Commit graph

499 commits

Author SHA1 Message Date
Dirk Hohndel
ea8de175a7 Remove unused function
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
2017-08-26 12:19:48 -07:00
Dirk Hohndel
abc6c7d2b3 Assignment instead of test for equality
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
2017-08-26 12:17:19 -07:00
Dirk Hohndel
a8194fddc5 Time is unsigned here
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
2017-08-26 12:15:43 -07:00
Dirk Hohndel
0813d2168a Remove some unused variables
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
2017-08-26 12:14:46 -07:00
Dirk Hohndel
d6c013f303 Hide signed/unsigned comparison warning
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
2017-08-26 09:38:52 -07:00
Miika Turkia
fb151df883 Shearwater Perdix
Reportedly the case 2 corresponds to Perdix, so it might be that both
Petrel and Perdix use same model number (or the model is mistaken
before).

Signed-off-by: Miika Turkia <miika.turkia@gmail.com>
2017-08-24 13:06:50 -07:00
Miika Turkia
a20aa850da Support for air pressure on Shearwater Desktop import
Fixes #548

Signed-off-by: Miika Turkia <miika.turkia@gmail.com>
2017-08-24 13:06:50 -07:00
Miika Turkia
7d22b52afc Grab correct dive number on Shearwater Desktop import
Signed-off-by: Miika Turkia <miika.turkia@gmail.com>
2017-08-24 13:06:50 -07:00
Dirk Hohndel
5de49401c8 Improve error message when opening dive computer fails
Instead of the (usually incorrect) text about insufficient privileges,
just mention a generic error and suggest that the user creates a
libdivecomputer log file.

Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
2017-08-21 08:13:19 -07:00
Linus Torvalds
6554e4f21e Update the OSTC dive computer configuration to use the generic 'timesync' interface
Jef made the OSTC interface be a generic 'dc_device_timesync()' and so
the old OSTC-specific code doesn't exist any more.

Signed-off-by: Linus Torvalds <torvalds@linux-foundation.org>
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
2017-08-20 21:03:52 -07:00
Jan Mulder
a072c635bc fix weights rounding
Simplify and fix prestation of weights. Due to the attempt to round
only the grams part (by just adding 50 to it, and truncating
afterwards) a weird effect was introduced. For example, a value
0.98 was presented as 0.10. Just replay the old logic, and see
what happens. Rewrote the logic to a simpler and better one.

fixes: #532

Signed-off-by: Jan Mulder <jlmulder@xs4all.nl>
2017-08-10 09:13:26 -07:00
Anton Lundin
9f290dcdb0 DLF: Parse more measurements, import GPS
This add support for parsing more measurements, and now imports GPS data
to.

Signed-off-by: Anton Lundin <glance@acc.umu.se>
2017-08-10 09:09:53 -07:00
Anton Lundin
070c7e545b DLF: Parse Divesoft Liberty data better
There is something with ndl / tts / temp in the Liberty DLF files. If
that bit is set, the values are bogus. There is something more to it
here which I haven't figured out.

Signed-off-by: Anton Lundin <glance@acc.umu.se>
2017-08-10 09:09:53 -07:00
Anton Lundin
8f6f9cd39d DLF: Parse diluent changes as a gaschange event
Signed-off-by: Anton Lundin <glance@acc.umu.se>
2017-08-10 09:09:53 -07:00
Anton Lundin
f0303802dd DLF: Import setpoint changes.
Signed-off-by: Anton Lundin <glance@acc.umu.se>
2017-08-10 09:09:53 -07:00
Anton Lundin
366ad82a98 DLF: Restructure loop into a for loop
We always step forward 16 bytes, so make it a for loop so a continue
won't throw us into a eternal loop.

Signed-off-by: Anton Lundin <glance@acc.umu.se>
2017-08-10 09:09:53 -07:00
Anton Lundin
d77de11a1d configure ostc3: Correct code for right button
Back when I wrote this code I made a typo. This fixes it.

Reported-By: Alexander Gottwald <jugendtrainingtsck@gmail.com>
Signed-off-by: Anton Lundin <glance@acc.umu.se>
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
2017-08-04 09:50:44 -07:00
Linus Torvalds
8fe24055f0 Fix Poseidon MkVI txt file import sensor pressures
When I unified the sample pressures in commit 11a0c0cc70 ("Unify
sample pressure and o2pressure as pressure[2] array") I did all the
obvious conversions, including the conversion of the Poseidon txt file
import:

        case POSEIDON_PRESSURE:
-               sample->cylinderpressure.mbar = lrint(val * 1000);
+               sample->pressure[0].mbar = lrint(val * 1000);
                break;
        case POSEIDON_O2CYLINDER:
-               sample->o2cylinderpressure.mbar = lrint(val * 1000);
+               sample->pressure[1].mbar = lrint(val * 1000);
                break;

which was ObviouslyCorrect(tm).

But as so often is the case, obvious doesn't actually exist.  The old
"o2cylinderpressure[]" model had an implicit sensor associated with it,
and that implicit sensor mapping wasn't obvious, and didn't get fixed.

It turns out that the way the Poseidon sensor mapping works, the O2
cylinder is cylinder 0, and the diluent cylinder is cylinder 1, so just
use the add_sample_pressure() helper to set both sensor index and
pressure value.

And since we now do all the sensor indexing right, we can also get rid
of some manual cylinder sample pressure code, because the generic dive
fixup will just DTRT.  It used to screw up because the diluent sensor
number was wrong before, and the import code tried to work around that
by hand.

Reported-by: Anton Lundin <glance@acc.umu.se>
Signed-off-by: Linus Torvalds <torvalds@linux-foundation.org>
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
2017-08-03 13:29:25 -07:00
Robert C. Helling
c979d9f166 Always show the ascent to the initial deco stop
...even when not showing transitions, this makes the
first stop look more like a stop (since it does not include
several minutes of ascent).

Signed-off-by: Robert C. Helling <helling@atdotde.de>
2017-08-03 11:17:33 -07:00
Anton Lundin
a717cb3a41 android: access() is declared in unistd.h
Calling access() makes no sense at all on android, but this atleast
fixes a compilation error on ndk 15+.

Signed-off-by: Anton Lundin <glance@acc.umu.se>
2017-08-01 13:39:35 -07:00
Anton Lundin
7c6fa227ea Null check before writing to pointer
In the serial api for libdivecomputer is ok to send NULL as the int
pointer actual, if you dont't care about how many bytes that where
actually read or written.

This makes sure we don't crash if the ble backend where ever used with
such a backend.

Signed-off-by: Anton Lundin <glance@acc.umu.se>
2017-08-01 13:39:35 -07:00
Linus Torvalds
56c206d19f For more manual gas pressure details
So the manual gas pressure case keeps showing issues, and in many ways it
really is a fairly complex thing, since it needs interpolation of the
intermediate pressures - possibly over several gas changes.

So you might have beginning and ending pressures for one cylinder, but
then use another cylinder in between.

We've historically got all the code to do this, but the big rewrite for
multiple cylinder pressures didn't get all the details right, and so
here's a few more fixes for the case that was shown by a dive by Robert
Helling.  Hopefully we're approaching the old code situation, except now
with concurrent gas pressure handling support.

Reported-by: Robert Helling <helling@atdotde.de>
Signed-off-by: Linus Torvalds <torvalds@linux-foundation.org>
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
2017-07-30 21:28:34 -07:00
Linus Torvalds
8f0d71ce2b Fix another cylinder pressure plotting special case
The core to plot manually entered pressures without any sample data did
the obvious thing: it ended the pressures at the end of the dive as
indicated by the last sample.

However, that obvious thing didn't actually work, because sometimes the
last sample is long long after the dive has actually ended, and we have
no plot_info data for that.

This depends on the dive computer used: most dive computers will not
report samples after the end (even if they may internally remember them
in case the diver just came up to the surface temporarily), but some
definitely do. The OSTC3 is a prime example of that.

Anyway, the code was fragile and wrong - even if passed a time past the
end of the plot_info data, "add_plot_pressure()" should just have
associated that with the last entry instead.  Which also allows us to
simplify the whole endtime logic entirely, and just use INT_MAX for it.

Gaetan Bisson's test-case also showed another oddity: we would plot the
gas pressure even for cylinders that had no has use (ie beginning and
ending pressures were the same).  That's kind of pointless in so many
ways.  So limit the manual pressure population to cylinders that
actually have seen use.

Reported-by: Gaetan Bisson <bisson@archlinux.org>
Signed-off-by: Linus Torvalds <torvalds@linux-foundation.org>
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
2017-07-30 16:37:45 -07:00
Lubomir I. Ivanov
5b28fcea3a worldmap-save: don't use an API key
The Google Maps API V3 *does* require a key if one needs to generate
a lot of payed trafic and monitor said trafic, otherwise it doesn't:
https://stackoverflow.com/a/8785844

Signed-off-by: Lubomir I. Ivanov <neolit123@gmail.com>
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
2017-07-30 16:28:30 -07:00
Jan Mulder
e76f527fe5 Correctly create cloud account from mobile
The creation of a cloud account from mobile was broken. This fixes
it. Basically, we need to go online for a moment, and setup a correct
local and remote repo for the cloud storage.

Tested for the following scenarios: 1) inital account creation
including PIN handling from mobile, from a clean install .
2) open an already validated cloud account from a clean install.
3) open no-cloud style local account.
4) Switch between 2 already validated could accounts.
5) Try to create a cloud account without data connection.

Notice that scenario 4) does not work perfectly. A restart of
the app is needed to see the new logbook. So that is to be fixed.

Scenario 5) seems a non realistic corner case. This does not work
in a gracefull way. The user needs to remove the app, install it
again, and retry with data connection.

Further notice this is backgroud/core processing only. So no QML UI
changes as proposed (for example) bij Davide.

Signed-off-by: Jan Mulder <jlmulder@xs4all.nl>
2017-07-29 08:30:08 -07:00
Jan Mulder
794739b4c0 strstr is a case sensitive compare
strstr is a case sensitive compare and the string reported from
libgit2 reads "reference" and not "Reference". Further investigation
reveals commit 909d5494368a0080 of libgit2. Here, the change is
made from Reference to reference, breaking our rather poor way
of detecting something from an error string. So, to be future-proof
to more libgit2 oddities, it might be wise to use strcasestr
in this situation. But this seems a not fully supported variant of
strstr, so leave it at this point.

Signed-off-by: Jan Mulder <jlmulder@xs4all.nl>
2017-07-29 08:30:08 -07:00
Jan Mulder
44e8d302ef Fix small memory leak
Add 2 forgotten free() statements for the temporary used string
buffers.

Signed-off-by: Jan Mulder <jlmulder@xs4all.nl>
2017-07-29 08:30:08 -07:00
Linus Torvalds
5be6fd2f8e Import all pressure sensors from Liquivision logs
The other pressure sensors were disabled on import because we didn't use
to handle multiple sensors well at all.

Now it "JustWorks(tm)".

Signed-off-by: Linus Torvalds <torvalds@linux-foundation.org>
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
2017-07-28 21:50:30 -07:00
Linus Torvalds
92b1c318bd Fix manual pressures for cylinders with no gas switches
"If it hasn't been tested, it doesn't work".

All my testing of the multiple sensor pressures have been with some
reasonably "interesting" dives: they actually *have* sensor pressures.

But that test coverage means that I missed the truly trivial case of
just having manual pressures for a single cylinder.

Because there's only a single cylinder, it doesn't have any cylinder
changes, and because there were no cylinder changes, it never filled in
the use range for that cylinder.

So then it never showed the pressure profile at all.

Duh.

Signed-off-by: Linus Torvalds <torvalds@linux-foundation.org>
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
2017-07-28 21:50:25 -07:00
Linus Torvalds
df1bd0015a Calculate momentary SAC rates with the right gases
The momentary SAC rate got broken by the multiple ressure handling too,
and always used just the first cylinder.

This uses the new "get_gasmix()" helper to see what you're breathing,
and will do the SAC rate over all the cylinders that contain that gas.
So it should now DTRT even for sidemount diving (assuming you had the
same gas in the sidemount cylinders).

NOTE! We could just do the SAC rate over *all* the gases you have
pressures for, and maybe that's the right thing to do.  The ones you are
not breating from shouldn't have their pressure change.  But maybe some
people add their drysuit argon gas to the gas list?

So this may need more work, but it's a step in the right direction.

Signed-off-by: Linus Torvalds <torvalds@linux-foundation.org>
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
2017-07-28 21:50:23 -07:00
Linus Torvalds
defa71256f Use the right gasmix for deco calculations
In commit e1b880f4 "Profile support for multiple concurrent pressure
sensors" I had mindlessly hacked away at some of the sensor lookups from
the plot entries to make it all build, and forgotten about my butchery.

Thankfully Jan and Davide noticed in their multi-cylinder deco dives
that the deco calculations were no longer correct.

This uses the newly introduced "get_gasmix()" helper to look up the
currently breathing gasmix, and fixes the deco calculations.

Reported-and-tested-by: Jan Mulder <jlmulder@xs4all.nl>
Reported-by: Davide DB <dbdavide@gmail.com>
Signed-off-by: Linus Torvalds <torvalds@linux-foundation.org>
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
2017-07-28 21:50:20 -07:00
Linus Torvalds
1e337518b8 Add "get_gasmix()" helper function to iterate over gas changes
We have a few places that used to get the gasmix by looking at the
sensor index in the plot data, which really doesn't work any more.

To make it easier for those users to convert to the new world order,
this adds a "get_gasmix()" function.  The gasmix function takes as its
argument the dive, the dive computer, and the time.

In addition, for good performance (to avoid looping over the event list
over and over and over again) it maintains a pointer to the next gas
switch event, and the previous gas.  Those need to be initialized to
NULL by the caller, so the standard use-case pattern basically looks
like this:

	struct gasmix *gasmix = NULL;
	struct event *ev = NULL;

	loop over samples or plot events in increasing time order: {
		...
		gasmix = get_gasmix(dive, dc, time, &ev, gasmix);
		...
	}

and then you can see what the currently breathing gas is at that time.

If for some reason you need to walk backwards in time, you can just pass
in a NULL gasmix again, which will reset the event iterator (at the cost
of now having to walk all the events again).

Signed-off-by: Linus Torvalds <torvalds@linux-foundation.org>
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
2017-07-28 21:50:15 -07:00
Linus Torvalds
e1b880f444 Profile support for multiple concurrent pressure sensors
This finally handles multiple cylinder pressures, both overlapping and
consecutive, and it seems to work on the nasty cases I've thrown at it.

Want to just track five different cylinders all at once, without any
pesky gas switch events? Sure, you can do that.  It will show five
different gas pressures for your five cylinders, and they will go down
as you breathe down the cylinders.

I obviously don't have any real data for that case, but I do have a test
file with five actual cylinders that all have samples over the whole
course of the dive.  The end result looks messy as hell, but what did
you expect?

HOWEVER.

The only way to do this sanely was

 - actually make the "struct plot_info" have all the cylinder pressures
   (so no "sensor index and pressure" - every cylinder has a pressure for
   every plot info entry)

   This obviously makes the plot_info much bigger. We used to have
   MAX_CYLINDERS be a fairly generous 8, which seems sane. The planning
   code made that 8 be 20. That seems questionable. But whatever.

   The good news is that the plot-info should hopefully get freed, and
   only be allocated one dive at a time, so the fact that it is big and
   nasty shouldn't be a scaling issue, though.

 - the "populate_pressure_information()" function had to be rewritten
   quite a bit. The good news is that it's actually simpler now, although
   I would not go so far as to really call it simple. It's still
   complicated and suble, but now it explicitly just does one cylinder at
   a time.

   It *used* to have this insanely complicated "keep track of the pressure
   ranges for every cylinder at once". I just couldn't stand that model
   and keep my sanity, so it now just tracks one cylinder at a time, and
   doesn't have an array of live data, instead the caller will just call
   it for each cylinder.

 - get rid of some of our hackier stuff, like the code that populates the
   plot_info data code with the currently selected cylinder number, and
   clears out any other pressures. That obviously does *not* work when you
   may not have a single primary cylinder any more.

Now, the above sounds like all good things. Yeah, it mostly is.

BUT.

There's a few big downsides from the above:

 - there's no sane way to do this as a series of small changes.

   The change to make the plot_info take an array of cylinder pressures
   rather than the sensor+pressure model really isn't amenable to "fix up
   one use at a time". When you switch over to the new data structure
   model, you have to switch over to the new way of populating the
   pressure ranges. The two just go hand in hand.

 - Some of our code *depended* on the "sensor+pressure" model. I fixed all
   the ones I could sanely fix. There was one particular case that I just
   couldn't sanely fix, and I didn't care enough about it to do something
   insane.

   So the only _known_ breakage is the "TankItem" profile widget. That's
   the bar at the bottom of the profile that shows which cylinder is in
   use right now. You'd think that would be trivial to fix up, and yes it
   would be - I could just use the regular model of

     firstcyl = explicit_first_cylinder(dive, dc)
     .. then iterate over the gas change events to see the others ..

   but the problem with the "TankItem" widget is that it does its own
   model, and it has thrown away the dive and the dive computer
   information. It just doesn't even know. It only knows what cylinders
   there are, and the plot_info. And it just used to look at the sensor
   number in the plot_info, and be done with that. That number no longer
   exists.

 - I have tested it, and I think the code is better, but hey, it's a
   fairly large patch to some of the more complex code in our code base.
   That "interpolate missing pressure fields" code really isn't pretty. It
   may be prettier, but..

Anyway, without further ado, here's the patch. No sign-off yet, because I
do think people should look and comment. But I think the patch is fine,
and I'll fix anythign that anybody can find, *except* for that TankItem
thing that I will refuse to touch. That class is ugly. It needs to have
access to the actual dive.

Note how it actually does remove more lines than it adds, and that's
despite added comments etc. The code really is simpler, but there may be
cases in there that need more work.

Known missing pieces that don't currently take advantage of concurrent
cylinder pressure data:

 - the momentary SAC rate coloring for dives will need more work

 - dive merging (but we expect to generally normally not merge dive
   computers, which is the main source of sensor data)

 - actually taking advantage of different sensor data from different
   dive computers

But most of all: Testing.  Lots and lots of testing to find all the
corner cases.

Signed-off-by: Linus Torvalds <torvalds@linux-foundation.org>
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
2017-07-27 14:45:58 -07:00
Linus Torvalds
efc5f4d9ab Add support for loading and saving multiple pressure samples
This does both the XML and the git save format, because the changes
really are the same, even if the actual format differs in some details.
See how the two "save_samples()" routines both do the same basic setup,
for example.

This is fairly straightforward, with the possible exception of the odd

     sensor = sample->sensor[0];

default in the git pressure loading code.

That line just means that if we do *not* have an explicit cylinder index
for the pressure reading, we will always end up filling in the new
pressure as the first pressure (because the cylinder index will match the
first sensor slot).

So that makes the "add_sample_pressure()" case always do the same thing it
used to do for the legacy case: fill in the first slot. The actual sensor
index may later change, since the legacy format has a "sensor=X" key value
pair that sets the sensor, but it will also use the first sensor slot,
making it all do exactly what it used to do.

And on the other hand, if we're loading new-style data with cylinder
pressure and sensor index together, we just end up using the new semantics
for add_sample_pressure(), which tries to keep the same slot for the same
sensor, but does the right thing if we already have other pressure values.

The XML code has no such issues at all, since it can't share the cases
anyway, and we need to have different node names for the different sensor
values and cannot just have multiple "pressure" entries. Have I mentioned
how much I despise XML lately?

Signed-off-by: Linus Torvalds <torvalds@linux-foundation.org>
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
2017-07-25 22:05:32 -07:00
Linus Torvalds
c5167f0039 Make sample pressure helper functions available to everybody
We had a "add_sample_pressure()" helper functions that was local to just
the libdivecomputer downloading code, but it really is applicable to
pretty much any code that adds cylinder pressure data to a sample.

Also add another helper: "legacy_format_o2pressures()" which checks the
sample data to see if we can use the legacy format, and returns the o2
pressure sensor to use for that legacy format.

Because both the XML and the git save format will need a way to save the
compatible old-style information, when possible, but save an extended
format for when we have data from multiple concurrent sensors.

Signed-off-by: Linus Torvalds <torvalds@linux-foundation.org>
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
2017-07-25 22:04:56 -07:00
Jan Mulder
fd03621a4b Mobile: honour location service time threshold
Independ of the settings, the threshold to reset the GPS data was
hard coded to 5 minutes. Now, honour the entered (and updated during
a session) time to refresh the GPS data in the location service.

Signed-off-by: Jan Mulder <jlmulder@xs4all.nl>
2017-07-25 22:12:19 +09:00
Linus Torvalds
adb4b66a05 Try to sanely download multiple concurrent cylinder pressures
This tries to sanely handle the case of a dive computer reporting
multiple cylinder pressures concurrently.

NOTE! There are various "interesting" situations that this whole issue
brings up:

 - some dive computers may report more cylinder pressures than we have
   slots for.

   Currently we will drop such pressures on the floor if they come for
   the same sample, but if they end up being spread across multiple
   samples we will end up re-using the slots with different sensor
   indexes.

   That kind of slot re-use may or may not end up confusing other
   subsurface logic - for example, make things believe there was a
   cylidner change event.

 - some dive computers might send only one sample at a time, but switch
   *which* sample they send on a gas switch event.  If they also report
   the correct sensor number, we'll now start reporting that pressure in
   the second slot.

   This should all be fine, and is the RightThing(tm) to do, but is
   different from what we used to do when we only ever used a single
   slot.

 - When people actually use multiple sensors, our old save format will
   start to need fixing.  Right now our save format comes from the CCR
   model where the second sensor was always the Oxygen sensor.

   We save that pressure fine (except we save it as "o2pressure" - just
   an odd historical naming artifact), but we do *not* save the actual
   sensor index, because in our traditional format that was always
   implicit in the data ("it's the oxygen cylinder").

so while this code hopefully makes our libdivecomputer download do the
right thing, there *will* be further fallout from having multiple
cylinder pressure sensors.  We're not done yet.

Signed-off-by: Linus Torvalds <torvalds@linux-foundation.org>
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
2017-07-25 06:11:10 -07:00
Miika Turkia
1fe22a28ed CCR is now detected from the log data
Signed-off-by: Miika Turkia <miika.turkia@gmail.com>
2017-07-24 13:08:04 +09:00
Miika Turkia
685c59214d Map Divinglog's visibility to our stars
good (1) = 5
medium (2) = 3
bad (3) = 1

There seems also to be 0 used in the log, even though it is not
mentioned in the valid selections. This is not giving any stars for this
option...

Signed-off-by: Miika Turkia <miika.turkia@gmail.com>
2017-07-24 13:08:04 +09:00
Miika Turkia
a7231be9a0 Detect CCR/PSCR from Divinglog import
Signed-off-by: Miika Turkia <miika.turkia@gmail.com>
2017-07-24 13:08:04 +09:00
Miika Turkia
0e9e1b6043 Fix CCR detection on Divinglog import
Note that I have not been able to do a positive test for this due to
lack of CCR sample data. But at least OC dives are now categorized
correctly.

Signed-off-by: Miika Turkia <miika.turkia@gmail.com>
2017-07-24 10:03:07 +09:00
Miika Turkia
27bb76e834 Add visibility support to Divinglog import
Signed-off-by: Miika Turkia <miika.turkia@gmail.com>
2017-07-24 10:03:07 +09:00
Dirk Hohndel
587882c88b QML UI: remember the last dive computer
We already have the infrastructure to do so, all we needed to
do was hook it all up.

Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
2017-07-22 16:15:00 -07:00
Linus Torvalds
92ecbc8c83 parse-xml: use the right dc for filling in extra data
"cur_dc" may be NULL when the XML source isn't a subsurface XML file,
and xml parsing is supposed to use "get_dc()" to pick a dive computer
when the nesting of the XML may not be proper.

Now, XML sources that don't have the proper dive computer nesting
markers generally also do not end up having the extra-data string
information, but one example of this is the simple XML that the
libdivecomputer 'dctool' program generates.

Signed-off-by: Linus Torvalds <torvalds@linux-foundation.org>
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
2017-07-22 10:38:11 -07:00
Linus Torvalds
b9f52d0aff Gas usage statistics: don't require gas switch events
Our "get_has_used()" helper only filled in gas usage for cylinders that
had a gas change event associated with them.  That works really badly
for things like CCR, but also simply for cases where the dive computer
wasn't necessarily explicitly notified about usage, like sidemount
diving etc.

Just remove the logic.  If some use ends up particularly wanting to
ignore some cylinder, they can always do it in the caller instead.

Signed-off-by: Linus Torvalds <torvalds@linux-foundation.org>
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
2017-07-22 10:38:00 -07:00
Linus Torvalds
f2a6a76b3e Fix up o2 pressure sensor handling at load time
Because of how we traditionally did things, the "o2pressure" parsing
depends on implicitly setting the sensor index to the last cylinder that
was marked as being used for oxygen.

We also always defaulted the primary sensor (which is used for the
diluent tank for CCR) to cylinder 0, but that doesn't work when the
oxygen tank is cylinder 0.

This gets that right at file loading time, and unifies the xml and git
sample parsing to make them match. The new defaults are:

 - unless anything else is explicitly specified, the primary sensor is
   associated with the first tank, and the secondary sensor is
   associated with the second tank

 - if we're a CCR dive, and have an explicit oxygen tank, we associate
   the secondary sensor with that oxygen cylinder.  The primary sensor
   will be switched over to the second cylinder if the oxygen cylinder
   is the first one.

   This may sound backwards, but matches our traditional behavior where
   the O2 pressure was the secondary pressure.

This is definitely not pretty, but it gets our historical files working
right, and is at least reasonably sensible.

Signed-off-by: Linus Torvalds <torvalds@linux-foundation.org>
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
2017-07-21 16:34:33 -07:00
Linus Torvalds
ea31800f61 git save format: don't save redundant sample information
When we load sample data from a git save-file, we always default to
using the state from the previous sample (except for the special case of
cylinder pressure where an empty value does not mean "same", but
"interpolate", see core/load-git.c: new_sample()).

But the corollary to that is that it's always redundant to save sample
data that hasn't changed since the previous sample.

For some reason, the rbt, bearing and heartrate sample data didn't
follow that rule, and instead saved with lots of extra reduncancy.

(The alternative would be to clear those samples at load time, and make
them act like the pressure data, but it would appear that all these
three values may as well just have the normal "if no change, don't save
them" semantics).

Signed-off-by: Linus Torvalds <torvalds@linux-foundation.org>
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
2017-07-21 16:33:45 -07:00
Linus Torvalds
1e38d9239a Start cleaning up sensor indexing for multiple sensors
This is a very timid start at making us actually use multiple sensors
without the magical special case for just CCR oxygen tracking.

It mainly does:

 - turn the "sample->sensor" index into an array of two indexes, to
   match the pressures themselves.

 - get rid of dive->{oxygen_cylinder_index,diluent_cylinder_index},
   since a CCR dive should now simply set the sample->sensor[] indices
   correctly instead.

 - in a couple of places, start actually looping over the sensors rather
   than special-case the O2 case (although often the small "loops" are
   just unrolled, since it's just two cases.

but in many cases we still end up only covering the zero sensor case,
because the CCR O2 sensor code coverage was fairly limited.

It's entirely possible (even likely) that this migth break some existing
case: it tries to be a fairly direct ("stupid") translation of the old
code, but unlike the preparatory patch this does actually does change
some semantics.

For example, right now the git loader code assumes that if the git save
data contains a o2pressure entry, it just hardcodes the O2 sensor index
to 1.

In fact, one issue is going to simply be that our file formats do not
have that multiple sensor format, but instead had very clearly encoded
things as being the CCR O2 pressure sensor.

But this is hopefully close to usable, and I will need feedback (and
maybe test cases) from people who have existing CCR dives with pressure
data.

Signed-off-by: Linus Torvalds <torvalds@linux-foundation.org>
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
2017-07-21 16:33:19 -07:00
Linus Torvalds
11a0c0cc70 Unify sample pressure and o2pressure as pressure[2] array
We currently carry two pressures around for all the samples and plot
info, but the second pressure is reserved for CCR dives as the O2
cylinder pressure.

That's kind of annoying when we *could* use it for regular sidemount
dives as the secondary pressure.

So start prepping for that instead: don't make it "pressure" and
"o2pressure", make it just be an array of two pressure values.

NOTE! This is purely mindless prepwork.  It literally just does a
search-and-replace, keeping the exact same semantics, so "pressure[1]"
is still just O2 pressure.

But at some future date, we can now start using it for a second sensor
value for sidemount instead.

Signed-off-by: Linus Torvalds <torvalds@linux-foundation.org>
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
2017-07-20 17:32:54 -07:00
Dirk Hohndel
94d8abd1a2 Correct list of Shearwater BLE dive computers
Some Petrel 2 computers are dual stack. We need to list the Petrel here as well
since the Petrel 2 actually identifies itself via BT/BLE as Petrel and we can't
tell them appart until after we started a download.

Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
2017-07-19 06:21:23 -07:00