If there are no gas mixes returned by libdivecomputer, we need to default to air. The previous commit would have defaulted to pure oxygen.
Signed-off-by: Micha WERLE <micha@michaelwerle.com>
During code review, an argument was made to use the bottom gas mix as
the mix to fill additional tanks with instead of the last mix reported
by the dive computer.
This change implements `get_deeper_gasmix` which compares two gas mixes
and returns the one with the lower MOD. This comparison does not perform
actual MOD calculations but only performs a relative oxygen and helium
content comparison.
Instead of saving the last gas mix and assigning it to additional tanks,
a `bottom_gas` mix is saved and assigned instead.
Signed-off-by: Micha WERLE <micha@michaelwerle.com>
Reverted "optimisation" based on code feedback.
Firstly, it's implementation-defined whether or not a stack frame is created for sub-scopes, secondly any optimisation is questionable regardless, and thirdly it was felt that it makes the code harder to understand.
Signed-off-by: Micha WERLE <micha@michaelwerle.com>
Instead of defaulting to air when we run out of gas mixes to assign to
cylinders, use the last gas mix provided by the dive computer.
If no gas mixes are provided at all, then default to air.
This prevents Subsurface from "inventing" gas mixes which are not
reported by the dive computer. It also works very nicely with a sidemount
configuration where the dive computer typically reports two cylinders but
only a single gas mix.
Signed-off-by: Micha WERLE <micha@michaelwerle.com>
The divecomputer_device_open() function tries all supported transports
one by one, and exits as soon as one is opened successfully. When the
end of the function is reached, the DC_STATUS_UNSUPPORTED error code is
returned.
The annoying side effect is that the actual error code returned by the
transport is ignored and changed into DC_STATUS_UNSUPPORTED. This is
very confusing while troubleshooting download problems.
Fixed by initializing the error code to DC_STATUS_UNSUPPORTED, in case
no transport is available for trying, and returning the last reported
error to caller.
Signed-off-by: Jef Driesen <jef@libdivecomputer.org>
Add the Aqualung i330R and Apeks DSX model numbers to the Pelagic
pattern table. These two models also use a new BLE service UUID.
Signed-off-by: Jef Driesen <jef@libdivecomputer.org>
The UUID of the Divesoft BLE service needs to be added to the list of
known services. It's a 16-bit UUID that gets detected as a standard
service and is ignored otherwise.
Signed-off-by: Jef Driesen <jef@libdivecomputer.org>
When we've already seen a trimix gas, of we after that see a nitrox gas
with less o2, it shouldn't update the mino2 state.
Signed-off-by: Anton Lundin <glance@ac2.se>
When the import from a dive computer gives you 100% as the first gas,
the get_dive_gas never finds which gas had the lowest o2 percent.
This fixes the logic to find the lowest o2 percent in any dive cylinder
list.
Signed-off-by: Anton Lundin <glance@ac2.se>
It looks kinda strange that all CCR dives have a dive gas ..100%, so
rather than showing it as the dive gas used, just ignore cylinders
with usage flagged as oxygen.
Signed-off-by: Anton Lundin <glance@ac2.se>
If enabling the notification fails, receiving data packets is not
possible. Instead of silently ignoring this fatal problem and trying to
continue, report the error back to the caller.
Signed-off-by: Jef Driesen <jef@libdivecomputer.org>
The existing logic correctly calculates the minimum (ie, ending) pressure, but not the maximum
(ie starting) pressure.
For example, 2 tanks A and B with manual pressures (same tank on subsequent dives, which were
then merged):
A: 205 - 84
B: 83 - 55
When merging the starting pressures, the call is : merge_pressure(205, 0, 83, 0, false)
The final comparison is:
if(false && 205 < 83) return 205;
else return 83;
-> So 83 is returned even though 205 should have been.
Signed-off-by: Michael Werle <micha@michaelwerle.com>
When events are hidden in the profile, only hide events with the same
name and the same severity (flags).
From discussion in https://github.com/subsurface/libdc/pull/54.
Signed-off-by: Michael Keller <github@ike.ch>
Fix how gases are marked as 'used' and kept from being deleted in the
equipment tab for CCR dives.
It does not make sense to treat the (arbitrary) first gas in the list
with a usage type of 'diluent' or 'oxygen' as 'used' and prevent the
user from deleting it. Dive computers report the initial diluent and
any other diluents used through a 'gaschange' event, so the actually
used diluents are already picked up as part of gaschange event based
logic.
Also clarify the selection of the first diluent used as a default if no
gaschange events exist.
Also fixed the test data - gases that have a pressure change should be
included in the profile if they do not have a gas change recorded
against them by other dive computers, even if they are oxygen.
A secondary problem shown by this is that the pressure change is not
applied to the profile - the pressure is currently shown as constant on
the start pressure. But this is for another pull request.
Signed-off-by: Michael Keller <github@ike.ch>
Include unused tanks in merges of multiple logs into a single dive if
the 'Show unused cylinders' preference is enabled.
Also rename the preference (in code) to `include_unused_tanks` to
reflect the fact that it is already used in more places than just the
display (exporting, cloning dives).
Simplified the cylinder model to make forced inclusion of unused tanks
dependent on use of the model in planner.
Leaving the persisted name of the preference as `display_unused_tanks`
to avoid resetting this for all users - is there a good way to migrate
preference names?
Signed-off-by: Michael Keller <github@ike.ch>
Mark gases that are reported as 'inactive' by the dive computer as 'not
used' in the Equipment tab.
Requires https://github.com/subsurface/libdc/pull/52.
Signed-off-by: Michael Keller <github@ike.ch>
The conversion between mbar and depth sometimes uses DC's salinity, sometimes user's salinity. By other hand, it uses surface pressure given by user in calculation.
This fix try to standartize this values, using them from same source.
Signed-off-by: Rafael M. Salvioni <rafael.salvioni@gmail.com>
Add a button that allows the user to hide the infobox with statistics
about the point in the dive under the mouse cursor in order to be able
to see the full dive profile unobstructed.
Signed-off-by: Michael Keller <github@ike.ch>
Add meaningful error messages when creating a libdivecomputer dump. In
particular show if creating a dump is not supported on the dive computer
that is used.
Signed-off-by: Michael Keller <github@ike.ch>
The memory management and string concatenation was hard to follow.
Since the mobile files ios.cpp and android.cpp were already
converted to C++, let's do the same for Unix, Windows and MacOS.
Simply store the default directory and filename in a function-level
static string. Thus, it will be initialized on first call and
freed on application exit. Since the std::string data is
guaranteed to be contiguous and zero-terminated, it can be used
from C code.
Signed-off-by: Berthold Stoeger <bstoeger@mail.tuwien.ac.at>
Add support for tracking the gas usage across multiple tanks to the 'bar
used' and SAC values shown for the profile ruler.
The following rules are implemented:
- a tank is considered 'used' if at least one bar has been consumed;
- only used tanks are taken into account for calculations;
- 'bar used' is only shown if all tanks used have the same (or unknown)
volume;
- SAC is only shown if all tanks used have a known volume.
Fixes#3902.
Reported-by: @pabdakine
Signed-off-by: Michael Keller <github@ike.ch>
Remove `renderSVGIcon()` and `renderSVGIconWidth()`, as QPixmaps can be
loaded directly from SVG, and support scaling.
Signed-off-by: Michael Keller <github@ike.ch>
It's possible for the first sensor to start with a pressure
significantly lower than other sensors.
Signed-off-by: Michael Andreen <michael@andreen.dev>
This has to be applied to the object, not the pointer to the object.
Fixes a double-free crash introduced in 8cd451f.
Alternatively, we could use std::swap() for C++98 charm and perhaps
better readability for people unfamiliar with C++11. Nowadays,
std::move() is more idiomatic though. Shrug.
Reported-by: Michael Keller <github@ike.ch>
Signed-off-by: Berthold Stoeger <bstoeger@mail.tuwien.ac.at>
Add an option for users to sync the dive computer time with the PC time
every time dives are downloaded.
Obviously this will only work on dive computers that have time
synchronisation support in libdivecomputer, for other computers a notice
is logged.
The selection for this option is persisted as a preference.
Signed-off-by: Michael Keller <github@ike.ch>
The undo-code uses owning pointers based on std::unique_ptr to
manage lifetime of C-objects. Since these are generally useful,
move them from the undo-code to the core-code. In fact, this
eliminates one instance of code duplication.
Signed-off-by: Berthold Stoeger <bstoeger@mail.tuwien.ac.at>
displayed_dive used to contain the currently displayed (as in
shown on the profile) dive. However, now it is only a "scratch"
dive used by the planner and initialized every time the planner
is started. There is no point in clearing this dive when clearing
the dive data. In fact, the dive should probably be cleared when
the planner finishes.
Signed-off-by: Berthold Stoeger <bstoeger@mail.tuwien.ac.at>
The current dc global makes no sense on mobile. Therefore,
move the logic of the currently displayed dive computer
to the profile widget and remove the dc_number global
variable.
Signed-off-by: Berthold Stoeger <bstoeger@mail.tuwien.ac.at>
This was very weird: a setSelection() call was always followed
by a selectionChanged() call, though sometimes in convoluted
ways. Notably, the formed was called by the DiveListView, the
lattern then by the MainWindow.
Let's just merge these two functions.
Signed-off-by: Berthold Stoeger <bstoeger@mail.tuwien.ac.at>
The trip selection code was an awkward layering violation.
Whereas dive selections due to dive undo-commands trickled
down via DiveTripModel-->MultiFilterSortModel-->DiveListView,
for trip editing, the DiveListView directly intercepted the
TripEdited signal.
Instead, mimic the dive-selection code. This is a bit longer
but more consistent and logical. The undo/redo of trip changes
is now also a "programmatical" change of the selection.
Signed-off-by: Berthold Stoeger <bstoeger@mail.tuwien.ac.at>
After sending a selection-change signal, there follows a current
dive changed signal. Combine these two into a single signal, since
usually the current dive is changed when the selection is changed.
Signed-off-by: Berthold Stoeger <bstoeger@mail.tuwien.ac.at>
These were not optimal, because they would recalculate the current
dive and divecomputers for every invocation.
Signed-off-by: Berthold Stoeger <bstoeger@mail.tuwien.ac.at>
delete_single_dive() is one of those remnants from before the
undo-code. Now it is only called in two contexts:
1) When clearing the whole dive log.
2) When importing dives from the cloud on mobile.
In the first case, the selection is cleared before deleting
the dives.
In the second case, let's just do the same.
Thus, we can remove the last call to the deselect_dive()
function that does some complex calculations concerning
the current dive and divecomputer.
Signed-off-by: Berthold Stoeger <bstoeger@mail.tuwien.ac.at>
Each of these calls recalculates the current dive and divecomputer.
Instead, collect the dives to be selected/deselected and (de)select
them at once.
This needs some code refactoring in the core, because we need a
function that
1) doesn't send a signal by itself.
2) doesn't clear the trip-selection.
This contains some reorganization of the selection functions
signatures: The filter code is the only caller that keeps the
selected dive and the only caller that cares about whether the
current dive changed. So let only the function that keeps the
selected dive return whether the current dive changed.
It's all very fragile.
Signed-off-by: Berthold Stoeger <bstoeger@mail.tuwien.ac.at>
For each selected dive that is hidden by the filter,
unselect_dive() was called, which led to a recalculation
of the current dive and divecomputer.
Instead, collect all deselected dives and deselect them
at the end. Thus, these calculations are performed
only once.
Signed-off-by: Berthold Stoeger <bstoeger@mail.tuwien.ac.at>
This tries to encapsulate the management of the current dive and
divecomputer in the selection code. The current dive is alreay
set by setSelection(). Add a new parameter to also set the
current divecomputer. If -1 is passed, then the current
computer number is remained. This will allow us to audit the code.
Because for now, the whole "current dive computer" thing seems
to be ill-defined.
This fixes a bug: the dive-computer number wasn't validated
when making a new dive the current dive. The new code has some
drawbacks though: when selecting a whole trip, the validation
will be called for all dives in the trip and thus the dive computer
number will depend on the dive with the lowest amount of dive
computers in the trip. This will need to be fixed.
Signed-off-by: Berthold Stoeger <bstoeger@mail.tuwien.ac.at>