Commit graph

246 commits

Author SHA1 Message Date
Robert C. Helling
6b0ecb012d Place divemode changes in submenu of context menu
Also unify the repeated code in slots.

Signed-off-by: Robert C. Helling <helling@atdotde.de>
2018-05-14 23:47:00 +03:00
Willem Ferguson
718f9811b7 Show divemode swith options only for rebreather dives
The dive profile context menu gets rather long with three
additional divome switches that can be selected. This is now changed
so that the additional options are only shown when in CCR
or in PSCR divemode.

Signed-off-by: Willem Ferguson <willemferguson@zoology.up.ac.za>
2018-05-14 23:47:00 +03:00
Willem Ferguson
e46cb2f800 Create divemode switches using profile context menu
Allow the manual creation of divemode switch events using the
profile context menu.

Signed-off-by: Willem Ferguson <willemferguson@zoology.up.ac.za>
2018-05-14 23:47:00 +03:00
Willem Ferguson
b9174332d5 Read and write divemode changes (xml and git)
This provides for reading of divemode change events from dive logs
and for writing them to dive logs. This applies to xml and git
divelogs. Divemode change events have the following structure:
event->name = "modechange"
event->value = integer corresponding to enum dive_comp_type (dive.c),
reflecting the type of divemode change (OC, CCR, PSCR, etc).

In the dive log file, the event value is written as a string that
corresponds to each of the enum values, e.g.
<event name='modechange' divemode='OC' />
This xml is also read from the dive log file and translated to an
appropriate value of event->value.

The file diveeventitem.cpp was udated to reflect this new way of
dealing with divemode change events.

Signed-off-by: Willem Ferguson <willemferguson@zoology.up.ac.za>
2018-05-14 23:47:00 +03:00
Willem Ferguson
5f95c226ef Provide icons for bailout events on the dive profile.
Signed-off-by: Willem Ferguson <willemferguson@zoology.up.ac.za>
2018-05-14 23:47:00 +03:00
Dirk Hohndel
ea83b5ed37 Core: remove dive.h from files that don't need it
Of course, quite a few of them indirectly get it through other header
files.

Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
2018-05-14 10:13:39 -07:00
Dirk Hohndel
d577467f97 Core: introduce new subsurface-string header
First small step to shrinking dive.h.

Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
2018-05-14 10:13:39 -07:00
Berthold Stoeger
c71a5d7413 Dive pictures: Don't update all pictures on drag & drop to profile
In the old code, we used to reload the whole picture list on drag & drop
to the profile. Instead, only update the drag&dropped picture and repaint
the profile-pictures.

Signed-off-by: Berthold Stoeger <bstoeger@mail.tuwien.ac.at>
2018-05-13 13:52:35 -07:00
Berthold Stoeger
630862971f Dive pictures: remove close-button optimization
One close-button object was used for all dive pictures. This seems
like a brittle premature optimization and the pixmap is shared
anyway. Make the button a subobject of the dive picture object.

Change the object-hierarchy to be based on QGraphicsItem instead
of QObject. The QObject here is only used as a kludge to support
signals and properties (the latter are necessary for animations).

Remove a comment, which does not seem to be relevant after this
change.

Signed-off-by: Berthold Stoeger <bstoeger@mail.tuwien.ac.at>
2018-05-13 13:52:35 -07:00
Willem Ferguson
70bb4c145b Fix CCR setpoint display bug
1) The connection for the display of CCR-setpoint o2SetpointGasItem
   was erroneous, being connected to partialpressuregasSettings. It
   is now correctly connected to technicalDetailsSettings.
2) The colour of the setpoint graph is changed from PO2_ALERT (red) to
   an orange colour in order to show setpoint in red only when it
   exceeds 1.6. This emphasises the visibility of red parts of the
   gas pressure graphs whenever gas limits are exceeed.

Signed-off-by: Willem Ferguson <willemferguson@zoology.up.ac.za>
2018-05-07 13:56:23 +02:00
Berthold Stoeger
920ff15f71 Planner: don't return static data in fake_dc()
fake_dc() used to return a statically allocated dc with statically
allocated samples. This is of course a questionable practice in
the light of multi-threading / resource ownership. Once these
problems were recognized, the parameter "alloc" was added. If set
to true, the function would still return a statically allocated
dc, but heap-allocated samples, which could then be copied in
a different dc.

All in all an ownership nightmare and a recipie for disaster.
The returned static dc was only used as a pointer to the samples
anyway. There are four callers of fake_dc() and they all have access
to a dc-structure without samples. Therefore, change the semantics
of fake_dc() to fill out the passed in dc. If the caller does
not care about the samples, it can simply reset the sample number
to zero after work.

Signed-off-by: Berthold Stoeger <bstoeger@mail.tuwien.ac.at>
2018-05-07 13:11:53 +03:00
Berthold Stoeger
fb84b11854 Profile: Fix crash on addition of dive to fresh logbook
If there is no current dive, the macro current_dc returns NULL.
This led to a null-pointer dereference.

Reported-by: Martin Měřinský <mermar@centrum.cz>
Signed-off-by: Berthold Stoeger <bstoeger@mail.tuwien.ac.at>
2018-05-03 02:14:03 +03:00
Willem Ferguson
81a812539c Plot OC-pO2 graph for SCR dives
This commit allows plotting the OC-equivalent pO2 graph for PSCR
dives. This happens in both the cases where there is no external
O2-monitoring AND when there is external pO2 monitoring. The
calculations are only done for PSCR dives and is achieved as
follows:

1) Within plot-info create a pressure-t called OC_pO2 in
   profile.h and populate this variable with the open-circuit
   pO2 values in profile.c.
2) Create a new partialPressureGasItem ocpo2GasItem in
   profilewidget2.h and, in profilewidget2.cpp, initialise it
   to read the plot-info OC_pO2 values and enable its
   display by using the setVisible method. The
   diveplotdatamodel was also touched in order to achieve
   this.
3) Create a pref button that controls the display of OC-pO2 for SCR dives
4) Change the colour of the OC-pO2 grpah to orange
5) Change the connection of the crr_OC_pO2 signal to be appropriate
6) rename the OC_pO2 attribute to scr_OC-pO2

Signed-off-by: Willem Ferguson <willemferguson@zoology.up.ac.za>
2018-04-28 20:11:22 +03:00
Berthold Stoeger
36249f2780 Profile: Conditionally compile pictures-vector on mobile.
This vector is not used on mobile and cause iOS compilation to fail.

Signed-off-by: Berthold Stoeger <bstoeger@mail.tuwien.ac.at>
2018-04-09 11:29:14 -07:00
Berthold Stoeger
f1830cd44e Profile: On dataChanged() only update pictures that actually changed
Only update those pictures of the DivePictureModel that actually changed.
This will be useful once pictures are loaded incrementally.

To do so, replace the pictures array by an array with stable ids. Before
this commit, not-shown pictures are left out of the pictures array, which
makes the mapping from DivePictureModel-ids to the picture array index
non-trivial.

Replace the QList<DivePictureItem *> by a std::vector<std::unique_ptr<DivePictureItem>>
to ease memory management. Sadly, owing to COW semantics, QVector is incompatible
with QScopedPointer.

Signed-off-by: Berthold Stoeger <bstoeger@mail.tuwien.ac.at>
2018-04-09 07:50:21 -07:00
Stefan Fuchs
b38eb45b29 Profile heartrate: Nicer min/max values and tic distance
Correct a bug in finding the minimum heartrate.

Use the minimum and maximum heartrate value to set min/max and
tic distance for the heartrate axis in the profile.

Signed-off-by: Stefan Fuchs <sfuchs@gmx.de>
2018-03-19 15:44:02 -07:00
Berthold Stoeger
b72cc1f317 Cleanup: consistently use qPrintable()
Replace constructs of the kind
  s.toUtf8().data(),
  s.toUtf8().constData(),
  s.toLocal8Bit().data(),
  s.toLocal8Bit.constData() or
  qUtf8Printable(s)
by
  qPrintable(s).

This is concise, consistent and - in principle - more performant than
the .data() versions.

Sadly, owing to a suboptimal implementation, qPrintable(s) currently
is a pessimization compared to s.toUtf8().data(). A fix is scheduled for
new Qt versions: https://codereview.qt-project.org/#/c/221331/

Signed-off-by: Berthold Stoeger <bstoeger@mail.tuwien.ac.at>
2018-03-14 13:55:36 +02:00
Stefan Fuchs
aacc688670 Use correct numeric format based on selected locale (Qt domain part)
This changes the numeric format of many values printed to the UI to
reflect the correct numeric format of the selected locale:
- dot or comma as decimal separator
- comma or dot as thousands separator

In the Qt domain the `L` flag is used case specific mostly
in qthelper.cpp.
Then the helper functions get_xxx_string() are used more consistently.

Signed-off-by: Stefan Fuchs <sfuchs@gmx.de>
2018-03-05 16:28:18 +01:00
Stefan Fuchs
95a23cf470 Use temperature_t for temperatures in struct stats_t
Use struct temperature_t for temperatures in struct stats_t and
use get_temperature_string() when printing these temperatures for
statistics and HTML export.

Signed-off-by: Stefan Fuchs <sfuchs@gmx.de>
2018-02-24 11:45:17 -08:00
Stefan Fuchs
a7372d9340 Remove space between pressure value and pressure unit in profile
Bring one more value plus unit pair which is the pressure value printed
in the profile in accordance with the coding style/UI style rule of
not having a space between value and unit.

Signed-off-by: Stefan Fuchs <sfuchs@gmx.de>
2018-02-22 21:48:05 +02:00
Berthold Stoeger
5c248d91cd Coding-style: remove superfluous parentheses
Mostly replace "return (expression);" by "return expression;" and one
case of "function((parameter))" by "function(parameter)".

Signed-off-by: Berthold Stoeger <bstoeger@mail.tuwien.ac.at>
2018-02-17 19:38:52 -08:00
Stefan Fuchs
b5ce06c8b9 Free various struct membuffer in different functions
Signed-off-by: Stefan Fuchs <sfuchs@gmx.de>
2018-02-02 11:29:55 -08:00
Jan Mulder
20dc6a31f4 profile: replot handles while planning
The settingsChanged() function of the profile widget tries to be
clever and tries to prevent not needed replots of the profile.
I'm not sure this is very relevant in the first place as change
of settings are almost instantly, with or without replot. It
appears that replot is always executed when there are
calculated ceilings visible. But without calculated ceilings
a replot is "optimized out". This does, however, introduce dangling
divehandles in PLAN/EDIT and ADD mode of the profile, when
any setting that influences the y-axis is changed.

The fix is trivial. Just force a replot in the PLAN/EDIT and ADD
modes.

Fixes: #1070

Signed-off-by: Jan Mulder <jlmulder@xs4all.nl>
2018-01-31 14:48:31 +01:00
Willem Ferguson
b9ac89574e Planner: print icd information at 0.1 resolution
The gas fractions (in %) are now printed at a resolution of 0.1%
and not at 0.01% as previously.

The string in the info box that provides icd data is reformatted
so that the info-box is as narrow as possible.

Signed-off-by: Willem Ferguson <willemferguson@zoology.up.ac.za>
2018-01-24 22:03:42 +01:00
Jan Mulder
36cfab46bd profile: fix weird disappearance of cylinder pressure line
The reason for this issue, and fix for this is very similar
to commit b4d37e8ee. Just set both recalculate flags on a mouse
release event, so that the cylinder pressure line is recalculated.

Signed-off-by: Jan Mulder <jlmulder@xs4all.nl>
2018-01-24 16:19:19 +01:00
Stefan Fuchs
d5cb30efac Profile info box ICD: Change format of ICD string
Change the format from (example!)
ICD: ΔHe=-34% ΔN₂=3%<3%
to
ICD: ΔHe=-34% ΔN₂=+3%<+2.8%

Change strings given to translation to less complex ones.

Signed-off-by: Stefan Fuchs <sfuchs@gmx.de>
2018-01-21 18:01:56 +01:00
Robert C. Helling
c89cfcccbe Only give ICD warning if pN2 increases
as otherwise there are warning on the descent.

The ICD line in the info box is generated for all
gas switches with decreasing He content.

Also change the presentation in the info box to align it
with the notes.

Signed-off-by: Robert C. Helling <helling@atdotde.de>
2018-01-21 15:24:46 +01:00
Robert C. Helling
d029feb2d5 Show ICD in gaschange icons
Add an exclamation mark in the gas change icons if
the change violates our isobaric counter diffusion
criterium.

Signed-off-by: Robert C. Helling <helling@atdotde.de>
2018-01-21 15:24:46 +01:00
Robert C. Helling
7b508e41cd Show ICD events data in infobox
If a gas switch violates our ICD criteria, show
this in the info box.

Signed-off-by: Robert C. Helling <helling@atdotde.de>
2018-01-21 15:24:46 +01:00
Jan Mulder
b4d37e8eeb profile: fix garbled profiles after visiting the planner
See mentioned GitHub issue for the full issue, and images.

The reason for this weird behavior is the existence of 2 flags in
the profile code: shouldCalculateMaxTime and shouldCalculateMaxDepth.
When exactly following the use case and test data as attached to
the GitHub issue (a very short dive, shorter than most of the
dives in the logbook), the shouldCalculateMaxTime flag never got
back to its true status, causing the the time scale not to adapt
to other dives when just clicking (or selecting) them from the dive
list.

The problem is fixed here by also setting the shouldCalculateMaxTime
flag on manipulating wayppoints in the dive plan.

Fixes: #1039

Signed-off-by: Jan Mulder <jlmulder@xs4all.nl>

Signed-off-by: Jan Mulder <jlmulder@xs4all.nl>
2018-01-12 10:26:05 -08:00
Berthold Stoeger
e85ecdd925 Introduce helper function empty_string()
There are ca. 50 constructs of the kind
  same_string(s, "")
to test for empty or null strings. Replace them by the new helper
function empty_string().

Signed-off-by: Berthold Stoeger <bstoeger@mail.tuwien.ac.at>
2018-01-11 06:07:13 +01:00
Jan Mulder
34bc4fc0af Pictures tied to profile are not supported on mobile
Move divepicturemodel.cpp to the desktop only category and deal
with the (limited) fallout. We, currently, do not support dive
pictures tied to the profile on mobile, so there is no use
including this code.

Signed-off-by: Jan Mulder <jlmulder@xs4all.nl>
2018-01-10 21:28:02 +01:00
Jan Mulder
9c01315d31 Un-tie plannner model from profile on mobile
Do not pull in the DivePlannerPointsModel::instance as this is not
used in the called function. We (currently) do not support deco
computations on mobile, so trying to pull in any deco state from
the planner is futile anyway.

With this uncoupling, 6 more model files are not needed in mobile
any more.

Signed-off-by: Jan Mulder <jlmulder@xs4all.nl>
2018-01-10 21:28:02 +01:00
Berthold Stoeger
14e6c132c8 Typo: Threshould -> Threshold
Signed-off-by: Berthold Stoeger <bstoeger@mail.tuwien.ac.at>
2018-01-10 21:25:02 +01:00
Berthold Stoeger
85ac3106e6 Typo: indice -> index
Signed-off-by: Berthold Stoeger <bstoeger@mail.tuwien.ac.at>
2018-01-10 21:25:02 +01:00
Berthold Stoeger
d9ac716162 Replace CREATE_PP_GAS macro by member function in profilewidget2.cpp
Signed-off-by: Berthold Stoeger <bstoeger@mail.tuwien.ac.at>
2018-01-10 21:25:02 +01:00
Berthold Stoeger
05974d17c9 Remove two arguments from ProfileWidget2::setupItem()
1) hAxis was always set to timeAxis
2) model was always set to dataModel

Signed-off-by: Berthold Stoeger <bstoeger@mail.tuwien.ac.at>
2018-01-10 21:25:02 +01:00
Berthold Stoeger
769c64fe5e Replace ADD_ACTION macro by member function in profilewidget2.cpp
Signed-off-by: Berthold Stoeger <bstoeger@mail.tuwien.ac.at>
2018-01-10 21:25:02 +01:00
Berthold Stoeger
3d8b0e6d3f Replace HIDE_ALL macro by template function in profilewidget2.cpp
This is easier to read and debug.

Signed-off-by: Berthold Stoeger <bstoeger@mail.tuwien.ac.at>
2018-01-10 21:25:02 +01:00
Berthold Stoeger
6cf06fb61d Remove unnecessary deletes in destructor of ProfileWidget2
All the deleted items were added to the scene, which takes
"ownership" (a remarkably fuzzy concept in Qt) of these
objects. In principle, deleting these items is a bug - even
though it is handled gracefully.

Signed-off-by: Berthold Stoeger <bstoeger@mail.tuwien.ac.at>
2018-01-10 21:25:02 +01:00
Jan Mulder
1892e2af21 Unused code: remove ProfileWidget2::isAddOrPlanner()
Signed-off-by: Jan Mulder <jlmulder@xs4all.nl>
2018-01-10 16:45:42 +01:00
Jan Mulder
a88c950738 Unused code: DiveCartesianAxis::percentAt()
Signed-off-by: Jan Mulder <jlmulder@xs4all.nl>
2018-01-10 16:45:42 +01:00
Jan Mulder
d88e916c1d Unused code: remove DiveCartesianAxis::tickInterval() and tickSize()
Signed-off-by: Jan Mulder <jlmulder@xs4all.nl>
2018-01-10 16:45:42 +01:00
Jan Mulder
2fb5a7d082 cleanup: Uninitialized scalar field
CID 208332

Signed-off-by: Jan Mulder <jlmulder@xs4all.nl>
2017-12-29 09:14:20 -08:00
Jan Mulder
555f789b55 cleanup: Uninitialized pointer field
CID 45172

And one non initalized member hAxis could be removed as it is
not used. Surprisingly, Coverity did not see this.

Signed-off-by: Jan Mulder <jlmulder@xs4all.nl>
2017-12-29 09:14:20 -08:00
Berthold Stoeger
05a1626c7e Implement different zoom levels for dive photos tab
This implements different zoom levels for the dive photos tab as
suggested by Stefan Fuchs <sfuchs@gmx.de> in #898.
The zoom level can be changed using a slider or CTRL+mousewheel.
Zoom levels range from a third of the standard thumbnail size to
thrice the standard thumbnail size.

Thumbnails are cached in maximum resolution and scaled down on
the fly. Because the profile widget took its pictures from the
photo list model, an extra picture copy with a fixed size had
to be introduced.

The UI is still a bit crude.

Reported-by: Stefan Fuchs <sfuchs@gmx.de>
Signed-off-by: Berthold Stoeger <bstoeger@mail.tuwien.ac.at>
2017-12-18 12:07:10 -08:00
Stefan Fuchs
2890be9256 divepicturemodel: Reset start and end row for displayed_dive correctly
Correct way of using indices for rowDDstart and rowDDend.
Reset rowDDstart and rowDDend at beginning of updating dive pictures.

Signed-off-by: Stefan Fuchs <sfuchs@gmx.de>
2017-12-15 09:11:28 -08:00
Stefan Fuchs
7bc77947f6 Fine tune the position of pictures in the profile
Start a new column a little bit earlier otherwise it will get difficult
to fit a high number of pictures.
Don't put more than ~16 pictures in one column.

Signed-off-by: Stefan Fuchs <sfuchs@gmx.de>
2017-12-13 05:48:20 -08:00
Stefan Fuchs
5b7e4c57f7 Dive pictures show pictures of all selected dives
In the dive picture tab show pictures of all selected dive.
But at the same moment take care that in the profile only
pictures from displayed_dive are displayed.

Signed-off-by: Stefan Fuchs <sfuchs@gmx.de>
2017-12-13 05:48:20 -08:00
Robert C. Helling
4d605ce51f Prevent redundant replanning
Planning dives is heavy on CPU, so better be sure we only
do it when needed. In particular, when moving around dive
points, we only want a new plan once per move and not three
times (triggered at various points in the chain of events).

This should significantly improve planner snappiness.

Signed-off-by: Robert C. Helling <helling@atdotde.de>
2017-12-01 15:47:51 -08:00
Robert C. Helling
e06b507230 Control growth of time axis
While dragging waypoints around, don't grow the time axis according
to dive duration (including deco stops) as this can explode too
easly resulting in an effectively unresponsive planner. Rather
grow it only (slowly) when a dive handler is moved to the right
10% of the profile.

Signed-off-by: Robert C. Helling <helling@atdotde.de>
2017-12-01 15:47:51 -08:00
Stefan Fuchs
a1e6ac2e09 Dive picture handling: Re enable multi select, improve mouse events
Some improvements for the dive picture tab and dive pictures in profile:
- Bugfix mouse event in profile: Only Left-click will open picture
- Bugfix mouse events in picture tab:
  - Re-enable context menu (Windows bug mainly)
  - Re-enable multi select in a nice way
  - Only double-left-click will open picture

Signed-off-by: Stefan Fuchs <sfuchs@gmx.de>
2017-12-01 09:44:34 +01:00
Martin Měřinský
8ef87e618a Use better aliases for icons.
Icon aliases were complete mess.
Some icons had alias some didn't.
Named with underscores vs. hyphens vs. camelCase.
Lower vs. upper case.
"ICON" prefix vs. suffix vs. nothing.
With vs. without filename suffix.
Some didn't make sence. Eg. mapwidget-marker-gray
(I can see, it's grey, but what does it represent?)
Some were duplicated, eg warning vs. warning-icon.
Some were name after widget, which is wrong.

Do not reinvent wheel. Use widely used naming scheme
close to Freedesktop Icon Naming Specification. This
will enable usage of common icons from current set in
the future. Thus Subsurface will fit nicely to GUI.

This changes icon aliases to one, easy grep-able style.

Signed-off-by: Martin Měřinský <mermar@centrum.cz>
2017-11-30 23:14:46 -08:00
Dirk Hohndel
2747056889 Revert "Use consistent aliases for all icons."
This reverts commit 92e9c6606f.
2017-11-29 14:05:07 -08:00
Martin Měřinský
92e9c6606f Use consistent aliases for all icons.
Icon aliases were inconsistent mess. Underscores vs. hyphens vs. camelCase.
With vs. without filename suffix. Lower vs. upper case. "icon" suffix vs.
prefix vs. nothing. Some were duplicated, eg warning vs. warning-icon. Some
icons didn't have alias at all.

This changes all icon aliases to one, easy grep-able style which complies
to Freedesktop Icon Naming Specification (Guidelines).

Signed-off-by: Martin Měřinský <mermar@centrum.cz>
2017-11-29 11:46:35 +01:00
Berthold Stoeger
82898a837d Fix toggling of partial pressure graphs
When toggling the display of the partial pressure graph, the graph was
either not shown correctly or unnecessary ticks were left in the graph.
Calling the settingsChanged() method of the profileYAxis object solves
the problem by initializing the ticks according to the selected graphs.

Signed-off-by: Berthold Stoeger <bstoeger@mail.tuwien.ac.at>
2017-11-25 15:42:44 -08:00
Stefan Fuchs
5da6362679 In strings change tank to cylinder
Change the word "tank" to "cylinder" or "cyl." in two occurences.

Signed-off-by: Stefan Fuchs <sfuchs@gmx.de>
2017-11-25 15:41:28 -08:00
Robert C. Helling
088db5e12b Hand planner variables to profile
Pass the planner state struct to the profile computation so it can use
deco_time and first ceiling to display VPM-B ceiling.

Signed-off-by: Robert C. Helling <helling@atdotde.de>
2017-11-25 20:13:01 +01:00
Berthold Stoeger
178dcbc0c6 Fix obscure display bug in profile widget, where heat map wasn't shown
Fixes an obscure bug, which happened under very specific circumstances.
Precodition: fresh program start and neither of the partial pressure
graphs, nor the heat maps are shown. User clicks on heat map icon.
Bug: The heat map is not shown at the bottom of the graph.

The fix consists in replacing two percentageAxis->setLine() calls
by precentageAxis->animateChangeLine() calls.

Signed-off-by: Berthold Stoeger <bstoeger@mail.tuwien.ac.at>
2017-11-23 14:15:00 -08:00
Berthold Stoeger
f8fcd65bc4 Prevent signed/unsigned comparison warning
Change an unsigned integer to a signed integer in profilewidget2.cpp,
because commit 1f8506c changed the definition of duration_t from
unsigned to signed.

Since this value represents the number of seconds since a dive started,
there is no possible chance of overflow problems.

Signed-off-by: Berthold Stoeger <bstoeger@mail.tuwien.ac.at>
2017-11-18 21:50:43 +01:00
Jan Mulder
0d023068b3 mobile: icon size in profile
Size the event item icons in the profile a little bigger. Obviously, how
big is big enhough is upto personal taste, but on Github a screendump
is added to show the new size.

Fixes: #310

Signed-off-by: Jan Mulder <jlmulder@xs4all.nl>
2017-11-13 20:46:00 -08:00
Dirk Hohndel
e64dcd12bd desktop UI: no longer attempt to manually show error notifications
report_error() now does this automatically. So all these odd places in which we tried
to make sure that we show errors are no longer needed.

Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
2017-10-26 15:55:49 +02:00
Dirk Hohndel
27c49fe3ad Silence random warnings
None of these seem to point to actual issues, so let's quiet them.

Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
2017-10-20 17:25:18 -04:00
Stefan Fuchs
022b3e450b Translate dc text in profile also if string has suffix for > 1 DC
Signed-off-by: Stefan Fuchs <sfuchs@gmx.de>
2017-10-20 06:38:20 -04:00
Stefan Fuchs
c3274b0b9f When selecting icons for events don't misinterpret a gaschange
Don't misinterpret a gaschange as "useless internal of the dive computer"
when it has a higher flag value.

Signed-off-by: Stefan Fuchs <sfuchs@gmx.de>
2017-10-19 19:00:55 -04:00
Robert C. Helling
a422957cd6 Use displayed_dc instead of current_dc
current_dc is a macro that determines the dive computer
based on the current dive number. When the planner is started
from an emtpy dive list, the dive number ends up being -1 and
that doesn't produce a valid dive computer. Use the divecomputer
of the displayed_dive instead. This is done via a macro that
can also be used in two other places. Without this patch, the
planner crashed when called on an empty dive list.

Signed-off-by: Robert C. Helling <helling@atdotde.de>
2017-10-19 14:57:02 -04:00
Stefan Fuchs
fcc4be6ea0 Add a icon for gaschange to Oxy with all green tank shoulder color
Signed-off-by: Stefan Fuchs <sfuchs@gmx.de>
2017-10-18 06:47:44 -04:00
Robert C. Helling
432110ac8f Find current gasmix for heatmap
To compute the heatmap value, we need the current gasmix but
the current cylinderindex is no longer available.

Fixes #562

Suggested-by: Linus Torvalds <torvalds@linux-foundation.org>
Signed-off-by: Robert C. Helling <helling@atdotde.de>
2017-10-18 06:34:15 -04:00
Stefan Fuchs
c3857db23b Hide outdated gas name strings in profile in planner
When deleting dive planner points in the planner we currently sometimes
miss to hide the outdated gas name strings printed close to the profile
legs.

Signed-off-by: Stefan Fuchs <sfuchs@gmx.de>
2017-10-08 23:19:23 +02:00
Stefan Fuchs
8d8e694b0d End tankbar at the correct end of the dive plot
Go back to the old startegy of retrieving the correct end of the dive
plot by looking at the plot data instead of looking at dc->duration.

Signed-off-by: Stefan Fuchs <sfuchs@gmx.de>
2017-09-15 09:01:10 -07:00
Dirk Hohndel
96ed09bf14 Update the tankbar code to work with the new gas handling
When Linus modified the gas handling code six weeks ago he pointed out
that that had broken the tankbar; with this patch we now simply walk the
gas changes of the displayed dive directly and create the tankbar
rectangles from that information.

See #562

Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
2017-09-14 05:36:52 +02:00
Dirk Hohndel
aabcff9c54 Move unused code into the disabled block
These varaiables are only used in the code that we currently
aren't compiling.

Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
2017-08-26 12:11:44 -07:00
Linus Torvalds
e04ef1df1e Fix the overprinting of gas name and pressure value on the profile
When I massaged the code to do multiple gas pressures in commit e1b880f4
("Profile support for multiple concurrent pressure sensors") some of the
Y offsetting code got cut out as being too specific to the old
o2pressure code.

But I removed a bit too much, leaving the label (gas name) and number
(gas pressure) overlapping.

This should fix it.

If we really care about multiple gas pressure labels overlapping each
other, we'll have to revisit this code, but the old two-gas case didn't
do a very good job either (both that old code - and this new version -
can look very good in particular cases, but there are cases where it
won't work so well).

So we may need to revisit this eventually, but this gets it looking fine
for the normal cases.

Reported-by: Miika Turkia <miika.turkia@gmail.com>
Signed-off-by: Linus Torvalds <torvalds@linux-foundation.org>
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
2017-08-07 00:57:58 -07:00
Linus Torvalds
e1b880f444 Profile support for multiple concurrent pressure sensors
This finally handles multiple cylinder pressures, both overlapping and
consecutive, and it seems to work on the nasty cases I've thrown at it.

Want to just track five different cylinders all at once, without any
pesky gas switch events? Sure, you can do that.  It will show five
different gas pressures for your five cylinders, and they will go down
as you breathe down the cylinders.

I obviously don't have any real data for that case, but I do have a test
file with five actual cylinders that all have samples over the whole
course of the dive.  The end result looks messy as hell, but what did
you expect?

HOWEVER.

The only way to do this sanely was

 - actually make the "struct plot_info" have all the cylinder pressures
   (so no "sensor index and pressure" - every cylinder has a pressure for
   every plot info entry)

   This obviously makes the plot_info much bigger. We used to have
   MAX_CYLINDERS be a fairly generous 8, which seems sane. The planning
   code made that 8 be 20. That seems questionable. But whatever.

   The good news is that the plot-info should hopefully get freed, and
   only be allocated one dive at a time, so the fact that it is big and
   nasty shouldn't be a scaling issue, though.

 - the "populate_pressure_information()" function had to be rewritten
   quite a bit. The good news is that it's actually simpler now, although
   I would not go so far as to really call it simple. It's still
   complicated and suble, but now it explicitly just does one cylinder at
   a time.

   It *used* to have this insanely complicated "keep track of the pressure
   ranges for every cylinder at once". I just couldn't stand that model
   and keep my sanity, so it now just tracks one cylinder at a time, and
   doesn't have an array of live data, instead the caller will just call
   it for each cylinder.

 - get rid of some of our hackier stuff, like the code that populates the
   plot_info data code with the currently selected cylinder number, and
   clears out any other pressures. That obviously does *not* work when you
   may not have a single primary cylinder any more.

Now, the above sounds like all good things. Yeah, it mostly is.

BUT.

There's a few big downsides from the above:

 - there's no sane way to do this as a series of small changes.

   The change to make the plot_info take an array of cylinder pressures
   rather than the sensor+pressure model really isn't amenable to "fix up
   one use at a time". When you switch over to the new data structure
   model, you have to switch over to the new way of populating the
   pressure ranges. The two just go hand in hand.

 - Some of our code *depended* on the "sensor+pressure" model. I fixed all
   the ones I could sanely fix. There was one particular case that I just
   couldn't sanely fix, and I didn't care enough about it to do something
   insane.

   So the only _known_ breakage is the "TankItem" profile widget. That's
   the bar at the bottom of the profile that shows which cylinder is in
   use right now. You'd think that would be trivial to fix up, and yes it
   would be - I could just use the regular model of

     firstcyl = explicit_first_cylinder(dive, dc)
     .. then iterate over the gas change events to see the others ..

   but the problem with the "TankItem" widget is that it does its own
   model, and it has thrown away the dive and the dive computer
   information. It just doesn't even know. It only knows what cylinders
   there are, and the plot_info. And it just used to look at the sensor
   number in the plot_info, and be done with that. That number no longer
   exists.

 - I have tested it, and I think the code is better, but hey, it's a
   fairly large patch to some of the more complex code in our code base.
   That "interpolate missing pressure fields" code really isn't pretty. It
   may be prettier, but..

Anyway, without further ado, here's the patch. No sign-off yet, because I
do think people should look and comment. But I think the patch is fine,
and I'll fix anythign that anybody can find, *except* for that TankItem
thing that I will refuse to touch. That class is ugly. It needs to have
access to the actual dive.

Note how it actually does remove more lines than it adds, and that's
despite added comments etc. The code really is simpler, but there may be
cases in there that need more work.

Known missing pieces that don't currently take advantage of concurrent
cylinder pressure data:

 - the momentary SAC rate coloring for dives will need more work

 - dive merging (but we expect to generally normally not merge dive
   computers, which is the main source of sensor data)

 - actually taking advantage of different sensor data from different
   dive computers

But most of all: Testing.  Lots and lots of testing to find all the
corner cases.

Signed-off-by: Linus Torvalds <torvalds@linux-foundation.org>
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
2017-07-27 14:45:58 -07:00
Linus Torvalds
342391e0d1 Show multiple gas pressures in the profile even if the dive isn't CCR
Now that the cylinder pressures are more generalized, we should show
them even for non-CCR dives if we have them.  The most notable example
would be having separate pressure transmitters for both cylinders in a
sidemount setup. The code no longer really depends on any CCR logic.

NOTE! This is still preparatory work, in that this is one part of
supporting multiple simulataneous cylinder pressures, but we are still
lacking in other departments (eg properly filling those fields in when a
dive computer exports multiple pressure sensors etc).

Signed-off-by: Linus Torvalds <torvalds@linux-foundation.org>
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
2017-07-22 10:38:32 -07:00
Linus Torvalds
1e38d9239a Start cleaning up sensor indexing for multiple sensors
This is a very timid start at making us actually use multiple sensors
without the magical special case for just CCR oxygen tracking.

It mainly does:

 - turn the "sample->sensor" index into an array of two indexes, to
   match the pressures themselves.

 - get rid of dive->{oxygen_cylinder_index,diluent_cylinder_index},
   since a CCR dive should now simply set the sample->sensor[] indices
   correctly instead.

 - in a couple of places, start actually looping over the sensors rather
   than special-case the O2 case (although often the small "loops" are
   just unrolled, since it's just two cases.

but in many cases we still end up only covering the zero sensor case,
because the CCR O2 sensor code coverage was fairly limited.

It's entirely possible (even likely) that this migth break some existing
case: it tries to be a fairly direct ("stupid") translation of the old
code, but unlike the preparatory patch this does actually does change
some semantics.

For example, right now the git loader code assumes that if the git save
data contains a o2pressure entry, it just hardcodes the O2 sensor index
to 1.

In fact, one issue is going to simply be that our file formats do not
have that multiple sensor format, but instead had very clearly encoded
things as being the CCR O2 pressure sensor.

But this is hopefully close to usable, and I will need feedback (and
maybe test cases) from people who have existing CCR dives with pressure
data.

Signed-off-by: Linus Torvalds <torvalds@linux-foundation.org>
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
2017-07-21 16:33:19 -07:00
Stefan Fuchs
b8347d2387 Translate the strings "planned dive" and "manually added dive" in the profile
Signed-off-by: Stefan Fuchs <sfuchs@gmx.de>
2017-06-22 10:38:54 +09:00
Jan Mulder
26a0e741b8 code cleanup: remove unimplemented classes and structs
Remove forward declared but not implemented classes and structs.

Signed-off-by: Jan Mulder <jlmulder@xs4all.nl>
2017-06-16 05:31:41 +09:00
Robert C. Helling
98a65b7157 Display gas density instead of SAC in planner
In the planner, the SAC is prescribed, so there is little
use in plotting it (as the color of the cylinder pressure
line). Rather use the color to show the density of breathing
gas.

Signed-off-by: Robert C. Helling <helling@atdotde.de>
2017-05-26 15:52:04 -07:00
Robert C. Helling
53a8075bd8 Fix right boundary when moving last handle in planner
There was a bug in the old code due to confusion between minutes
and seconds as the unit of the time axis. But rather than limiting
the time for the last handle in terms of the time axis (which
potentially includes long deco and allowing that for bottom time
quickly leads to dives many many hours long) limit it to 150%
of the previous bottom time.

Signed-off-by: Robert C. Helling <helling@atdotde.de>
2017-05-26 15:46:41 -07:00
Dirk Hohndel
49d0bb8406 Add SPDX header to profile widgets
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
2017-04-29 13:32:55 -07:00
Jan Mulder
5a235aea12 minimal pO2 threshold: color the p02 graph also for minumum
Color the p02 graph also in red for going under the minumum p02 value as
set in the Preferences.

Signed-off-by: Jan Mulder <jlmulder@xs4all.nl>
2017-03-28 11:17:03 -07:00
Jan Mulder
bb31c77597 minimal pO2 threshold: split max threshold into min and max
Nothing really special here. Just a split of the only p02 max threshold into
a min threshold and max threshold, and the adaptation of the UI. Change of
translatable strings included.

ref: https://github.com/Subsurface-divelog/subsurface/issues/259

Signed-off-by: Jan Mulder <jlmulder@xs4all.nl>
2017-03-28 11:17:03 -07:00
Joakim Bygdell
bd0c99dfb7 MOBILE: Display pO2 and Setpoint for CCR dives
For CCR dives we want to display the setpoint and pO2 information,
due to the limited screensize we have to remove the temperature graph or
the view will be to cluttered.

Signed-off-by: Joakim Bygdell <j.bygdell@gmail.com>
2017-03-26 21:57:57 -07:00
Jeremie Guichard
597539ce39 Fix double to int truncation in C++ code
Wfloat-conversion enabled for C++ part of the code
Fix warnings raised by the flag using lrint

Original issue reported on the mailing list:
The ascent/descent rates are sometimes not what is expected.
E.g. setting the ascent rate to 10m/min results in an actual
ascent rate of 9m/min.
This is due to truncating the ascent rate preference,
then effectively rounding up the time to reach each stop to 2s intervals.
The result being that setting the ascent rate to 10m/min
results in 20s to ascend 3m (9m/min), when it should be exactly 18s.

Reported-by: John Smith <noseygit@hotmail.com>
Reported-by: Rick Walsh <rickmwalsh@gmail.com>
Signed-off-by: Jeremie Guichard <djebrest@gmail.com>
2017-03-24 09:39:25 -07:00
Dirk Hohndel
08284275e7 Merge branch 'master' of https://github.com/dje29/subsurface 2017-03-11 08:41:41 -08:00
Martin Měřinský
95d5771513 We use 'setpoint' in UI. Use it also for documentation and comments. No semantic change. 2017-03-11 08:09:07 -08:00
Martin Měřinský
dcf2542215 Use abbreviations with dots. 2017-03-11 08:09:07 -08:00
Robert C. Helling
eae4bd82a5 Change type of divedatepoint.depth to depth_t
... for consistency, while we are at it.

There are still some internal depth variables which are ints
somebody might take a go at those.

Signed-off-by: Robert C. Helling <helling@atdotde.de>
2017-03-11 08:03:25 -08:00
Jeremie Guichard
406e4287eb Change calls to rint into lrint avoiding conversion warnings
Using gcc option "-Wfloat-conversion" is useful to catch
potential conversion errors (where lrint should be used).
rint returns double and still raises the same warning,
this is why this change updates all rint calls to lrint.
In few places, where input type is a float, corresponding
lrinf is used.

Signed-off-by: Jeremie Guichard <djebrest@gmail.com>
2017-03-08 14:04:17 +07:00
Martin Měřinský
b14301a84c heartrate, heartbeat > heart rate 2017-03-04 12:08:17 -08:00
Martin Měřinský
59d18a00db divecomputer > dive computer 2017-03-04 12:08:17 -08:00
Stefan Fuchs
7eda24d6b1 Correct "set-point" -> "setpoint" and window title setpoint change
Change 2x "set-point" to "setpoint".
Correct window title for "Add setpoint change" window.

Signed-off-by: Stefan Fuchs <sfuchs@gmx.de>
2017-03-04 12:04:20 -08:00
Stefan Fuchs
508387b1e1 Add units and nicer formating for items in profile info box
"SP change" info format in info box: Added/changed formating and add "bar" unit.
"waypoint above ceiling" event in info box: Added formating, depth conversation to ft/m and depth unit.

Signed-off-by: Stefan Fuchs <sfuchs@gmx.de>
2017-02-21 13:11:19 -08:00
Stefan Fuchs
b39b641a05 Translate names of additional dive events and nicer format info box text
Enable translation for a few additional internal dive events.
Ensure that all event names in datatrak.c are collected for translation.
Ensure that for gaschange in profile info box the "cyl." string is also translated.

Signed-off-by: Stefan Fuchs <sfuchs@gmx.de>
2017-02-21 13:11:19 -08:00
Joakim Bygdell
12c33a038f Mobile: Do not show tankbar for CCR dives
If we are showing the setpoint and sensor pO2 we need the space.

Signed-off-by: Joakim Bygdell <j.bygdell@gmail.com>
2017-02-05 12:20:33 -08:00
Joakim Bygdell
11ccadbab5 MOBILE: Reposition objects in the profile
Add the tankbar to the profile and change the relative positions of the depth
and temperature curves to minimize overlap.

Signed-off-by: Joakim Bygdell <j.bygdell@gmail.com>
2017-02-05 11:59:47 -08:00
Robert C. Helling
2516ae7e5f Let cylinderid = -1 mean same gas as before
It's not too clever to give 0 a special meaning (as here:
use same gas as for previous leg) when 0 is a legitimate
value.

This should solve Willem's gas disappearance problem when
reediting a dive in the planner.

Signed-off-by: Robert C. Helling <helling@atdotde.de>
2017-02-04 07:09:35 -08:00
Dirk Hohndel
f5a4838519 Fix dive visual editor being too quick to rescale time
When moving the last handle of a dive (in the planner, in dive add, or
when editing a dive), we rescaled the time axis whenever our idea of the
maximum duration that we should show changed. That lead to the odd
situation that you couldn't get to certain dive durations with the
visual editor (e.g. 64 minutes) because just as you approach that time
the scale changes and the dive duration jumps past the desired value.

Fixes issue #174

Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
2017-01-28 21:04:50 -08:00
Joakim Bygdell
dd2791fa1e Fix tankbar offset at gas switch event
When painting the tankbar the function triggers on change in cylinder index,
as a result the new gascolour are changed at the next sample time point.
On a divecomputer with a reasonable fast sample rate the 2-3s offset are hardly
noticable, especially on a longer dive.
For divecomputers with slow sample rate the 10-30s offset are clearly visible.

This is fixed by start painting the new gascolour at the time point of the switch event rather than the time point of the next sample.

Signed-off-by: Joakim Bygdell <j.bygdell@gmail.com>
2017-01-21 06:07:31 -08:00