava <tomaz.canabrava@intel.com>
Signed-off-by: Giuseppe Bilotta <giuseppe.bilota@gmail.com>
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
Collect font, font metrics and icon size functions in a separate module.
Signed-off-by: Giuseppe Bilotta <giuseppe.bilotta@gmail.com>
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
Compute the default widths for the columns in the dive trip list from
their header and (expected) content length rather than some fixed pixel
sizes.
Signed-off-by: Giuseppe Bilotta <giuseppe.bilotta@gmail.com>
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
Don't hard-code column widths or icon sizes/positions. Instead, compute
them from the fonts used.
Signed-off-by: Giuseppe Bilotta <giuseppe.bilotta@gmail.com>
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
Instead of hard-coding the icon sizes and spacing, compute them from the
font sizes, that Qt auto-computes from the displya DPI.
Signed-off-by: Giuseppe Bilotta <giuseppe.bilotta@gmail.com>
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
The default IMG_SIZE and SPACING in the StarWidget are not appropriate
for HiDPI displays. Replace them with StarMetrics which are
auto-computed from the (default) font size (which Qt determines from the
display DPI settings).
Signed-off-by: Giuseppe Bilotta <giuseppe.bilotta@gmail.com>
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
The type is now a double. It was a int during development, but due to
the feet/128 precision i changed it to a Double, but the default value
wasn't changed type on.
All the Qt tools swallowed the number there without complaining but the
Qt designer insisted on changing it to a double.
Signed-off-by: Anton Lundin <glance@acc.umu.se>
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
The fist column is the O2% value, and was handled like that in the data.
It was only the column header that was wrong.
Signed-off-by: Anton Lundin <glance@acc.umu.se>
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
There was a missing break after writing the settings to the OSTC3. It
caused us to fall down into the default case and saying that the
operation was unsupported.
Signed-off-by: Anton Lundin <glance@acc.umu.se>
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
The OSTC3 settings code read the data from the computer into spData, but
set the data into the devicedetails object from dilData.
Signed-off-by: Anton Lundin <glance@acc.umu.se>
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
Almost all of our other classes have the ui class as a class member in
the controller code. This switches ConfigureDiveComputerDialog to that
model.
Signed-off-by: Anton Lundin <glance@acc.umu.se>
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
Disable the Update Firmware button if you choose a device that we don't
support update firmware for.
Signed-off-by: Anton Lundin <glance@acc.umu.se>
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
Don't allow creation of backup files or writes to the computer before we
know we got some data, either from a backup file or from the actual
device.
Signed-off-by: Anton Lundin <glance@acc.umu.se>
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
The default max value for a QSpinBox is 99. The default Saturation
factor for the OSTC3 is 110%. This code sets the max, min and default
values on those spinboxes.
The values comes from me reading the assembler code for the OSTC3.
Signed-off-by: Anton Lundin <glance@acc.umu.se>
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
The default max value for a QSpinBox is 99. The default Saturation
factor for the OSTC3 is 110%. This code raises the max values to 255
which is as far as i've read the ostc3_interface.odt the max value.
Signed-off-by: Anton Lundin <glance@acc.umu.se>
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
This adds missing code to read and write the desaturation factor to and
from OSTC3's.
Signed-off-by: Anton Lundin <glance@acc.umu.se>
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
fill_o2_values() in profile.c: Robert identified the inconsistency of po2
assignmemts when using OC dives as opposed to CCR dives.
This is corrected here. OC dives still need to be processed in this function
because the po2 values have not been initialised anywhere else before
thos code executes.
Signed-off-by: willem ferguson <willemferguson@zoology.up.ac.za>
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>