The latest CCR patches had rendered the planner not usable for CCR dives.
This patch corrects this (and reenables the CCR set point column for
segments). The problem was that a new member setpoint of struct divepoint
had been introduced, but there was already po2 which had the same meaning.
This patch merges the two and renames them setpoint to prevent future
confusion.
Signed-off-by: Robert C. Helling <helling@atdotde.de>
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
fill_o2_values() in profile.c: Robert identified the inconsistency of po2
assignmemts when using OC dives as opposed to CCR dives.
This is corrected here. OC dives still need to be processed in this function
because the po2 values have not been initialised anywhere else before
thos code executes.
Signed-off-by: willem ferguson <willemferguson@zoology.up.ac.za>
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
This patch responds to the side effects that the CCR code has had with
respect to ceilings in OC dives and dive plans. Dive ceilings are now
calculated correctly again.
The following were performed:
1) remove the oxygen sensor and setpoint fields from the gas_pressures
structure.
2) Re-insert setpoint and oxygen sensor fields in the plot_data structure.
3) Remove the algorithm that reads the o2 sensor data and calculates the
pressures.po2 value from function fill_pressures() in dive.c and save
it as a separate function calc_ccr_po2() in profile.c.
4) Activate calc_ccr_po2 from function fill_pressures() in profile.c.
5) Move the relative position of the call to fill_pressures() within the
function create_polt_info_new() in profile.c.
Signed-off-by: willem ferguson <willemferguson@zoology.up.ac.za>
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
This patch adds code to the function fillpressures() in dive.c to
allow calculating o2 pressures, based on the data from the po2
sensors in the system. The following changes were made:
1) add code to perform po2 calculations for CCR with 1, 2 or 3
oxygen sesnors.
2) Add four fields to the gas_pressures structure in dive.h. This
allows communication of data between the function that calls
get_pressures() and the return of partail pressure values to the
calling function.
3) Delete the fields for setpoint and gas partial pressures from
the structure plot_info. All partial pressures (from instruments
as well as calculated) now reside in the pressures structure
that forms part of plot_info.
4) Perform changes in several parts of profile.c to make use of the
pressures structure in plot_info.
[Dirk Hohndel: yet again massive whitespace cleanup]
Signed-off-by: willem ferguson <willemferguson@zoology.up.ac.za>
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
This patch does three things:
1) A new function fill_o2_values() is added to profile.c. This
fills all oxygen sesnsor and setpoint values that have been
zeroed before in order to save space in the dive log. This
recreates the full set of sensor values obtained from the
original CCR xml log file.
2) Function fill_o2_values() is activated in function create_
plot_info_new() in profile.c
3) The calling parameters to function fill_pressures() in dive.c
are changed. The last parameter is now a pointer to a structure
of divecomputer. This will be needed in the last patch of the
present series of three patches.
[Dirk Hohndel: minor whitespace cleanup]
Signed-off-by: willem ferguson <willemferguson@zoology.up.ac.za>
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
Decode the gasmix data into a sane format when creating the event, and
add the (currently unused) ability to specify a gas change to a
particular cylinder rather than (or in addition to) the gasmix.
Signed-off-by: Linus Torvalds <torvalds@linux-foundation.org>
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
This patch allows the importing of oxygen sensor and setpoint data from
Poseidon CCR dive logs.
1) Change parse-xml.c to read up to three oxygen sensor values from xml.
and to store the information in sample structures
2) Change parse-xml.c to read o2 setpoint values fro xml and to store
it in sample structures
3) Change dive.c to delete all sensor and setpoint values where
subsequent samples have sensor/setpoint values that are the same.
4) Change profile.c to store the sensor/setpoint values from the samples
into plotinfo.
5) Change the sample Poseidon xml log in the dives directory to ensure
the correct order and hierarchy of the dive and divecomputer nodes.
[Dirk Hohndel: minor cleanup, removed debug code, whitespace]
Signed-off-by: willem ferguson <willemferguson@zoology.up.ac.za>
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
This adds a graphical representation of tissue loadings at the current moment during the dive
to the tooltip box. The layout is inspired by the Sherwater Petrel.Add tissue saturation plot to tooltip
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
This adds a toolbox icon to turn on a tissue plot inspired by the bar
graph of the Sherwater Petrel,
It shows the inert gas partial pressures for individual compartments. If
they are below the ambient pressure (grey line) they are shown in units of
the ambient pressure, if they are above, the excess is shown as a
percentage of the allowed overpressure for plain Buehlmann. So it has the
same units as a gradient factor. Thus also the a gradient factor line (for
the current depth) is shown.
The different tissues get different colors, greener for the faster ones and bluer
for the slower ones.
Positioning and on/off icon action still need some tender loving care.
Signed-off-by: Robert C. Helling <helling@atdotde.de>
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
This patch introduces a new structure holding partial pressures (doubles in bar) for
all three gases and a helper function to compute them from gasmix (which holds fractions)
and ambient pressure. Currentlty this works for OC and CCR, to be extended later to PSCR.
Currently the dive_comp_type argument is unused.
Signed-off-by: Robert C. Helling <helling@atdotde.de>
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
This patch implements the cylinder pressure calculations for diluent
gas in CCR dive computers. This is the third patch for achieving this.
The following were performed:
1) Add two lines to try_to_fill_sample() in parse-xml so that
diluent cylinder pressures are stored from XML dive log file
into structures of sample.
2) Add one line to populate_plot_entries() in profile.c so that
the diluent cylinder pressures are copied from structures of
sample to structures of plot_info.
3) add three constant #defines in profile.h
4) change populate_pressure_information() in gaspressures.c in
order to take into account pressure calculations for the
diluent cylinder, calling subordinate functions in the
appropriate way.
5) change create_plot_info_new() in profile.c in order to initiate
the pressure calculations for the diluent cylinder.
6) Implement two debugging functions (one in profile.c, another
in gaspressures.c). These debugging functions are activated
by means of #defines.
Two function calls dealing with oxygen pressure are currently commented
out. They will be activated in the following patch that attends to CCR
oxygen partial pressure calculation.
[Dirk Hohndel: rather massive whitespace cleanup]
Signed-off-by: willem ferguson <willemferguson@zoology.up.ac.za>
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
This patch implements a separation of the code for gas pressure
calculations from the rest of the code in profile.c. The latter
file is now split into: profile.c and gaspressures.c. The
details of the transferred functions is given at the top of
gaspressures.c. The following chnages were made:
1) dive.h: The function types of calculate_depth_to_mbar
and depth_to_mbar were made non-static in order to make them
available within gaspressures.c.
2) profile.c: Prototypes for the functions in gaspressures.c
were inserted at the top of profile. Ten functions were
transferred from profile.c to gaspressures.c
3) gaspressures.c as well as a short header, gaspressures.h
were created.
For the gas pressure calculations for CCR dives, gaspressures.c
forms the immediate basis for further code development.
Signed-off-by: Willem Ferguson <willemferguson@zoology.up.ac.za>
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
Since earlier have we had support for our own calculated TTS. This adds
support for holding TTS values reported by a dive computer.
Signed-off-by: Anton Lundin <glance@acc.umu.se>
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
This introduces a limiter that we only calculate deco stop, TTS and NDL
with a minimum of 30s intervall and just reused the values from the
previous sample in other cases.
I run my OSTC3 at 2s sample intervall so this is a 15x speedup in that
case.
Signed-off-by: Anton Lundin <glance@acc.umu.se>
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
Spin boxes for pO2 are now hooked up to preference values. Adding new
cylinders (or changing their fo2) computes the MOD accordin to the current
value of decopo2. Note that chaning the limits for deco pO2 does _not_
automatically update the switch depth of all cylinders as those might have
been manually entered.
Furthermore, MOD has now to option of rounding to multiples of a given
depth. That is used for the automatic switch depth which are now always
multiples of 3m (so that EAN50 is switched to at 21m rather than 22m).
Signed-off-by: Robert C. Helling <helling@atdotde.de>
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
Lets just use pO₂ instead of PO2, ppO2, ppO₂, PO₂.
They all mean the same, but it's better to be
consistent
Signed-off-by: Henrik Brautaset Aronsen <subsurface@henrik.synth.no>
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
Strangely, *prinf() on Linux appears to do the right thing in either
order (my guess is based on the type of the two values?), but on Windows
things go badly.
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
And fix the bug that in the info overlay SAC was always given in metric
values. And try to reduce the number of places in which we calculate the
unit conversions...
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
Add a lager step value when walking the calculations forward.
[Dirk Hohndel: this was sent ages ago and in all the discussions about the
implications I apparently never applied this]
Signed-off-by: Anton Lundin <glance@acc.umu.se>
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
[Dirk Hohndel: this was sent ages ago and in all the discussions about the
implications I apparently never applied this]
Signed-off-by: Linus Torvalds <torvalds@linux-foundation.org>
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
1) All the variables in the sample structures are strongly typed
2) Two additional types were declared in units.h:
o2pressure_t
bearing_t
3) The following variables were added:
diluentpressure
o2setpoint
o2sensor[3]
4) Changes to a number of files were made to chanf
sample->po2 to sample->po2.mbar
bearing to bearring.degrees
Signed-off-by: Willem Ferguson <willemferguson@zoology.up.ac.za>
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
We should never pass permille values around as integers. And we shouldn't
have to decode the stupid value in more than one place.
This doesn't tackle all the places where we access O2 and He "too early"
and should instead keep passing around a gaxmix. But it's a first step.
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
When planning a dive, the dive could use more gas than is in the cylinder.
So getting a negative end pressure is a useful indication to the user that
there plan might not be a good one.
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
We use mod calculations on multiple places, so make a separate helper
from it with proper types.
The "clumsiness" of defining a local variable to pass into the function
and out from it comes from the discrepancies in how c and c++ handles
initializations of variables in a struct.
Thanks goes to Tiago and Linus for pointing me in the right direction.
Signed-off-by: Anton Lundin <glance@acc.umu.se>
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
C specs says that we can safelly free a NULL pointer, so there's no reason
to check if it's null before freeing it.
Signed-off-by: Tomaz Canabrava <tomaz.canabrava@intel.com>
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
SAMPLE_EVENT_GASCHANGE2 is the libdivecomputer name of the event.
Compare with that instead of its int value.
Signed-off-by: Anton Lundin <glance@acc.umu.se>
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
This includes minimum pressure from manually added cylinders to be taken
into account on scaling. Without this, manually added cylinders might
lead to pressure dropping below the Y axis 0 line (e.g. when first
"computerized" cylinder is 220->140 and second, manually added cylinder,
200->50 bar).
Signed-off-by: Miika Turkia <miika.turkia@gmail.com>
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
They happen - maybe the cylinder actually warmed up, or maybe the user
entered just a ending pressure without a starting pressure. Regardless,
just ignore cylinder pressure changes that go up.
Also ignore cylinders with a zero ending pressure: that's really a
*missing* pressure rather than an actual zero pressure. As Dirk says,
the scuba regulators don't even work without a healthy positive pressure
differential, so even when you breathe down a tank to "empty", it won't
be at zero pressure (this is true even with gauge pressure, where zero
means "atmospheric pressure").
Signed-off-by: Linus Torvalds <torvalds@linux-foundation.org>
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
-Renaming prefs members for consistency.
-Changing references of QSettings to the prefs structure instead.
-Removing unused functions in pref.h were left over from an old version.
-Changing the data-type of bool members to short for consistency with other members.
Signed-off-by: Gehad elrobey <gehadelrobey@gmail.com>
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
Adds new push button "HR" to the button bar on the dive profile to
toggle display of heart rate.
TODO: New icon for the heart rate button is needed.
Fixes#485
Signed-off-by: Lakshman Anumolu <acrlakshman@gmail.com>
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
This needs to be tracked in the documentation as well.
Signed-off-by: Robert C. Helling <helling@atdotde.de>
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
The selection logic was a bit random: some places would return NULL if
the dive computer index was out of range, others would return the
primary dive computer, and actually moving between dive computers would
just blindly increment and decrement the number.
This always selects the primary computer if the index is out of bounds,
and makes sure we stay in bound when switching beteen dive computers
(but switching between dives can then turn an in-bound number into an
out-of-bounds one)
Fixes#464
Signed-off-by: Linus Torvalds <torvalds@linux-foundation.org>
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
This is just removal of dead code from the old profile, probably there's
still a bit more to remove, but this is a very good cleanup already.
Signed-off-by: Tomaz Canabrava <tomaz.canabrava@intel.com>
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
We should never read cur_pr[cyl] if cyl isn't used during a dive - but for
cylinders that are used cur_pr[cyl] is initialized. But just to catch
errors elsewhere, let's not leave cur_pr[cyl] uninitialized.
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
tissue_tolerance wasn't used after it was assigned.
type was overwritten after it was assigned.
serial was overwritten after the last /= 100.
event is assigned in the for loop.
clear isn't used after the assignment
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
Minor change to the perl postprocessing script and resulting changes to
the affected source files.
This deals with two issues:
- "foreach"-like structures were not always treated correctly
- some longer calculations that ended on "+ constant" were reformatted in
a rather unatractive manner
In one source file (divelist.c) I ended up adding braces to the sources...
trying to cascade the indentation further down without having the block
there seemed a lot more trouble than it's worth.
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
I know everyone will hate it.
Go ahead. Complain. Call me names.
At least now things are consistent and reproducible.
If you want changes, have your complaint come with a patch to
scripts/whitespace.pl so that we can automate it.
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
This patch makes the 'Zoomed Plot' a preference that can be stored and
retrieved, this way if the user sets the plot to be 'zoomed', this
information will persist even if they closed or opened subsurface again.
Also, added the 'Scale' button on the new profile, but didn't did the glue
code yet.
Signed-off-by: Tomaz Canabrava <tomaz.canabrava@intel.com>
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
There should be a space between the colon and the value in the information
box in the profile. The vertical speed should have only one digit after
the decimal point.
Fixes#443
Signed-off-by: Andrey Zhdanov <andrjufka@gmail.com>
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
We use the plot_info as basis for our dataModel in the new profile. In
order to be able to place events at the right spot we need to have a
plot_info entry when the event happens. So let's add interpolated entries
not only based on time but also whenever there's an event between them.
This should address Robert's comment in commit 0474fe70fc ("New profile:
add image pixmaps for image events").
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
This will make no difference when we remove the old profile, but for now I
worry that this could cause us trouble.
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
rint() is "round to nearest integer", and does a better job than +0.5
(followed by the implicit truncation inherent in integer casting). We
already used 'rint()' for values that could be negative (where +0.5 is
actively wrong), let's just make it consistent.
Of course, as is usual for the messy C math functions, it depends on the
current rounding mode. But the default round-to-nearest is what we want
and use, and the functions that explicitly always round to nearest
aren't standard enough to worry about.
Signed-off-by: Linus Torvalds <torvalds@linux-foundation.org>
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>