First step to being able to filter the events that we display in the
profile. We could (in theory) walk all the dives in the divelist when we
need this data, but it seems much more convenient to have them in an array
in one place.
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
This way you can just type the first few characters of a location you've
been to before, and it will show you a list of possible completions.
Same for buddies and divemasters (which take the completions from a list
of people you've used before).
Signed-off-by: Linus Torvalds <torvalds@linux-foundation.org>
This way the cylinder model list will contain all the different
cylinders that we have ever seen, rather than only containing the models
that we have *edited*.
That makes it much more practical to add new dives with the same
cylinders that we've used before, because now those cylinders will show
up as cylinder models even if we haven't looked and edited the old dives
first.
Signed-off-by: Linus Torvalds <torvalds@linux-foundation.org>
Open (or adding a file name on the command line) means that this is just
one of the files that you consider part of your dive history. So dives
don't get automagically numbered and the dive_list is not considered
"changed" just because another file was opened.
Import (or adding a file on the command line after --import) means that
you are importing the content of this file to your dive history. So if the
imported file has un-numbered dives that are newer than everything else,
those get correctly renumbered. And importing marks the dive_list as
changed.
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
When importing (or reading xml from files) new dives, we now renumber
them based on preexisting dive data, *if* such re-numbering is obvious.
NOTE! In order to be "obvious", there can be no overlap between old and
new dives: all the new dives have to come at the end. That's what
happens with a normal libdivecomputer import, since we cut the import
short when we find a preexisting dive.
But if any of the new dives overlap the old dives in any way, or already
have been numbered separately, the automatic renumbering is not done,
and you need to do a manual renumber.
Signed-off-by: Linus Torvalds <torvalds@linux-foundation.org>
We can instead 'Open' these files as they are just bastardized XML files.
This gets us back to a more consistent point where 'Import' gets data
directly from the dive computer (and hopefully soon we will add the
ability to load a dive directly from a uemis SDA to libdivecomputer),
and 'Open' loads a file from the filesystem of the computer we are
running on (this last sentence phrased so awkwardly as the uemis Zurich
SDA is a computer and presents a file system when connected via USB - it
just doesn't have the dive data in an accessible format in that file
system).
As a bonus we get to throw away quite a bit of code (the uemis specific
file handling, mini-XML parser with helper functions, the file open dialog
in the importer). Yay!
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
* 'otu-tracking-v2' of git://github.com/dirkhh/subsurface:
Make OTU column invisible by default
Add OTU to divelist
Calculate OTUs for every dive
Fix up trivial conflicts in dive.h (due to dive event handling also
adding a field to the dive structure)
Parse them, save them, take them from libdivecomputer.
This doesn't merge them or show them in the profile yet, though.
Signed-off-by: Linus Torvalds <torvalds@linux-foundation.org>
The calculation assumes that the cylinderindex in each sample tells us
which PO2 the dive was breathing at that time. This needs to be verified
with dives where there is an actual gas switch.
No idea where to display them, yet. Far fewer people will care about this
than care about SAC - does this still rate a spot in the dive_list?
I guess I could make it part of the dive_info - but it's not editable.
It doesn't seem to fit with the equipment page (even though this is the
one editable field that is related - nitrox %)
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
* 'quit-handling' of git://github.com/dirkhh/subsurface:
Use the last (or only) filename on command line as default for saving
Show the "save changes" dialog before the main window is destroyed
Check for changes at regular 'quit' events as well
Catch changes to the info of the current dive when quitting
Tracking changes to tanks is trivial
Simplistic first attempt to get changes saved when quitting subsurface
Use the actual degree sign for temperatures (°F and °C), and make sure
everything uses the proper "set_source_rgb[a]()" wrappers to set the
colors.
Signed-off-by: Linus Torvalds <torvalds@linux-foundation.org>
The following are UI toolkit specific:
gtk-gui.c - overall layout, main window of the UI
divelist.c - list of dives subsurface maintains
equipment.c - equipment / tank information for each dive
info.c - detailed dive info
print.c - printing
The rest is independent of the UI:
main.c i - program frame
dive.c i - creates and maintaines the internal dive list structure
libdivecomputer.c
uemis.c
parse-xml.c
save-xml.c - interface with dive computers and the XML files
profile.c - creates the data for the profile and draws it using cairo
This commit should contain NO functional changes, just moving code around
and a couple of minor abstractions.
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
It got removed by some of my overly aggressive cleanup in commit
fefcbf125e ("Remove dive info frame") because the dive info frame
initialization also initialized the main window title..
Signed-off-by: Linus Torvalds <torvalds@linux-foundation.org>
Even though we go down to an 8pt font the info_frame changes size when the
air info is added. I don't like this but want to see how Linus would like
this resolved before going overboard.
Minor tweaks to the formating (we don't need two decimals when printing
the liters of air consumed).
This patch does NOT remove the plot of the air information in the profile
graph. I think we want to remove that once we like the text where it is,
but I wanted to do one thing at a time.
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
Sadly, no way to show them yet. But it would be nice to let people
enter them (and it would be doubly nice to have a dive computer that
does it at the surface), and then perhaps just do the "point browser at
google maps" thing.
Saving/parsing tested by hand-feeding the location of Enenui (Molokini
Crater) from google maps by hand into my divelog.
Signed-off-by: Linus Torvalds <torvalds@linux-foundation.org>
I have it in some of my notes, and Dirk seems to fill that in too, so
let's just show it, save it, and allow editing of it..
Signed-off-by: Linus Torvalds <torvalds@linux-foundation.org>
So this actually reports the dive data that libdivecomputer generates.
It doesn't import special events etc, but neither do we for the xml
importer.
It is also slow as heck, since it doesn't try to do the "hey, I already
have this dive" logic and always imports everything, but the basics are
definitely there.
Signed-off-by: Linus Torvalds <torvalds@linux-foundation.org>
We're going to start to want to allocate dives and samples for the
libdivecomputer import too, so let's clean things up a bit for that.
Signed-off-by: Linus Torvalds <torvalds@linux-foundation.org>
libdivecomputer already uses 'gasmix_t' for its own gasmix thing. I
don't like th eway we step on each others name spaces, but hey, might as
well just use 'struct gasmix' and avoid the typedef.
Signed-off-by: Linus Torvalds <torvalds@linux-foundation.org>
When we change units, we need to flush any currently active dive
information in the old units, and then carefully reload it in the new
units.
Otherwise crazy stuff happens - like having current cylinder working
pressure values that are in PSI because that *used* to be the output
unit, but then interpreting those values as BAR, because we changed the
units.
Also, since we now properly import working pressure from Diving Log,
stop importing the (useless) cylinder description. The Diving Log
cylinder descriptions are things like "Alu" or "Steel". We're better
off just making up our own.
Finally, since Diving Log has cylinder size in metric, make sure that we
do the "match standard cylinder sizes" *after* we've done all the
cylinder size conversions to proper units.
Signed-off-by: Linus Torvalds <torvalds@linux-foundation.org>
Some people want to know how many dives they have under their belt, so
let's save and restore the dive number if it exists.
Signed-off-by: Linus Torvalds <torvalds@linux-foundation.org>
Make it about general equipment management, and start hooking up
functions to show new equipment information when changing dives (and to
flush changes to equipment information for the previously active dive).
Nothing is hooked up yet, and it's now showing just one (really big)
cylinder choice, so this is all broken. But it should make it possible
to at least get somewhere some day.
Signed-off-by: Linus Torvalds <torvalds@linux-foundation.org>
This should take care of it all, unless I missed some case.
Now we should just save the default units somewhere, and I should do the
divelist update much cleaner (instead of re-doing the divelist entirely,
it should just repaint it - now we lose the highlited dive etc).
Signed-off-by: Linus Torvalds <torvalds@linux-foundation.org>
This doesn't actually *do* anything yet, but it introduces the notion of
output units, and allows you to pick metric or imperial.
Of course, since the output doesn't currently care, the units you pick
are irrelevant. But just wait..
Signed-off-by: Linus Torvalds <torvalds@linux-foundation.org>
Doing per-dive cylinder start/end pressures is insane, when we can have
up to eight cylinders. The cylinder start/end pressure cannot be per
dive, it needs to be per cylinder.
This makes the save format cleaner too, we have all the cylinder data in
just one place.
Signed-off-by: Linus Torvalds <torvalds@linux-foundation.org>
This is some seriously crazy stuff. Instead of making sense as a
divelog, the uemis xml makes more sense as a "dive computer settings
dump".
And I guess I can see why they'd do that. But it makes parsing it just
incredibly annoying. The thing is more of a "these are the
configurations I support as a dive computer thing" than a "this was the
tank you were diving with".
Signed-off-by: Linus Torvalds <torvalds@linux-foundation.org>
.. and sort based on the 'time_t' value itself.
This allows us to use a more compact date format that doesn't need to
sort alphabetically, because sorting by date is always based on the date
value. So we can use just a two-digit year, and skip the seconds, to
keep the column narrow, while still sorting correctly.
Also, "Depth" is a nice header string, but it is wider than the column
itself, which makes the whole column wider than necessary. So put the
units in the header instead of in the string, keeping things narrow.
Signed-off-by: Linus Torvalds <torvalds@linux-foundation.org>
So we don't want to save working pressure, but cylinder type knowledge
would be lovely and useful. And we can probably make a good initial
guess, or at least let people fill it in later.
Signed-off-by: Linus Torvalds <torvalds@linux-foundation.org>
Instead of just tracking gasmix, track the size and workng pressure of
the cylinder too.
And use "cylinder" instead of "tank" throughout.
Signed-off-by: Linus Torvalds <torvalds@linux-foundation.org>
Now the dive profile plot *really* needs some units. The pressure is
just a random line otherwise.
Signed-off-by: Linus Torvalds <torvalds@linux-foundation.org>
If given multiple dives at the same time, just de-dup the dives. This
happens when you've dumped the whole dive-computer several times, and
some dives show up in multiple dumps.
When de-duping, try to avoid dropping data. So if one dive has notes
attached to it, and the other one does not, pick the notes from the dive
that does have them. Obvious stuff like that.
The sample merge is also written so that it should be possible to merge
two dives. Which we don't actually do yet.
Signed-off-by: Linus Torvalds <torvalds@linux-foundation.org>
This just generates another xml file. Don't get me wrong: I still don't
like xml, but this way we can save in the same format we load things
from. Except the save-format is a *lot* cleaner than the abortion that
is Suunto or libdivecomputer xml.
Don't bother with some crazy xml library crap for saving. Just do it!
Signed-off-by: Linus Torvalds <torvalds@linux-foundation.org>
The only thing you can do with that thing is screw things up (like
libdivecomputer did). There's no value in tracking the "filler" gas,
since you can always just calculate it from the gases that actually
matter.
So just track Oxygen and Helium - and make sure they have sane values.
Signed-off-by: Linus Torvalds <torvalds@linux-foundation.org>
The suunto xml is just completely crazy. What's the helium percentage
companion to "o2pct"? Would it be "hepct"? No. It's "hepct_0".
Ok, so they didn't number the first o2pct, which could be seen as sane:
that's the only mix value that should always exist. And they clearly
started their indexing with 0. So with multiple mixes, you'd then
expect "o2pct_1" and "hepct_1", right?
Wrong! Because XML people are crazy, the second O2 mix percentage is
obviously "o2pct_2". So the O2 percentages are one-based, with an
implicit one. But the He percentages are zero-based with an explicit
zero. So the second mix is "o2pct_2" and "hepct_1".
I'd like to ask what drugs Suunto people are on, but hey, it's a Finnish
company. No need to ask. Vodka explains everything. LOTS AND LOTS OF
VODKA.
In comparison, the libdivecomputer output is nice and sane, and uses a
'gasmix' node. Of course, now we have so many different XML nesting
nodes to check that I just made it an array of different noces. That
also allows me to mark the suunto case, so that we only do the "check
for crazy alcoholic xml entries" when it's a suunto file.
The "type of file" thing is probably a good idea for deciding on default
units too. Some day.
Signed-off-by: Linus Torvalds <torvalds@linux-foundation.org>
I'm going to add a menu to import (and eventually export) dives, and so
we'd like to be able to start out with no dives at all. Right now we
croak if that happens - it's not like the code has been written with
actual end users in mind.
So start cleaning things up. First make the 'current_dive' macro work
right even for invalid dives.
Signed-off-by: Linus Torvalds <torvalds@linux-foundation.org>
The name is a string containint date, time, depth and length. So it's
useful even with nothing else going on.
Signed-off-by: Linus Torvalds <torvalds@linux-foundation.org>
The dive parser should eventually be just a part of the program, not the
whole thing. So start preparing for that.
Signed-off-by: Linus Torvalds <torvalds@linux-foundation.org>