fake_dc() used to return a statically allocated dc with statically
allocated samples. This is of course a questionable practice in
the light of multi-threading / resource ownership. Once these
problems were recognized, the parameter "alloc" was added. If set
to true, the function would still return a statically allocated
dc, but heap-allocated samples, which could then be copied in
a different dc.
All in all an ownership nightmare and a recipie for disaster.
The returned static dc was only used as a pointer to the samples
anyway. There are four callers of fake_dc() and they all have access
to a dc-structure without samples. Therefore, change the semantics
of fake_dc() to fill out the passed in dc. If the caller does
not care about the samples, it can simply reset the sample number
to zero after work.
Signed-off-by: Berthold Stoeger <bstoeger@mail.tuwien.ac.at>
This function looks for the last gas change before a
given time. We should initialize it with a gaschange
event as we might later use this event to read a
gasmix from it.
Signed-off-by: Robert C. Helling <helling@atdotde.de>
Identify segements that fullfill the folllowing criteria for
the leading compartment:
He is off-gasing while N2 is on-gasing
Overall there is on-gasing
Add a line to the info box for those segments
Signed-off-by: Robert C. Helling <helling@atdotde.de>
get_dive_date_c_string() and get_current_date() return copied strings.
Make this explicit by returning non-const pointers.
Signed-off-by: Berthold Stoeger <bstoeger@mail.tuwien.ac.at>
Previous taglist_get_tagstring signature/implementation did not allow
handling of cases where inputted buffer could not contain all tags.
New implementation allocates buffer based on pre-computed size allowing to
insert all tags in the returned string.
Added get_taglist_string in qthelper to handle conversion to QString
Added TestTagList with tests for taglist_get_tagstring
Signed-off-by: Jeremie Guichard <djebrest@gmail.com>
Make arguments to set_informational_units(), set_git_prefs(),
set_userid(), dive_remove_picture() and update_event_name()
"const char *" for consistency with the rest of core/dive.c.
This will allow replacing toUtf8().data() with the constData()
version in a subsequent commit.
Signed-off-by: Berthold Stoeger <bstoeger@mail.tuwien.ac.at>
The hash field in the picture-structure was in principle non-operational.
It was set on loading, but never actually changed. The authoritative
hash comes from the filename->hash map.
Therefore, make this explicit by removing the hash field from the
picture structure.
Instead of filling the picture structure on loading, add the
hash directly to the filename->hash map. This is done in the
register_hash() function, which does not overwrite old entries.
I.e. the local hash has priority over the save-file. This
policy might be refined in the future.
Signed-off-by: Berthold Stoeger <bstoeger@mail.tuwien.ac.at>
Change the strategy when to allow cylinder removal from a dive:
- Not remove when cylinder has gas switch events, in any other cases
allow removal
- Remove this whole "cylinder with same gas" thing being a criteria
for cylinder removal
When removing a cylinder which has corresponding pressure info in
samples, also remove this pressure info from the samples.
Signed-off-by: Stefan Fuchs <sfuchs@gmx.de>
Remove the global error buffer and pass the error string directly
to the frontend. The frontend is then responsible for accumulating
errors.
Signed-off-by: Berthold Stoeger <bstoeger@mail.tuwien.ac.at>
Move the above function from plannernotes.c to dive.c so that
it is available to be called from the dive log part of the
software, and not only from the planner. The following was done:
1) Edit the comment above the code to make it more accurate
2) Move the structure icd_data to dive.h
3) Create an external reference in dive.h for the above function
4) Copy the body of isobaric_counterdiffusion() to dive.c
Signed-off-by: Willem Ferguson <willemferguson@zoology.up.ac.za>
This patch allows the planner to save the last manually-entered
dive planner point of a dive plan. When the plan has been saved
and re-opened for edit, the time of the last-entered dive planner
point is used to ensure that dive planning continues from the same
point in the profile as was when the original dive plan was saved.
Mechanism:
1) In dive.h, create a new dc attribute dc->last_manual_time
with data type of duration_t.
2) In diveplanner.c, ensure that the last manually-entered
dive planner point is saved in dc->last_manual_time.
3) In save-xml.c, create a new XML attribute for the <divecomputer>
element, named last-manual-time. For dive plans, the element would
now look like:
<divecomputer model='planned dive' last-manual-time='31:17 min'>
4) In parse-xml.c, insert code that recognises the last-manual-time
XML attribute, reads the time value and assigns this time to
dc->last_manual_time.
5) In diveplannermodel.cpp, method DiveplannerPointModel::loadfromdive,
insert code that sets the appropriate boolean value to dp->entered
by comparing newtime (i.e. time of dp) with dc->last_manual_time.
6) Diveplannermodel.cpp also accepts profile data from normal dives in
the dive log, whether hand-entered or loaded from dive computer. It
looks like the reduction of dive points for dives with >100 points
continues to work ok.
The result is that when a dive plan is saved with manually entered
points up to e.g. 10 minutes into the dive, it can be re-opened for edit
in the dive planner and the planner re-creates the plan with manually
entered points up to 10 minutes. The rest of the points are "soft"
points, shaped by the deco calculations of the planner.
Improvements: Improve code for profile display in dive planner
This responds to #1052.
Change load-git.c and save-git.c so that the last-manual-time is
also saved in the git-format dive log.
Several stylistic changes in text for consistent C source code.
Improvement of dive planner profile display:
Do some simplification of my alterations to diveplannermodel.cpp
Two small style changes in planner.c and diveplannermodel.cpp
as requested ny @neolit123
Signed-off-by: Willem Ferguson <willemferguson@zoology.up.ac.za>
There are ca. 50 constructs of the kind
same_string(s, "")
to test for empty or null strings. Replace them by the new helper
function empty_string().
Signed-off-by: Berthold Stoeger <bstoeger@mail.tuwien.ac.at>
Make functions in core/file.c, core/parse.c and core/import-csv.c
that were not used outside their translation unit of static linkage.
parse_date is moved from core/file.c to core/import-csv.c, since it
is used only there.
Signed-off-by: Berthold Stoeger <bstoeger@mail.tuwien.ac.at>
downloadTable was declared twice in "dive.h". Remove one occurence.
Moreover, "uemis-downloader.c" also declared downloadTable. This can
likewise be removed, because "uemis-downloader.c" indirectly includes
"dive.h".
Signed-off-by: Berthold Stoeger <bstoeger@mail.tuwien.ac.at>
All users of autogroup are clearly expecting a boolean value, so
let the type reflect this.
Signed-off-by: Berthold Stoeger <bstoeger@mail.tuwien.ac.at>
clear_vpmb_state() was declared with incorrect signature, and all
functios in this change are extern, so declare them as such.
Signed-off-by: Jan Mulder <jlmulder@xs4all.nl>
For UI responsiveness, we need to be able to run the planner in the background. This needs the
planner state to be localized (and we need to pass a pointer around).
In order to not let too many lines overrun (and to save typing in the future)
I have renamed instances of struct deco_state to ds. Yes this should have gone
to a separate commit but I accidentally commit --amend'ed it.
Computing of planner variations is temporarily disabled.
Unlock the planner when returning early
So we don't deadlock in add dive and recreational mode (which
use the planner without actually planning).
Signed-off-by: Robert C. Helling <helling@atdotde.de>
In general, the C++-side of the preferences code consistently uses
the bool data type for boolean settings. There are five exceptions,
which use short instead:
showPo2
showPn2
showPhe
saveUserIdLocal
displayInvalidDives
This patch attempts to make the code more consistent by turning
these into bools as well.
Tests showed that writing as short and reading as bool is handled
gracefully by the Qt variant code. Therefore, an upgrade should not
cause user-visible changes to their settings.
As a bonus, two extern declarations of the set_save_userid_local()
function, which is not defined anywhere, were removed.
Signed-off-by: Berthold Stoeger <bstoeger@mail.tuwien.ac.at>
Commit d6c013f303 introduced a cast to avoid a signed/unsigned
comparison warning for all translation units that included
core/dive.h.
Commit 1f8506ce64 then changed the definition of duration_t from
unsigned to signed, inverting the effect of d6c013f303.
Thus, revert d6c013f303 to allow compilation with -Wall without
flooding.
Signed-off-by: Berthold Stoeger <bstoeger@mail.tuwien.ac.at>
It's already used in core/gaspressures.c where it was declared
privately, and we'll have a new user in the profile code, so just
declare it in a proper header file like it should have been.
Signed-off-by: Linus Torvalds <torvalds@linux-foundation.org>
Type duration_t changed from uint to int.
Default value of '-1' introduced for some of the values in struct sample:
NDL used -1 as default.
Bearing uses -1 as default (no bearing set).
Display pXX, EAD, END, density, MOD only if values are larger than 0.
In profile don't display data from two first and two last plot_data
entries in info box.
Signed-off-by: Stefan Fuchs <sfuchs@gmx.de>
I'm sure this bug has heen here forever, but the CNS clock is
not very relevant for most divers, and even some technical divers
do not care about this value.
However, doing long decompression dives, the value can easily
grow over 100%, and a lot further. For example, the OSTC computers
use 2 bytes to store the CNS value in the profile data, and I
have multiple dives in my logbook going way over 255%.
This all said. Just store the CNS value in an unsigned 16 bit.
Signed-off-by: Jan Mulder <jlmulder@xs4all.nl>
This makes the calculations in profile.c a little simpler, especially now we
adopt consistent final ascent rate to determine deco_time since d15779a27
Signed-off-by: Rick Walsh <rickmwalsh@gmail.com>
Currently one has to explicitly use --win32console and/or
--win32log to enable a dedicated console (a console window
that opens next to the Subsurface window) or to enable file
logging on Win32.
This patch makes the following changes:
- removes the --win32* command line arguments
- removes the dedicated console window support
- if the app starts from a shortcut and not from a console, always
redirect stderr and stdout to _err & _out log files
- if the app starts from a console redirect stderr and stdout to that
console
Signed-off-by: Lubomir I. Ivanov <neolit123@gmail.com>
That's not a standard functions, so let's just build it. This is not
the most efficient way to write it, but it will do.
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
This line:
dc = &dive->dc
can SIGSEGV for a NULL 'dive' pointer.
return NULL if 'dive' is NULL.
Also handle NULL 'dc' in get_gasmix() and set 'ev' to NULL.
Signed-off-by: Lubomir I. Ivanov <neolit123@gmail.com>
current_dc is a macro that determines the dive computer
based on the current dive number. When the planner is started
from an emtpy dive list, the dive number ends up being -1 and
that doesn't produce a valid dive computer. Use the divecomputer
of the displayed_dive instead. This is done via a macro that
can also be used in two other places. Without this patch, the
planner crashed when called on an empty dive list.
Signed-off-by: Robert C. Helling <helling@atdotde.de>
When changing the date/time of a dive in the planner the dive may end
up in a totaly new position in respect to date/time of other dives in
dive list table. It can be moved to the past or the future before or after
other existing dives. It also could overlap with an existing dive.
This change enables identification of a new "virtual" dive list position
and based on this starts looking for previous dives.
Then it (as before the change) does init the deco calculation with any
applicable previous dive and surface interval.
If some of these applicable dives overlap it returns a neg. surface time
which is then used in the planner notes to prohibit display of results.
Signed-off-by: Stefan Fuchs <sfuchs@gmx.de>
In the planner if one adds two or more cylinders with the same gasmix
(e.g. back gas and bottom stage 18/45) the drop down and data in the
used gas column of the planner points table will be filled with a more
verbose string mentioning also the cyl number and the cyl type
description.
Makes it easier in such a case to select the right cylinder.
Introduces also a helper function which tells you if there is another
cylinder with the same gasmix as the provided cylinder.
This also has an option if it should consider unused cylinders or not.
Signed-off-by: Stefan Fuchs <sfuchs@gmx.de>
The more I looked at the code that added the country to the dive site,
the more it seemed redundant given what we have with the taxonomy.
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
... and reset deco information in profile ceiling computation.
The planner test then needs to know about the struct holding the deco
state.
Signed-off-by: Robert C. Helling <helling@atdotde.de>
This option should have never been there. This is not how
gradient factors are supposed to work. It would only trick
users to use the wrong value..
Signed-off-by: Robert C. Helling <helling@atdotde.de>