We cannot zero setpoint value upon import if the current and previous
values are zero. This is because on setpoint context a value of 0 means
open circuit.
Signed-off-by: Miika Turkia <miika.turkia@gmail.com>
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
DiveLogExportDialog::export_depths()
We set a default value of 'unit' which will silence the warning itself.
Then hope that the compiler will respect the argument order i.e. call
get_depth_units() (which sets 'unit') before using *unit as the last
argument passsed to put_format().
Signed-off-by: Lubomir I. Ivanov <neolit123@gmail.com>
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
"gridLayout_1" is used twice. Re-order the grid layouts as 1, 2, 3.
Signed-off-by: Lubomir I. Ivanov <neolit123@gmail.com>
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
MainWindow::on_actionReplanDive_triggered():
If a dive in the divelist does not have a "DC Model" for some reason,
selecting "re-plan" from the menu will pass a NULL value
current_dive->dc.model to strcmp() and break before the debug output.
To fix that we check if the said .model value is NULL.
Signed-off-by: Lubomir I. Ivanov <neolit123@gmail.com>
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
This patch adds support for importing the logs from a Poseidon MK6
rebreather. This DC produces logs that contain of a .txt file that has
all the meta data and a .csv file that contains the sample readings. The
CSV file is different from the others in that it has a line per each
sample reading at given time. Thus we have to merge all the lines from
one point in time into one sample reading of ours.
[Dirk Hohndel: addressed some compiler warnings]
Signed-off-by: Miika Turkia <miika.turkia@gmail.com>
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
In the transition to the partial pressure helper function,
the water vapor component of the breathing gas had been dropped.
This had a significant effect on deco times for deep dives.
Signed-off-by: Robert C. Helling <helling@atdotde.de>
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
This reports back a error to the user if the firmware update failed.
We should re-wire this to have a log-function that gets called from
libdivecomputer via the context to get an actual error message.
Signed-off-by: Anton Lundin <glance@acc.umu.se>
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
This fixes a copy-paste error, dereferencing the wrong pointer in the
slot that gets called when the firmware update thread has run.
Signed-off-by: Anton Lundin <glance@acc.umu.se>
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
hw_ostc_device_fwupdate was introduced after 0.4.2 so ifdef it to
libdivecomputer >= 0.5.0. The scope of users interested in this feature
probably isn't big enough to justify a bump of our dependencies to a
unreleased version of libdivecomputer.
Signed-off-by: Anton Lundin <glance@acc.umu.se>
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
When dropping to the bottom in plan (and add) mode, the gas label was
placed along the diagonal line from (0,0) to the second dive data point
(i.e. the one at the end of the "at deptch" segment). That looks terrible,
the label needs to be along the segment that we are spending at the
bottom.
This patch fixes that problem.
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
This helper function is used to get a nickname for a dive computer, when
the model information on its own may be ambiguous (ie there may be
multiple dive computers of the same model, and we've nicknamed them by
owner).
However, the helper did completely the wrong thing if it didn't find a
dive computer entry at all due to a missing device ID - it would just
return empty. Which is bogus: it should return the model name, the same
way it does if the nickname is missing.
Signed-off-by: Linus Torvalds <torvalds@linux-foundation.org>
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
This adds a icon to the Vyper config page. The image is taken by me of
my Suunto Vyper. Thats the reason for the quality.
Question: Would it be ok to grab a PR image from Suunto's web page to
use here? If so they got better ones...
Signed-off-by: Anton Lundin <glance@acc.umu.se>
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
We currently don't support update firmware for the OSTC3. Where waiting
for support in libdivecomputer for that, so disable that button for now.
Signed-off-by: Anton Lundin <glance@acc.umu.se>
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
This code connects the final parts of the generic firmware update code.
Signed-off-by: Anton Lundin <glance@acc.umu.se>
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
Normally, all samples have depths associated with them, and most dive
computers likely don't even have the concept of a sample without a depth.
However, the new Suunto EON Steel definitely has samples with just time
updates (and perhaps other data, like events) and no depth at all. We
get unhappy about that, and interpret it as having a zero depth. Which
doesn't look very nice.
This just makes all samples default to the same depth as the previous
sample. For normal samples with a depth value, that will just override
that default.
Signed-off-by: Linus Torvalds <torvalds@linux-foundation.org>
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
-make the dive profile dynamic to check user selected units from the
settings file.
-some of the code needs to be refactored and copied to a more
appropriate location.
Signed-off-by: Gehad elrobey <gehadelrobey@gmail.com>
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
Edit the HTML exporter to export data fields with user selected units.
Signed-off-by: Gehad elrobey <gehadelrobey@gmail.com>
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
Working on HTML exports to support imperial and metric units and also
custom selected units based on subsurface preferences.
User selected units is exported to settings file that will be mainly used
by listlib javascript file.
Signed-off-by: Gehad elrobey <gehadelrobey@gmail.com>
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
The pre-existing tissue load going into a dive can change if the start
time of a dive changes. Therefore we need to recalculate the ceiling when
editing start time (or date) of a dive.
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
While the existing code worked fine for editing that start date or time of
dives downloaded from a dive computer or imported from some other source,
for manually entered dives this did not work and the date or time was
always reset to the original time once the changes were saved.
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
Ensure that there is no (clipped) overflowfrom the header.
Signed-off-by: Giuseppe Bilotta <giuseppe.bilotta@gmail.com>
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
The previous hard-coded solution for GTK+ didn't work on HiDPI, and a
comment hinted that even on Mac OS X it might need tuning. Find a more
generic solution that should work regardless of platform and style,
based purely on the geometries reported by the style itself.
Signed-off-by: Giuseppe Bilotta <giuseppe.bilotta@gmail.com>
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
Also, generate the corresponding pixmap only once, and distribute it to
all models that need it.
Signed-off-by: Giuseppe Bilotta <giuseppe.bilotta@gmail.com>
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
The latest CCR patches had rendered the planner not usable for CCR dives.
This patch corrects this (and reenables the CCR set point column for
segments). The problem was that a new member setpoint of struct divepoint
had been introduced, but there was already po2 which had the same meaning.
This patch merges the two and renames them setpoint to prevent future
confusion.
Signed-off-by: Robert C. Helling <helling@atdotde.de>
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
The OSTC3 stores the pressure sensor offset as a signed 8-bit integer.
Signed-off-by: Anton Lundin <glance@acc.umu.se>
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
This adds the settings not previously available in the OSTC3 settings.
Signed-off-by: Anton Lundin <glance@acc.umu.se>
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
This creates a Advanced settings page for the OSTC3 and moves the deco
settings off to that page.
Signed-off-by: Anton Lundin <glance@acc.umu.se>
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
These settings are gas related so they fitted in the spare space in the
gas screen.
Signed-off-by: Anton Lundin <glance@acc.umu.se>
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>