Commit graph

211 commits

Author SHA1 Message Date
Linus Torvalds
d7925dac44 Do a better job at creating plot info entries
This simplifies - and improves - the code to generate the plot info
entries from the samples.

We used to generate exactly one plot info entry per sample, and then -
because the result doesn't have high enough granularity - we'd
generate additional plot info entries at gas change events etc.

Which resulted in all kinds of ugly special case logic. Not only for
the gas switch, btw: you can see the effects of this in the deco graph
(done at plot entry boundaries) and in the gas pressure curves.

So this throws that "do special plot entries for gas switch events"
code away entirely, and replaces it with a much more straightforward
model: we generate plot entries at a minimum of ten-second intervals.
If you have samples more often than that, you'll get more frequent
plot entries, but you'll never get less than that "every ten seconds".

As a result, the code is smaller and simpler (99 insertions, 161
deletions), and actually does a better job too.

You can see the difference especially in the test dives that only have
a few entries (or if you create a new dive without a dive computer,
using the "Add Dive" menu entry). Look at the deco graph of test-dive
20 before and after, for example. You can also see it very subtly in
the cylinder pressure curves going from line segments to curves on
that same dive.

Signed-off-by: Linus Torvalds <torvalds@linux-foundation.org>
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
2013-01-06 14:42:19 -08:00
Linus Torvalds
635f190302 Fix profile display for dives with no samples
For dives with no samples, we crate a fake dive computer with a set of
made-up samples and use those to display the profile.

However, the actual calculations to do the maximum duration and depth
etc were always done with the "real" dive information, which is empty.
As a result, the scale of the plot ended up being bogus, and part of
the dive would be missing.

Trivially fix by just passing the same dive computer information to
calculate_max_limits() that we use for everything else.

Signed-off-by: Linus Torvalds <torvalds@linux-foundation.org>
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
2013-01-05 00:18:30 -08:00
Dirk Hohndel
cca847791a First stab at simplistic dive planning
This comes with absolutely no gui - so the plan literally needs to be
compiled into Subsurface. Not exactly a feature, but this allowed me to
focus on the planning part instead of spending time on tedious UI work.

A new menu "Planner" with entry "Test Planner" calls into the hard-coded
function in planner.c. There a simple dive plan can be constructed with
calls to plan_add_segment(&diveplan, duration, depth at the end, fO2, pO2)

Calling plan(&diveplan) does the deco calculations and creates deco stops
that keep us below the ceiling (with the GFlow/high values currently
configured). The stop levels used are defined at the top of planner.c in
the stoplevels array - there is no need to do the traditional multiples of
3m or anything like that.

The dive including the ascents and deco stops all the way to the surface
is completed and then added as simulated dive to the end of the divelist
(I guess we could automatically select it later) and can be viewed.

This is crude but shows the direction we can go with this. Envision a nice
UI that allows you to simply enter the segments and pick the desired
stops.

What is missing is the ability to give the algorithm additional gases that
it can use during the deco phase - right now it simply keeps using the
last gas used in the diveplan.

All that said, there are clear bugs here - and sadly they seem to be in
the deco calculations, as with the example given the ceiling that is
calculated makes no sense. When displayed in smooth mode it has very
strange jumps up and down that I wouldn't expect. For example with GF
35/75 (the default) the deco ceiling when looking at the simulated dive
jumps from 16m back up to 13m around 14:10 into the dive. That seems very
odd.

Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
2013-01-04 23:56:55 -08:00
Dirk Hohndel
1b22ac16f2 Clean up DEBUG code
It's still a mess (and the symbols aren't used consistently), but it's a
tiny bit more logical...

Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
2013-01-04 11:56:43 -08:00
Dirk Hohndel
65c85b39ea Make sure that the calculated deco ends at 0
Without this the cairo_close_path call could do silly looking things
(intersecting polygons...).

Reported-by: "Robert C. Helling" <helling@atdotde.de>
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
2013-01-04 11:54:38 -08:00
Dirk Hohndel
6dc247ff78 Fix deco calculations to correctly use GF values and add CC support
The old implementation was broken in several ways.

For one thing the GF values are percentages, so they should normally be
0 < GF < 1 (well, some crazy people like to go above that).

With this most of the Bühlmann config constants were wrong.

Furthermore, after we adjust the pressure tolerance based on the gradient
factors, we need to convert this back into a depth (instead of passing
back the unmodified depth - oops).

Finally, this commit adds closed circuit support to the deco calculations.

Major progress and much more useful at this stage.

Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
2013-01-04 11:13:14 -08:00
Dirk Hohndel
2c33603256 Consider previous dives when calculating deco
This also initializes the N2 tissue saturations to correct numbers
(setting them to zero was clearly silly).

With this commit we walk back in the dive_table until we find a surface
intervall that's longer than 48h. Or a dive that comes after the last one
we looked at; that would indicate that this is a divelist that contains
dives from multiple divers or dives that for other reasons are not
ordered. In a sane environment one would assume that the dives that need
to be taken into account when doing deco calculations are organized as one
trip in the XML file and so this logic should work.

One major downside of the current implementation is that we recalculate
everything whenever the plot_info is recreated - which happens quite
frequently, for example when resizing the window or even when we go into
loup mode. While this isn't all that compute intensive, this is an utter
waste and we should at least cache the saturation inherited from previous
dives (and clear that number when the selected dive changes). We don't
want to cache all of it as the recreation of the plot_info may be
triggered by the user changing equipment (and most importantly, gasmix)
information. In that case the deco data for this dive does indeed have to
be recreated. But without changing the current dive the saturation after
the last surface intervall should stay the same.

Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
2013-01-03 20:45:20 -08:00
Dirk Hohndel
5ba250bd48 Use gradient factors in deco calculation
Usually dive computers show the ceiling in terms of the next deco stop -
and those are in 3m increments. This commit also adds the ability to chose
either the typical 3m increments or the smooth ceiling that the Bühlmann
algorithm actually calculates.

Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
2013-01-03 20:44:37 -08:00
Dirk Hohndel
aab67e2a5b Add configurable visualization of calculated ceiling
This is on top of the deco information reported by the dive computer (in a
different color - currently ugly green). The user needs to enable this via
the Tec page of the preferences.

Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
2013-01-03 20:43:19 -08:00
Dirk Hohndel
3c31d0401d First stab at deco calculations
This seems to give us roughly the right data but needs a lot more testing.

Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
2013-01-03 20:43:14 -08:00
Dirk Hohndel
8f364d0094 Use the Left and Right keys to switch between divecomputers
The existing code had the somewhat retarded Ctrl-C binding for displaying
the next divecomputer and no way to go back to the previous one. With this
commit we use our keyboard grab to map Left and Right to previous and next
divecomputer. Much nicer.

Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
2013-01-01 10:20:22 -08:00
Linus Torvalds
d720e133d8 First step in cleaning up cylinder pressure sensor logic
This clarifies/changes the meaning of our "cylinderindex" entry in our
samples. It has been rather confused, because different dive computers
have done things differently, and the naming really hasn't helped.

There are two totally different - and independent - cylinder "indexes":

 - the pressure sensor index, which indicates which cylinder the sensor
   data is from.

 - the "active cylinder" index, which indicates which cylinder we actually
   breathe from.

These two values really are totally independent, and have nothing
what-so-ever to do with each other. The sensor index may well be fixed:
many dive computers only support a single pressure sensor (whether
wireless or wired), and the sensor index is thus always zero.

Other dive computers may support multiple pressure sensors, and the gas
switch event may - or may not - indicate that the sensor changed too. A
dive computer might give the sensor data for *all* cylinders it can read,
regardless of which one is the one we're actively breathing. In fact, some
dive computers might give sensor data for not just *your* cylinder, but
your buddies.

This patch renames "cylinderindex" in the samples as "sensor", making it
quite clear that it's about which sensor index the pressure data in the
sample is about.

The way we figure out which is the currently active gas is with an
explicit has change event. If a computer (like the Uemis Zurich) joins the
two concepts together, then a sensor change should also create a gas
switch event. This patch also changes the Uemis importer to do that.

Finally, it should be noted that the plot info works totally separately
from the sample data, and is about what we actually *display*, not about
the sample pressures etc. In the plot info, the "cylinderindex" does in
fact mean the currently active cylinder, and while it is initially set to
match the sensor information from the samples, we then walk the gas change
events and fix it up - and if the active cylinder differs from the sensor
cylinder, we clear the sensor data.

[Dirk Hohndel:  this conflicted with some of my recent changes - I think
		I merged things correctly...]

Signed-off-by: Linus Torvalds <torvalds@linux-foundation.org>
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
2012-12-30 20:44:47 -08:00
Dirk Hohndel
e3ab1c0701 Update deco handling
This commit makes deco handling in Subsurface more compatible with the way
libdivecomputer creates the data. Previously we assumed that having a
stopdepth or stoptime and no ndl meant that we were in deco. But
libdivecomputer supports many dive computers that provide the deco state
of the diver but with no information about the next stop or the time
needed there. In order to be able to model this in Subsurface this adds an
in_deco flag to the samples. This is only stored to the XML file when it
changes so it doesn't add much overhead but will allow us to display some
deco information on dive computers like the Atomic Aquatics Cobalt or many
of the Suuntos (among others).

The commit also removes the old event based deco code that was commented
out already. And fixes the code so that the deco / ndl information is
stored for the very last sample as well.

Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
2012-12-30 18:17:21 -08:00
Dirk Hohndel
2581b3870f Make the tooltip text for gaschange events more informative
We now print out "air", "nn% O2", or "(nn/xx)" for trimix.

Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
2012-12-29 11:44:11 -08:00
Dirk Hohndel
e726c9d65c Add settings section to XML file format and store dive computer IDs
We only store the model/deviceid/nickname for those dive computers that
are mentioned in the XML file. This should make the XML files nicely
selfcontained.

This also changes the code to consistently use model & deviceid to
identify a dive computer. The deviceid is NOT guaranteed to be collision
free between different libdivecomputer backends...

Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
2012-12-26 16:46:21 -08:00
Dirk Hohndel
8d2abc05f6 Remove nickname from divecomputer data structure
Having it there with the model information seemed to make sense but on
second thought it's the wrong spot to keep that information, especially
since we were storing it in the XML file in every single dive.

This change removes the nickname member from the divecomputer and makes
the rest of the code reasonably self consistent. It does not add much of
the new code for the new design to handle nicknames.

Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
2012-12-21 20:58:47 -08:00
Linus Torvalds
d8fd8b2099 Add a "View next dive computer" menu item
This adds the capability to actually view all your dive computers, by
adding a menu item under "Log"->"View"->"Next DC" to show the next dive
computer.

Realistically, if you actually commonly use this, you'd use the
accelerator shortcut.  Which right now is Ctrl-C ("C for Computer"),
which is probably a horrible choice.

I really would want to have nice "next/prev dive" accelerators too,
because the cursor keys don't work very well with the gtk focus issues.
Being able to switch between dives would also make the "just the dive
profile, maam" view (ctrl-2) much more useful.

The prev/next dive in the profile view should probably be done with a
keyboard action callback, which also avoids some of the limitations of
accelerators (ie you can make any key do the action).  Some gtk person,
please?

Anyway, this commit only does the dive computer choice thing, and only
using the accelerators.

Signed-off-by: Linus Torvalds <torvalds@linux-foundation.org>
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
2012-12-17 08:29:39 -10:00
Dirk Hohndel
a691a8e5a3 Improve visual appearance of horizontal marker lines
This changes two things to improve the appearance of the profile:
- the partial pressure scale is now in 0.5 increments if the total is <= 4
  and in 1.0 increments if it is > 4.
- the depth marker lines end slightly below the depth chart so that we no
  longer have overlap between the depth scale and the partial pressure
  scale.

Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
2012-12-16 22:05:11 -10:00
Lubomir I. Ivanov
33ae98c96f Attempt to free plot data entries in each call to create_plot_info()
In profile.c:create_plot_info(), store the last address in which
memory was allocated for the plot data entries in the static
variable "last_pi_entry". If "last_pi_entry" isn't a NULL
pointer in each call to create_plot_info(), free memory at that
address.

Signed-off-by: Lubomir I. Ivanov <neolit123@gmail.com>
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
2012-12-16 16:00:09 -10:00
Dirk Hohndel
713a4fcff6 Add the ability to set a nickname for a dive computer
We maintain a list of dive computers that we know about (by deviceid) and
their nicknames in our config. If the user downloads dive from a dive
computer that we haven't seen before, we give them the option to set a
nickname for that dive computer. That nickname is displayed in the profile
(and stored in the XML file, assuming it is not the same as the model).

This implementation attempts to make sure that it correctly deals with
utf8 nicknames.

Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
2012-12-13 21:33:30 -10:00
Dirk Hohndel
0b69bd474d Only display a depth scale appropriate for the depth of the dive
Showing the depth scale all the way to the bottom of the profile plot
looks strange when there are partial pressure graphs down there. So
instead we only plot down to the next marker below the maximum depth of
the actual dive.

Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
2012-12-11 15:58:37 -08:00
Dirk Hohndel
c26fa209e3 Show CNS value in the profile mouseover
If we have per-sample CNS values, then show them in the profile tooltip.

Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
2012-12-11 13:40:49 -08:00
Dirk Hohndel
91577f11b5 Merge branch 'cns' into cns-merge
I foolishly changed visible_columns in both the (ill-named) cns branch and
master...

Signed-off-by: Dirk Hohndel <dirk@hohndel.org>

Conflicts:
	divelist.c
	gtk-gui.c
	profile.c
2012-12-11 13:09:48 -08:00
Linus Torvalds
c6ca263fb0 Calculate dive maxima/minima independent of dive computer
This splits the dive time, depth, pressure and temperature maxima and
minima setup from the per-dive-computer "create_plot_info()" function
into one setup function that walks _all_ the dive computers, so that we
have a global maxima and minima.

That way the graph scaling we set up will now fit the data from all dive
computers rather than just the particular one we are plotting.  So if
you switch back-and-forth between computers, the scale (which is defined
by the extremes) remains the same.

Signed-off-by: Linus Torvalds <torvalds@linux-foundation.org>
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
2012-12-11 11:04:18 -08:00
Dirk Hohndel
0ae16899de Don't draw tooltips if no profile is displayed
This fixes ticket 33

Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
2012-12-10 11:02:33 -08:00
Dirk Hohndel
92c0d8c516 Move global variables covered by Preferences into one structure
Now we can simply remember the state of all the preferences at the
beginning of preferences_dialog() and restore them if the user presses
'Cancel'.

Fixes #21

Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
2012-12-10 10:26:06 -08:00
Dirk Hohndel
9463e7895b Don't print partial pressure values in the profile
Instead provide a scale on the right in a highly transparent grey and rely
on the tooltip available with mouse-over to pinpoint the value at certain
spots with much better accuracy.

Fixes #30

Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
2012-12-09 14:36:56 -08:00
Dirk Hohndel
8dfc4dccc5 Don't print an initial gaschange event that just tells us the gas used
Some dive computers appear to tell us the gas used in a gaschange event
right at the beginning of the dive. We arbitrary have a cut-off that says
"a gas change in the first 30 seconds shouldn't get a marker".

Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
2012-12-08 21:23:45 -08:00
Dirk Hohndel
07b74007f1 Correct partial pressure calculations
Regardless what the dive computer tells us, don't believe that pO2 was
higher than the ambient pressure. This gives much more realistic values.

Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
2012-12-08 21:23:45 -08:00
Dirk Hohndel
02844c3a10 Correctly parse the two different gas change events
This now takes the He percentage into account when matching tanks. Given
the encoding of fO2 and fHe in the GASCHANGE2 event, we can simply mask
and shift as if we have a GASCHANGE2 event and things will automatically
work correctly for the regular GASCHANGE event.

Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
2012-12-08 21:23:27 -08:00
Dirk Hohndel
9bcd21bf67 Draw pO2 profile last
This way it sits on top of the other partial pressure plots and is a bit
easier to read.

Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
2012-12-08 14:07:10 -08:00
Dirk Hohndel
40d05ed768 Show two decimal digits in pO2, pN2 and pHe in the tooltip
Tec divers seem to like a little bit more precision - and the dive
computers certainly provide it (or we can calculate it).

Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
2012-12-08 13:58:14 -08:00
Dirk Hohndel
3b425b4c13 Plot pO2 graph based on sample information, if available
This should give closed circuit divers with a supported dive computer
correct partial pressure plots.

Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
2012-12-07 21:05:21 -08:00
Dirk Hohndel
a0f28aa422 Add option to make ceiling visually stand out more in the profile
While having the background "come down" seemed like a good visualization
of the ceiling, some divers appear to prefer something more dramatic. This
adds an option to the Tec Settings to have the ceiling shown in red
instead of the default background color.

Suggested-by: Jan Schubert <Jan.Schubert@GMX.li>
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
2012-12-07 11:39:15 -08:00
Dirk Hohndel
982abb5596 Move partial pressure plots up slightly
This way they don't clash with the dive computer model information that
was added by commit a23ec27ca7bb "Add dive computer name to the dive
plot".

Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
2012-12-07 10:49:02 -08:00
Linus Torvalds
0d1f396f3a Move 'plot_info' into 'struct graphics_context'
.. and then allocate just the plot-info entry array dynamically.

We want to have a longer lifetime for the basic plot_info data
structure, because we want to do computer selection and maximum
time/depth/temperature computations *before* we start plotting anything,
and before we allocate the plot entry array.

Signed-off-by: Linus Torvalds <torvalds@linux-foundation.org>
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
2012-12-07 10:31:26 -08:00
Linus Torvalds
22aa6fa4ef Add dive computer name to the dive plot
I want to have some way to show multiple dive computers, so start off by
adding the name of the current one.  So if we change dive computers,
we'll see it.

Signed-off-by: Linus Torvalds <torvalds@linux-foundation.org>
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
2012-12-07 10:31:22 -08:00
Dirk Hohndel
dcb6574dc4 Improve deco handling and add NDL support
This commit changes the code that was recently introduced to deal with
deco ceilings. Instead of handling these through events we now store the
ceiling (which in reality is the deepest deco stop with all known dive
computers) and the stop time at that ceiling in the samples.

This also adds support for NDL (non stop dive limit) which both dive
computers that appear to give us ceiling / deco information appear to
give us as well (when the diver isn't in deco).

If the mouse hovers over the profile we now add support for displaying the
NDL, the current deco obligation and (if we are able to tell from the
data) whether we are at a safety stop.

Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
2012-12-04 21:05:26 -08:00
Dirk Hohndel
10fac7a6af Updating events for libdivecomputer 0.3 (and tracking uemis support)
I was a little too eager to add the deco feature to Subsurface. Jef and I
went back and forth a few more times and the definition of those events
changed. I guess I shouldn't have commited that code until the
corresponding libdivecomputer code had been pushed.

This commit now brings us in sync with the current master of
libdivecomputer (but should compile with 0.2 as well - only deco events
won't work then).

One issue that I see is that deco / ndl aren't really a good fit for the
event model. I actually disabled the drawing of the little yellow
triangles for ndl events as for example on the Uemis those events are
created whenever the remaining non stop time changes - and that can be
every few seconds.

The correct solution may be to treat this as a function of the samples,
but for now this works and is tested with both OSTC and Uemis SDA.

Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
2012-11-28 21:13:21 -07:00
Linus Torvalds
df3671390d Fix dive computer event handling if there are no samples
This actually triggers for one of our insane test dives (test15): it has
no samples, so we created a fake dive computer entry with the a fake
profile in it, but we didn't copy the events over.

Having a dive with no samples, yet having events from the dive computer,
sounds pretty bogus.  But that test-case did show that when that bogus
situation happens, we had two independent buglets: (a) we didn't insert
the entries in the fake dive computer entry we used and (b) we would
then mix up the events of the fake dive computer entry with the first
dive computer of a dive.

Fix this, just to make test15 happy again.  And eventually, when we
actually plot the information for multiple dive computers, fixing case
(b) would become necessary even for real dives.

Signed-off-by: Linus Torvalds <torvalds@linux-foundation.org>
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
2012-11-26 21:45:38 -07:00
Linus Torvalds
25b4fee655 Move events and samples into a 'struct divecomputer'
For now we only have one fixed divecomputer associated with each dive,
so this doesn't really change any current semantics.  But it will make
it easier for us to associate a dive with multiple dive computers.

Signed-off-by: Linus Torvalds <torvalds@linux-foundation.org>
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
2012-11-23 19:36:27 -08:00
Dirk Hohndel
a154d1ccdc Tweak partial pressure plot to avoid printing values ontop of eachh other
This still can look too busy on shallow long dives with moderate vertical
movement.

Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
2012-11-12 20:01:12 -08:00
Dirk Hohndel
79798dc15b Improve visual appearance of temperature plot
Prervent tiny temperature changes from being exaggerated in the plot.

Also, shift pressure plot around a bit (if necessary) to prevent it from
ending in the same space as the temperature plato on the profile graph.

Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
2012-11-12 18:46:14 -08:00
Dirk Hohndel
ec042222f0 Handle dives without samples correctly
The code in commit f99e1b476b18 "Trim the dive to exclude surface time at
beginning and end" failed rather badly if a dive has no samples at all -
which is true for many of our test dives.

This makes sure that we don't exclude data points if we never set up start
and end times.

Reported-by: Lubomir I. Ivanov <neolit123@gmail.com>
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
2012-11-11 17:56:32 +01:00
Linus Torvalds
7fc1213aab Add back mysteriously deleted "} else {" line
Commit 6c52e8a2e5 ("Add plotting of the deco ceiling") for some
totally unexplained reason deleted one "else" statement, resulting in
some plot events not having a time at all.  Which causes various really
odd issues if you hit that situation, including divide-by-zero etc due
to the difference in times between events being nonsensical.

It's just some odd mistake that was entirely unrelated to the other
changes in that commit.

Add the missing line back in.

Signed-off-by: Linus Torvalds <torvalds@linux-foundation.org>
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
2012-11-11 17:22:18 +01:00
Dirk Hohndel
502e2b0e86 Add more data to our tool-tip display in the profile window
This shows the values for all the graphs that are shown (depth,
temperature, tank pressure, pO2, pN2m pHe), but also correctly doesn't
display them when they are turned off or no data is available (prior to
this commit, tank pressure was always shown, even if no pressure samples
were available for the dive).

Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
2012-11-11 17:18:14 +01:00
Linus Torvalds
80485114ba Fix possible array bound violation for insanely long dives
When we calculate the interval for the tick-marks for the dive, we need
to limit 'i' to be within the size of the array.  The code does that
with a "i < 8" check, but the fact is, we must never increment past the
last entry, which is 7 (the size of the array is 8, but the last valid
index is 7).

This only happens for unrealistically long dives.  Which you can trigger
either by inputting insane values for a manually created dive, or by
merging two dives that are consecutive, but not close to each other
time-wise (eg on different days ;)

Signed-off-by: Linus Torvalds <torvalds@linux-foundation.org>
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
2012-11-11 15:08:56 +01:00
Linus Torvalds
01e8984d7d Create tool-tip with depth/pressure for the whole profile area
This extends on our current tooltip logic (which shows events when you
mouse over them) to show tooltips for the whole profile area.

If you mouse over an event, that is still shown in the tooltip, but
even in the absense of events, the tooltip will be active, and mousing
over the profile area will show the time, depth and pressure.

This can certainly be improved upon further, but even in this form it is
useful.

Fixes #9

Signed-off-by: Linus Torvalds <torvalds@linux-foundation.org>
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
2012-11-11 14:44:10 +01:00
Dirk Hohndel
7c09991876 Trim the dive to exclude surface time at beginning and end
We don't change any of the samples, we just don't plot (or consider for
dive time / mean calculations) the samples at the beginning or end of the
dive that are less than a certain threshold under water. Right now that's
an arbitrary 75cm which seems to Do The Right Thing(tm) for the dives I
tried this with - but I'm happy to look at other values if this causes
problems for people with dive computers I do not have access to.

Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
2012-11-11 10:36:46 +01:00
Dirk Hohndel
e167108c76 Add depth to mbar helper function
This ensures that we use consistent math to get the absolute pressure at a
certain depth.

Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
2012-11-11 08:50:56 +01:00