Showing an Error message is better called from the Notification Object,
So for consistency old references to showError is replaced by calling
the notification object.
Signed-off-by: Gehad elrobey <gehadelrobey@gmail.com>
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
This is the last patch in the series of clearing up the
mainwindo.ui. Now to bugfixing.
Signed-off-by: Tomaz Canabrava <tomaz.canabrava@intel.com>
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
Now it's created in the mainwindow.cpp as part of the new
way to configure the interface.
Signed-off-by: Tomaz Canabrava <tomaz.canabrava@intel.com>
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
It's now set up from the mainwindow.cpp file.
Signed-off-by: Tomaz Canabrava <tomaz.canabrava@intel.com>
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
Instead of inventing another way to do this (and inevitably forgetting a
path where this should be re-enabled) I renamed the DcShortcup related
function and made them enable/disable the copy and paste shortcuts as
well.
Of course there now is one exception (isn't there always?): in "ADD" state
we don't want to be able to switch DCs, but we do want to be able to
paste.
Fixes#825
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
Without this patch, the user effectively cannot change the dive mode as
any change is overwritten by replot copying current_dive over
displayed_dive. The way out is not to call replot but only update the deco
ceiling directly.
Signed-off-by: Robert C. Helling <helling@atdotde.de>
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
This ruler shouldn't appear in ADD or PLAN mode, it's a bug
and may crash things.
Signed-off-by: Tomaz Canabrava <tomaz.canabrava@intel.com>
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
When calculating maxima for a dive, we need to take data from all existing
dive computer structures plus potentially also a fake dive computer
structure that is just passed in in order to create a meaningful profile.
Commit 86c961614b ("Actually walk all dive computers, don't just claim
to do so") missed that second case and no longer took the fake_dc into
account, breaking the display of dives that don't have samples.
Reported-by: Miika Turkia <miika.turkia@gmail.com>
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
There were situations when the last text was still shown. E.g. when the
current file was closed and then a new dive was imported from CSV.
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
This patch does some cleaning up of the code that provides visualisation
of CCR o2 sensor and o2 setpoint data. It reduces the number of
conditional evalauations that are required and it improves the readability
of these parts of the code.
Signed-off-by: willem ferguson <willemferguson@zoology.up.ac.za>
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
This patch creates the possibility of viewing the individual sensor
values when the po2 button on the profile toolbar is activated. This
follows exactly the procedure for optionally displaying the setpoint
values while viewing po2. A checkbox in the preferences panel determines
whether sensor information is shown. By default it is set to OFF. When
checked, and the po2 button is activated, sensor1 values are shown in
grey, sensor2 in blue and sensor3 in brown.
Signed-off-by: willem ferguson <willemferguson@zoology.up.ac.za>
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
If the first dive computer had pressure samples, but the second one (and
no higher one) did, then we would draw a flat horizontal line for the tank
pressure graph (but lable it with the correct pressures). This routine
that is hunting for the actual maxima and minima does have to really go
through all dive computers, not just "this one and up".
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
qt-ui/profile/profilewidget2.cpp:1351:10: error: invalid use of incomplete type ‘class QDebug’
qt-ui/printlayout.cpp:141:27: error: variable ‘QPointer<ProfileWidget2> profile’ has initializer but incomplete type
In commit f9ceff009b ("Clean up the header files") things got broken for
an as of now unreliesed future version of Qt.
Signed-off-by: Thiago Macieira <thiago@macieira.org>
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
Move the heart rate graph down to the same space as the tissue saturation
graph so that it does not overlap with temperature or partial pressures.
Signed-off-by: Joakim Bygdell <j.bygdell@gmail.com>
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
Lots and lots and lots of header files were being included without being
needed. This attempts to clean some of that crud up.
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
We did three cals to mapToScene / mapFromScene on the mouse moveEvent at
the ProfileWidget2 where we only needed to call one in the common case and
two in the worst case.
This doesn't really help in terms of speed (unless you have a really old
cpu) but since it's code that gets called *very* often, it seemed a
reasonable thing to do.
Signed-off-by: Tomaz Canabrava <tomaz.canabrava@intel.com>
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
Take instantMeanDepthLine out of the code. We have the moving average line
plus the exact data in the information overlay.
Signed-off-by: Cristine Guadelupe <cristineguadelupe@me.com>
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
Correct minor malfunction with CCR setpoint display. It was showing even
when the po2 display was turned off. This patch ensures that the setpoint
graph only shows when the po2 toolbar button is activated (and in addition
the appropriate checkbox in the Preferences).
Signed-off-by: willem ferguson <willemferguson@zoology.up.ac.za>
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
Commits 0de3bc8452 ("Display CCR setpoint values on the po2 graph") and
65eed80e37 ("Don't always show the setpoint graph") didn't take into
account that current_dive could be NULL and therefore accessing current_dc
could crash.
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
When a CCR dive is viewed and the toolbar button for PO2 is activated,
both the PO2 (green line) and the O2 setpoint (red line) are shown.
This allows evaluation of the PO2 in the CCR loop with respect to the
pre-configured O2 setpoint.
The setpoint graph can be disabled from the Preferences/Graphs tab
by checking the appropriate checkbox.
Signed-off-by: willem ferguson <willemferguson@zoology.up.ac.za>
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
Flat mean depth line (whole dive, not the instant one) is redundant as we now
have a much more useful mean depth graph.
Signed-off-by: Krzysztof Arentowicz <k.arentowicz@gmail.com>
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
As we already have running depth sum values for each sample
why don't just plot running average depth graph.
Signed-off-by: Krzysztof Arentowicz <k.arentowicz@gmail.com>
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
This class will hold the visible line of the mean depth for the time 'now'
Signed-off-by: Tomaz Canabrava <tomaz.canabrava@intel.com>
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
This creates a destructor for ProfileWidget2 that deletetes its new'ed
objects on exit.
Signed-off-by: Anton Lundin <glance@acc.umu.se>
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
Since replotting is expensive and it is triggered while scrolling
through the list of cylinders, better not do it for improved
user experience and replot only after the combo box loses
focus.
I hope this...
Fixes#768
Signed-off-by: Robert C. Helling <helling@atdotde.de>
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
Depending on the options shown, the latest change appears to have moved
the temperature graph a bit too low. This seems to work better in my
experiments.
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
A profiler session in the planner shows that for deep long dives
a significant amount of CPU time is spent in populate_pressure_information()
which interpolates the cylinder pressure graphs.
This patch introduces a "fast" flag for the replot of the profile
which is active while the mouse button is still pressed and that
suppresses this calculation.
In the future, this flag could be used for other responsiveness tunings
of the plot.
Signed-off-by: Robert C. Helling <helling@atdotde.de>
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
This patch adds a context menu entry to add a setpoint change
event. In particular, this can be used to turn a logged dive into
a CCR dive.
Signed-off-by: Robert C. Helling <helling@atdotde.de>
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
This code sets up the UI that will allow the user to adjust tank pressures
at a gaschange event. The actual changing of the pressure is not
implemented, yet, so this is disabled until someone finds time to do so.
The scenario is this: a tec diver or sidemount diver without pressure
sensors on at least one of their tanks still wants to reasonably
accurately track gas consumption during a dive. The diver takes notes of
the pressures at every tank switch (I find that odd, but apparently some
cave divers indeed do that as they switch back and forth between different
gases) and then wants to adjust the pressures in Subsurface to match those
written down.
One difficulty here is that the first and last pressure of a tank with no
sensor data is still considered "sensor pressure" - this is basically an
implementation detail in the code that is used to do the pressure
interpolation to have constant-SAC pressure plots for tanks without
sensors. So when we check if there is indeed no pressure data available at
the gas change, we can't just work with the interpolated pressure - if
this is the first (or last) time the tank was used, that pressure may be
marked as sensor pressure.
What's missing is the UI to enter the desired new pressure plus the black
magic that actually inserts this into the dive in a way that doesn't break
the assumptions in the rest of the code. I'm running out of time to do
that but wanted to preserve this code so someone can continue this later.
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
We had the variable. As a pointer. Which we used memset to clear. Ouch -
that smells like some bad cut and paste.
With this change the object keeps the corresponding plotInfo around (just
like some others do) and can use it later. I suspect this code could use
some larger cleanup, but it's a bit too late for this in the development
cycle, I guess. I'm sure I'll regret this in the future...
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
In the context menu of the profile it makes no sense to offer the ability
to switch gases unless there is a gas to switch to.
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
Since we only store things in the preferences if they are different from
the default, the existing code that simply compared with the settings
value didn't work when people used the defaults.
We now compare to the actual preference at runtime which should address
that.
Fixes#731
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>