Commit graph

56 commits

Author SHA1 Message Date
Dirk Hohndel
d87a606039 Correctly handle air in the deco code
We mark air with o2.permille = 0. But it's actually 20.9% O2.

Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
2013-01-04 23:09:04 -08:00
Dirk Hohndel
6dc247ff78 Fix deco calculations to correctly use GF values and add CC support
The old implementation was broken in several ways.

For one thing the GF values are percentages, so they should normally be
0 < GF < 1 (well, some crazy people like to go above that).

With this most of the Bühlmann config constants were wrong.

Furthermore, after we adjust the pressure tolerance based on the gradient
factors, we need to convert this back into a depth (instead of passing
back the unmodified depth - oops).

Finally, this commit adds closed circuit support to the deco calculations.

Major progress and much more useful at this stage.

Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
2013-01-04 11:13:14 -08:00
Dirk Hohndel
9cd18c43aa Make GF values configurable
There are a couple of issues with this commit:

GtkEntry should emit the 'changed' signal when it is modified (so that
changes in the preferences get applied right away) - but that doesn't
appear to be working consistently.

Also, this doesn't appear to affect the deco of any dives that I try it
with. So my guess is something is wrong with the underlying deco
algorithm. That's diappointing.

Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
2013-01-03 21:41:35 -08:00
Dirk Hohndel
2c33603256 Consider previous dives when calculating deco
This also initializes the N2 tissue saturations to correct numbers
(setting them to zero was clearly silly).

With this commit we walk back in the dive_table until we find a surface
intervall that's longer than 48h. Or a dive that comes after the last one
we looked at; that would indicate that this is a divelist that contains
dives from multiple divers or dives that for other reasons are not
ordered. In a sane environment one would assume that the dives that need
to be taken into account when doing deco calculations are organized as one
trip in the XML file and so this logic should work.

One major downside of the current implementation is that we recalculate
everything whenever the plot_info is recreated - which happens quite
frequently, for example when resizing the window or even when we go into
loup mode. While this isn't all that compute intensive, this is an utter
waste and we should at least cache the saturation inherited from previous
dives (and clear that number when the selected dive changes). We don't
want to cache all of it as the recreation of the plot_info may be
triggered by the user changing equipment (and most importantly, gasmix)
information. In that case the deco data for this dive does indeed have to
be recreated. But without changing the current dive the saturation after
the last surface intervall should stay the same.

Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
2013-01-03 20:45:20 -08:00
Dirk Hohndel
5ba250bd48 Use gradient factors in deco calculation
Usually dive computers show the ceiling in terms of the next deco stop -
and those are in 3m increments. This commit also adds the ability to chose
either the typical 3m increments or the smooth ceiling that the Bühlmann
algorithm actually calculates.

Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
2013-01-03 20:44:37 -08:00
Dirk Hohndel
3c31d0401d First stab at deco calculations
This seems to give us roughly the right data but needs a lot more testing.

Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
2013-01-03 20:43:14 -08:00