Commit graph

553 commits

Author SHA1 Message Date
Rick Walsh
8b5c5674b1 VPM-B profile: initialize first_ceiling_pressure
If we don't set first_ceiling_pressure at start of dive, a shallow ceiling can
be shown when it shouldn't be.

Fixes #584

Signed-off-by: Rick Walsh <rickmwalsh@gmail.com>
Signed-off-by: Robert C. Helling <helling@atdotde.de>
2017-10-01 23:58:55 +03:00
Robert C. Helling
1f50485732 More VPMB state in special structure
... and reset deco information in profile ceiling computation.

The planner test then needs to know about the struct holding the deco
state.

Signed-off-by: Robert C. Helling <helling@atdotde.de>
2017-10-01 23:58:55 +03:00
Stefan Fuchs
7713c7e607 Use helper function dive_endtime() where apropriate
Calculating dive.when + dive.duration doesn't always give the correct
endtime of a dive especially when a dive has surface interval(s) in
the middle.
Using the helper function dive_endtime() fixes this issue.

Signed-off-by: Stefan Fuchs <sfuchs@gmx.de>
2017-10-01 23:55:37 +03:00
Miika Turkia
325c4459ad Update sample_start and sample_end pressures
When we merge dives, the sample_start and sample_end pressures are only
used in-memory for displaying data to the user. However, we should
update them as well as this will show the user the correct data in the
equipment/cylinder and i.e. SAC calculation.

Fixes #577

Signed-off-by: Miika Turkia <miika.turkia@gmail.com>
2017-10-01 11:31:18 +03:00
Miika Turkia
2a29d4a4ba Save Subsurface version to libdivecomputer logfile
Signed-off-by: Miika Turkia <miika.turkia@gmail.com>
2017-09-28 08:51:34 +02:00
Rick Walsh
1bc5050eff Planner prefs: set all ascent rates to 9m/min
9m/min (or 10m/min) is the ascent rate assumed by Buhlmann and navy tables,
and the default of most other planning software and dive computers.

Setting the default to 9m/min allows the default behaviour to be consistent
with "expected" behaviour, but does not prevent the user from changing the
preference.  There is disagreement between some users whether the final ascent
ascent duration should be considered when determining the length of the final
stop.  This change does not alter that at all, but at 9m/min, the difference
is <1min.

See #592

Signed-off-by: Rick Walsh <rickmwalsh@gmail.com>
2017-09-28 06:11:51 +02:00
Jan Mulder
f442031fdd BLE: big writes to connected DC (OSTC firmware)
Most writes to a connected DC are small, typically some
command bytes to get DC in download mode, or to set
some parameter. All this just worked over BLE,
however, sending a full firmware update (on an
OSTC device) failed, as the underlying BLE interface
can only handle small 20 byte BLE packets at once.

So, send max ble->packet_size chuncks at once.

Tested for the following cases (linux desktop with
OSTC3 over BLE):
1) normal download of dive data.
2) read and write settings from configure UI
3) update firmware (from 2.15 to 2.15)

And to my surprise, no flow control credit administration
is required here.

Signed-off-by: Jan Mulder <jlmulder@xs4all.nl>
2017-09-22 02:30:58 -07:00
Dirk Hohndel
bb1df1218d BLE support: simplify write function
It seems clearer to bail when list is empty...

Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
2017-09-20 19:19:25 -04:00
Dirk Hohndel
16d9b0c790 DC download: fix 'no new dives' message
Stupidly, commit 731d9dc9bd ("DC download: tell user when no new dives
were found") was missing the conditional when to show that messages.

Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
2017-09-20 18:44:14 -04:00
Robert C. Helling
5b080bedde Remove option to apply GFlow at maxdepth
This option should have never been there. This is not how
gradient factors are supposed to work. It would only trick
users to use the wrong value..

Signed-off-by: Robert C. Helling <helling@atdotde.de>
2017-09-20 08:54:41 -07:00
Robert C. Helling
a6f186279f Add a checkbox to turn off plan variations
... as those come with a performance penalty

Signed-off-by: Robert C. Helling <helling@atdotde.de>
2017-09-20 08:54:41 -07:00
Stefan Fuchs
6a4b44a3d4 Correct comment for deco subsurface_conservatism_factor
This adapts the comment according to the change done in
bd89e33e76

Signed-off-by: Stefan Fuchs <sfuchs@gmx.de>
2017-09-20 08:52:36 -07:00
Dirk Hohndel
753c00a493 BLE on non-Apple OSs: switch back to using BT address
While this interface is deprecated, too much in our existing code depends
on being able to create the QLowEnergyController with just the address.

Additionally, createCentral() is new in Qt 5.7 and therefor this broke
builds on Linux distros that are still on 5.6.

Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
2017-09-17 16:31:07 -07:00
Dirk Hohndel
731d9dc9bd DC download: tell user when no new dives were found
Otherwise it almost looks like something went wrong with the download.

Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
2017-09-17 14:46:44 -07:00
Dirk Hohndel
90d73924c2 BLE: try to pick the correct descriptor to write to
The ordering on Mac appears to be random, but after looking through the
various successful logs of BLE downloads, it seems we always wrote to the
ClientCharacteristicConfiguration descriptor. So try to find that one first,
and only grab the first descriptor in the list if we didn't find a
ClientCharacteristicConfiguration descriptor.

Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
2017-09-17 09:58:11 -07:00
Dirk Hohndel
26e610c3f4 BLE: create controller from QBtDeviceInfo
Creating it from an address is a) deprecated and b) impossible on Mac or iOS.

Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
2017-09-17 09:58:11 -07:00
Dirk Hohndel
db38a7023d BLE: helper function to get QBtDeviceInfo from UUID
Right now this will only work if you scan for your BLE dive computer every
time. Ideally we should simply initiate a scan and look for that address if
it's not found in the hash.

Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
2017-09-17 09:57:57 -07:00
Dirk Hohndel
5695ef956b BLE: if there's no address, use the UUID instead
This is not just for IOS, the same applies on a Mac. But I see
no issue with enabling that for all OSs.

Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
2017-09-17 09:54:04 -07:00
Seppo Takalo
a2a1dfdf9f Use dive ID instead of dive number when importing from Shearwater db
Dive IDs are unique but same dive number can appear multiple times within
the same database. This can happen for example when user changes the
"next log number" from his computer.

Signed-off-by: Seppo Takalo <seppo.takalo@iki.fi>
2017-09-15 08:57:03 -07:00
Seppo Takalo
f7db0c705b Convert usage of atof() to strtod_flags()
The provided strod_flags(str, 0, 0) should work as a drop in replacement
for atof() but does not care about locales which may cause atof() to fail.

strtod_flags() would allow checking of conversion result, but I did not
change the existing logic. This was just regexp search&replace change
to get rid of atof(). I use flags 0 to get more relaxed conversion.

Fixes #574

Signed-off-by: Seppo Takalo <seppo.takalo@iki.fi>
2017-09-15 08:57:03 -07:00
Linus Torvalds
e94af2c0b7 Properly clear sensor pressure data for synthetic plotinfo entries
We only cleared the first sensor data when we created new synthetic plot
info entries, because we only used to have one (well, we had the o2
data, but apparently nobody ever noticed that it didn't get properly
interpolated, probably because people who have CCR dives with o2
pressures are few, and the pressure drops are gradual anyway).

Clear all the pressure data, so that the interpolation code doesn't
think we have some existing real sensor data for the plot info entries
in between proper sample entries.

Signed-off-by: Linus Torvalds <torvalds@linux-foundation.org>
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
2017-09-15 16:29:00 +02:00
Linus Torvalds
41bbae31f5 xml: save the right sensor pressure when we have multiple sensor readings
The XML saving code got the multi-sensor case completely wrong, because
it still had one place where it would always save the first pressure,
rather than the pressure from the right sensor.

This was hidden by the fact that old data would be saved using the
legacy model that only ever used the first sensor slot.  Only if you
actually had multiple sensor slots used would the bug trigger.

Signed-off-by: Linus Torvalds <torvalds@linux-foundation.org>
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
2017-09-15 16:28:07 +02:00
Miika Turkia
a8ce78bf77 Refine cylinder usage tests
Consider cylinder used also if the first and last sample pressure differ
enough

Signed-off-by: Miika Turkia <miika.turkia@gmail.com>
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
2017-09-14 07:33:55 +02:00
Linus Torvalds
6769e21441 Make the info window show all the pressures we have
We used to only show the first pressure we had, from back when we only
supported a single sensor.

Reported-by: Stefan Fuchs <sfuchs@gmx.de>
Signed-off-by: Linus Torvalds <torvalds@linux-foundation.org>
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
2017-09-13 14:05:26 -07:00
Miika Turkia
5afa5ed9f1 Detect dive mode on Shearwater DB import
Signed-off-by: Miika Turkia <miika.turkia@gmail.com>
2017-09-13 14:04:31 -07:00
Seppo Takalo
850917d41d Don't assume CCR mode when importing from Shearwater
Logic was assuming CCR mode if field "averagePPO2" was present.

Signed-off-by: Seppo Takalo <seppo.takalo@iki.fi>
2017-09-13 07:57:45 -07:00
Seppo Takalo
ba854a8cc5 Fix cylinder changes when importing from Shearwater database
Re-do the logic to use add_gas_switch_event() instead of creating event
manually.

Fix the SQL query to find the proper dive id from dive log number.

Signed-off-by: Seppo Takalo <seppo.takalo@iki.fi>
2017-09-13 07:57:45 -07:00
Seppo Takalo
83c9ad35a6 Fix Shearwater cylinder detection logic
Fix the SQL query to find proper dive id instead of assuming log number to
be the same as id.

Signed-off-by: Seppo Takalo <seppo.takalo@iki.fi>
2017-09-13 07:57:45 -07:00
Seppo Takalo
6509f2ed9f Ignore missing pressure values when importing from Shearwater
Shearwater seems to report missing AI sensors as a pressure reading
4092 (raw) which is 564 bar.

Signed-off-by: Seppo Takalo <seppo.takalo@iki.fi>
2017-09-13 07:57:45 -07:00
Miika Turkia
e25cecf37c Inform user if there was no dive profile in DL7/ZXU file
Signed-off-by: Miika Turkia <miika.turkia@gmail.com>
2017-09-11 07:21:43 -07:00
Miika Turkia
40cc0b0e4b Import dive number from DL7 log
Signed-off-by: Miika Turkia <miika.turkia@gmail.com>
2017-09-11 07:21:43 -07:00
Miika Turkia
5b5cab2905 Do not merge dives with zero duration
As these are probably manually entered dives with incomplete data, it is
better not to merge them.

See #561

Signed-off-by: Miika Turkia <miika.turkia@gmail.com>
2017-09-11 07:19:57 -07:00
Miika Turkia
25fc72e22f Do not save non-existent time
Note that git storage still encodes the time into file name.

Signed-off-by: Miika Turkia <miika.turkia@gmail.com>
2017-09-11 07:19:57 -07:00
Miika Turkia
d7c89a79f8 Do not save duration if it is zero
See #561
2017-09-11 07:19:57 -07:00
Miika Turkia
15ef53fb80 Do not save heartbeat to XML if it has not changed
Signed-off-by: Miika Turkia <miika.turkia@gmail.com>
2017-09-11 07:19:57 -07:00
Miika Turkia
643085f992 Do not save bearing to XML if it has not changed
Signed-off-by: Miika Turkia <miika.turkia@gmail.com>
2017-09-11 07:19:57 -07:00
Dirk Hohndel
9576a9ba8a Add Cochran dive computers to FTDI list
Based on information from John Van Ostrand <john@vanostrand.com>.

Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
2017-09-06 08:35:39 -07:00
John Van Ostrand
866a25f90e Implemented serial_set_break for FTDI
Setting break is required to wake up Cochran DCs (it doesn't make
sense to me, but it's needed).

Signed-off-by: John Van Ostrand <john@vanostrand.com>
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
2017-09-06 08:30:48 -07:00
John Van Ostrand
166eb17ac2 Changed serial_ftdi flush to a reset if DC_DIRECTION_ALL
The USB reset flushes both buffers, but it also solves a problem
waking up a Cochran DCs.

Signed-off-by: John Van Ostrand <john@vanostrand.com>
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
2017-09-06 08:30:40 -07:00
John Van Ostrand
928621357c Changed backoff strategy for short reads.
Back off was exponential starting at 10ms, which for high baud
rate and no flow-control connections might cause buffer overrun.
This was causing problems when reading Cochran DCs, the hearbeat
byte was being missed.

Signed-off-by: John Van Ostrand <john@vanostrand.com>
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
2017-09-06 08:30:21 -07:00
Jan Mulder
9a2d503d3b Unify credential states
Having two different enums around with more or less the same
definition has lead to unclear code. After removing two not needed
states on the mobile end, the remaining step to one enum for the
credential state becomes almost is simple rename operation.

Unfortunately, I do not know a way to embed a plain C enum
from pref.h into the QMLManager object. So after this, there
are still 2 enums around, but now identical.

This commit is not changing any functionality.

Signed-off-by: Jan Mulder <jlmulder@xs4all.nl>
2017-09-04 07:38:30 -07:00
Marc Arndt
48ff047086 adding comments as advised 2017-08-29 06:50:18 -07:00
Marc Arndt
90b9b61ba3 fixing indentation 2017-08-29 06:50:18 -07:00
Marc Arndt
ac7e60b456 Ignore Divesoft Button Press Events
Prevent button press events from showing on the profile
graph when we import divesoft DLF files.

Reported-by: Marc Arndt
Signed-off-by: Marc Arndt <marc@marcarndt.com>
2017-08-29 06:50:18 -07:00
Robert C. Helling
aed5b7d267 Show variations in Runtime string
Signed-off-by: Robert C. Helling <helling@atdotde.de>
2017-08-29 06:49:44 -07:00
Robert C. Helling
2832141d2c Compute variations of plans
Print out partial derivatives of stop times with respect to
variation of depth and duratin of last manual segment.

Signed-off-by: Robert C. Helling <helling@atdotde.de>
2017-08-29 06:49:44 -07:00
Robert C. Helling
e6545a7b0f Store a table of deco stops in planner
... in addition to struct diveplan which combines all kinds
of information

Signed-off-by: Robert C. Helling <helling@atdotde.de>
2017-08-29 06:49:44 -07:00
Robert C. Helling
456e2cec89 Cache all Buehlmann factors
not just the last one.

Signed-off-by: Robert C. Helling <helling@atdotde.de>
2017-08-29 06:49:44 -07:00
Robert C. Helling
515b7b5fea Allow for o2 breaks in binary search stop time finder
Signed-off-by: Robert C. Helling <helling@atdotde.de>
2017-08-29 06:49:44 -07:00
Robert C. Helling
33fa336be6 Find deco stop time by binary search instead of iteration
This allows to go to much smaller granularity without severe
performance penalty. It should also increase performance for
long decompression times.

Currently this leads to missing cached tissue factors, the caching
has to be adopted to this.

Also, for the time being this breaks the bottom gas breaks feature.

Signed-off-by: Robert C. Helling <helling@atdotde.de>
2017-08-29 06:49:44 -07:00