This is based on the great work done by Søren Reinke's on his MKVI Logfile
Analyzer.
Signed-off-by: Anton Lundin <glance@acc.umu.se>
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
This is based on the great work done by Søren Reinke's on his MKVI Logfile
Analyzer.
Signed-off-by: Anton Lundin <glance@acc.umu.se>
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
This is based on the great work done by Søren Reinke's on his MKVI Logfile
Analyzer.
Signed-off-by: Anton Lundin <glance@acc.umu.se>
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
This is based on the great work done by Søren Reinke's on his MKVI Logfile
Analyzer.
Signed-off-by: Anton Lundin <glance@acc.umu.se>
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
This code sets up the UI that will allow the user to adjust tank pressures
at a gaschange event. The actual changing of the pressure is not
implemented, yet, so this is disabled until someone finds time to do so.
The scenario is this: a tec diver or sidemount diver without pressure
sensors on at least one of their tanks still wants to reasonably
accurately track gas consumption during a dive. The diver takes notes of
the pressures at every tank switch (I find that odd, but apparently some
cave divers indeed do that as they switch back and forth between different
gases) and then wants to adjust the pressures in Subsurface to match those
written down.
One difficulty here is that the first and last pressure of a tank with no
sensor data is still considered "sensor pressure" - this is basically an
implementation detail in the code that is used to do the pressure
interpolation to have constant-SAC pressure plots for tanks without
sensors. So when we check if there is indeed no pressure data available at
the gas change, we can't just work with the interpolated pressure - if
this is the first (or last) time the tank was used, that pressure may be
marked as sensor pressure.
What's missing is the UI to enter the desired new pressure plus the black
magic that actually inserts this into the dive in a way that doesn't break
the assumptions in the rest of the code. I'm running out of time to do
that but wanted to preserve this code so someone can continue this later.
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
We had the variable. As a pointer. Which we used memset to clear. Ouch -
that smells like some bad cut and paste.
With this change the object keeps the corresponding plotInfo around (just
like some others do) and can use it later. I suspect this code could use
some larger cleanup, but it's a bit too late for this in the development
cycle, I guess. I'm sure I'll regret this in the future...
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
In the context menu of the profile it makes no sense to offer the ability
to switch gases unless there is a gas to switch to.
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
Includes the dive list filters and modifications on tissues graph.
Corrects a typpo.
Signed-off-by: Salvador Cuñat <salvador.cunat@gmail.com>
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
Added comment about meaning of o2pressure in struct plot_info.
Turned some pressures from double (in bar) to pressure_t (in mbar)
[Dirk Hohndel: picked parts of this patch and dropped others]
Signed-off-by: Robert C. Helling <helling@atdotde.de>
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
The only place where I'm not sure if there are unintended sideeffects of
changing over to the new domain is QCoreApplication::setOrganizationDomain
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
In commit 0d7c192e6e ("For CCR dives, the diluent cylinder is the
current cylinder") a few things got broken. This tries to undo those
changes and adds expanded XML output.
1) Calculate correct partial pressure of oxygen to be plotted on
dive profile, taking into account the oxygen sensor data.
Currently, erroneously, OC PO2 values are shown, due to an
erroneous calling parameter to fill_pressures().
2) Read start and end cylinder pressured correctly. some wrong
assignments were done in file.c. This is now corrected and the correct
cylinder pressures are shown in the equipment tab.
3) Write correct cylinder pressures to XML. Currently the data for
the two cylinders are written to XML the wrong way round
(diluent pressures = oxygen and vice versa).
4) Expand XML output:
a) Write oxygen sensor data to XML
b) Write no_of_02sensors to XML
Signed-off-by: willem ferguson <willemferguson@zoology.up.ac.za>
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
In commit d5d7fdc9af ("For CCR dives, show plot for diluent and O2
cylinder pressures") we end up dereferencing current before it is first
initialized. Bad.
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
Qt by default uses a rather simplistic text heuristic to figure out if a
menu entry is one of the special ones that need to be moved into the
application menu (About, Preferences, Quit - but for Preferences anything
that matches settings, options, config is used as well).
This patch tells Qt to keep its hands off the the DC configuration entry
in the menu.
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
RulerNodeItem2::recalculate() does something which is
apparently not a good idea in combination with
RulerNodeItem2::mouseMoveEvent().
Each time the mouse moves, setPos() is called. Then in
recalculate() the x() value is checked and if less than 0
it's changed to x = 0 (setPos(0, y());).
This last call (setPos(0, y());)
however does not work and the value remains less than zero
leaving one of the ruler points outside of the graph.
To solve the issue we add a silly explicit check if x() < 0
before calling setPos() in RulerNodeItem2::mouseMoveEvent().
The 'x() > timeAxis->posAtValue(data->sec)' strangely works
on the other hand.
Signed-off-by: Lubomir I. Ivanov <neolit123@gmail.com>
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
Extend the tooltips to be shown both on the labels and the values and add
tooltips for all min/avg/max elements.
To avoid confusion when only one dive is selected, no longer show min SAC
or max SAC or min duration or max duration.
Fixes#694
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
Remove the unused upper widget, set a somewhat random but at least more
reasonable default size and finally support Ctrl-W and Ctrl-Q shortcuts.
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
Also fixes a bug in the diluent pressure interpolation
Signed-off-by: Robert C. Helling <helling@atdotde.de>
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
Covers CCR APD and Poseidon divelogs and importing. Already changed
by the time of writing this commit, at least twice.
Signed-off-by: Salvador Cuñat <salvador.cunat@gmail.com>
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
Somehow I forgot to submit this back in October.
Includes the gases pressures bar graph.
Signed-off-by: Salvador Cuñat <salvador.cunat@gmail.com>
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
Change the meaning that _the_ cylinder (as we treat it in OC dives) is the
diluent cylinder (rather than the O2 cylinder). This eliminates special
cases. Now, for CCR, we have to handle the O2 cylinder in addition
(rather than the diluent in addition).
Signed-off-by: Robert C. Helling <helling@atdotde.de>
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
Slowly trying to track down all spots where we copy string pointers
instead of string data. And making sure that we free those pointers before
overwriting them.
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
Maybe it would be better to just copy the whole structure and then clear
the things we don't want to copy? This seems fragile.
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
We copied the string pointers instead of copying the strings. Once those
got freed, things went downhill.
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
Few smaller changes to text dealing with tissue pressures graph
Signed-off-by: willem ferguson <willemferguson@zoology.up.ac.za>
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
Random constants are bad. Let's use the indices that we already calculated
(and true and false if we mean boolean values).
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
--047d7b8737f87ede8e050803e6b2
Content-Type: text/plain; charset=UTF-8
<div dir="ltr"><br></div>
From 3db4a422485374801ca2f6233ec23b8671a8656d Mon Sep 17 00:00:00 2001
From: Tomaz Canabrava <tomaz.canabrava@intel.com>
Date: Sun, 16 Nov 2014 23:22:58 -0200
Subject: [PATCH] fix 727 - position correctly the popup.
When the user entered a tag and that made the message box display
the popup with the possible choices was still in the old position
hidding the line edit.
Signed-off-by: Tomaz Canabrava <tomaz.canabrava@intel.com>
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
This is an anonymized version of a real dive. With the latest changes the
SAC calculations now make "mostly sense".
What's clearly still broken is the tank pressure graph.
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
This patch is bigger than necessary because I also renamed the
get_cylinder_use() function to the much more accurate
get_cylinder_idx_by_use().
If we have no gas changes (except for a possible explicit first gas),
(which in the CCR case also means no bailout), this code will give you
correct per cylinder depth and duration for oxygen and diluent and
therefore create more reasonable gas consumption data for CCR dives.
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>