Commit graph

275 commits

Author SHA1 Message Date
Berthold Stoeger
f687e51d4b core: don't consider dives with many samples as manually added
This causes UI confusion. Notably we go into edit mode and
reduce the number of samples, leading to loss of information.

If someone really manually adds a dive with more than 50
samples, they should still be able to explicitly open the
dive in the planner.

Signed-off-by: Berthold Stoeger <bstoeger@mail.tuwien.ac.at>
2022-10-21 16:51:57 -07:00
Linus Torvalds
02f158b0c2 Fix the dc sensor index fixup
fixup_dc_sample_sensors() would make sure that any pressure sensor
indexes were in range of the cylinders by just clearing the pressure
data if the sensor index was larger than the number of cylinders in the
dive.

That certainly makes the sensor index data consistent, but at the cost
of just dropping the sensor data entirely.

Dirk had some cases of odd sensor data (probably because of an older
version of subsurface, but possibly due to removing cylinders manually
or because of oddities with the downloader for the Atomic Aquatics
Cobalt dive computer he used), and when re-saving the dive, the pressure
data would magically just get removed due to this.

So rewrite the sensor data fixup to strive very hard to avoid throwing
pressure sensor data away.  The simplest way to do that is to just add
the required number of cylinders, and then people can fix up their dives
manually by remapping the sensor data.

This whole "we clear the pressure data" was at least partly hidden by
two things:

 (1) in the git save format, we don't rewrite dives unless you've
     changed the dive some way, so old dives stay around with old data
     in the save until explicitly changed.

 (2) if you had multiple dive computers, and one dive computer does not
     have any pressure data but another one does, our profile will use
     that "other" dive computer pressure data (because often times you
     might have only one dive computer that is air integrated, but you
     still want to see the tank pressure when you look at other dive
     computers - or you have one dive computer give pressure data for
     your deco bottle, and another for your travel gas etc).

So those two facts hid the reality that we had actually cleared the tank
sensor data for Dirk's dive with the Atomic Aquatics dive computer,
because we'd still see pressure data in the profile, and the git data
would still be the old one.

Until Dirk renumbered his dives, and the data was rewritten.

Signed-off-by: Linus Torvalds <torvalds@linux-foundation.org>
2022-09-20 09:49:57 -07:00
Linus Torvalds
3446dd5125 fix up sample sensor indexes before fixing up cylinder pressures
The cylinder pressure fixup depends on the sample sensors indexes having
been fixed.

Signed-off-by: Linus Torvalds <torvalds@linux-foundation.org>
2022-09-12 16:58:59 -04:00
Berthold Stoeger
acd385048a Prefer real data over planned
When a dive has both real dive computers as well as at
least a planned version (which is just another dive
computer with a special name), only use the data from
real dive computers for aggregate values like maxdepth,
dive time, average depth etc in order not to have
imagined data on the dive list, statistics etc.

Macro-magic-provided-by: Dirk Hohndel <dirk@hohndel.org>
Signed-off-by: Robert C. Helling <helling@atdotde.de>
2022-08-25 13:38:12 -07:00
Dirk Hohndel
19b221d203 core: add missing properties to the dive merge
In a sign how few people use these additional properties AND use multiple
dive computers, this took a couple of years to get noticed... but yes, we
do need to merge those properties as well.

Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
2022-06-08 13:29:37 -07:00
Linus Torvalds
bdeeba4a67 core: fix detection of used cylinders
The cylinder_with_sensor_sample() function only tests "do we have a mapping to
this cylinder for this sample". It also needs to test if there are any tank
pressure readings for that cylinder.

Signed-off-by: Linus Torvalds <torvalds@linux-foundation.org>
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
2022-04-28 12:30:10 -07:00
Dirk Hohndel
8d9730f74f core: avoid crash when merging dive with no cylinders
Arguably every dive should at least have one cylinder, but an imported
dive from divelogs.de might end up without one. Sadly, that breaks
assumptions that we make in the cylinder remapping.

To work around it, force at least on cylinder to be assumed in the merge
code.

Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
2022-04-24 08:00:36 -07:00
Berthold Stoeger
12406786f1 core: pass dc-number to update_event_name()
The dive was passed as an argument to update_event_name(), but
the divecomputer was derived from the global dc_number variable.
That makes no sense. Therefore, pass the dc_number as argument
and update the only caller (smtk-import).

Signed-off-by: Berthold Stoeger <bstoeger@mail.tuwien.ac.at>
2022-03-13 15:07:33 -07:00
Berthold Stoeger
0c4be83b31 core: split proper divecomputer in split_divecomputer()
split_divecomputer() is passed a dive and a divecomputer number.
However, it accesses the currently visible dc!

This would be a nasty bug if it werent for the fact that it is
called when placing an undo command and there it is passed the
current dive and divecomputer anyway.

Nevertheless, fix this.

Signed-off-by: Berthold Stoeger <bstoeger@mail.tuwien.ac.at>
2022-03-13 15:07:33 -07:00
Berthold Stoeger
9e0712d5dc core: replace dive master by dive guide
In general, replace "dive master" by "dive guide".

However, do not change written dive logs for now. On reading,
accept both versions.

Signed-off-by: Berthold Stoeger <bstoeger@mail.tuwien.ac.at>
2022-02-15 09:35:43 -08:00
Berthold Stoeger
0e9eee0a7f core: return floating point from to_PSI() functions
Dive data are stored internally using integral types using
appropriately fine units (mm, mbar, mkelvin, etc.). These
are converted with functions defined in units.h for display
(m, bar, C, etc.). Usually floating points are returned by
these functions, to retain the necessary precision. There
is one exception: the to_PSI() and mbar_to_PSI() functions.

For consistency, make these functions likewise return floats.
This will be needed for the rework of the profile-axes.
The plan is to use the conversion functions to make the
axes aware of the displayed values. This in turn will be
necessary to place the ticks at sensible distances. However,
the conversions need to be precise, which is not the
case for the current to_PSI() functions.

Signed-off-by: Berthold Stoeger <bstoeger@mail.tuwien.ac.at>
2021-12-17 11:54:23 -08:00
Robert C. Helling
9fd531dcc5 Round gas depth properly
The D in MOD, EAD, END, and EADD stands for "depth" and
as such these should be mm in int rather than double.

The intermediate fn2 and fhe2, however, as intermediate
value should not be rounded to an integer.

The upshot of this is a litle more numerical stability.
It should lead to more stable values in TestProfile
when run on architectures with different floating
point precision.

Signed-off-by: Robert C. Helling <helling@atdotde.de>
2021-12-06 22:29:04 +01:00
Berthold Stoeger
540e4437d5 cleanup: fix conversion warning
Fix a pair of warnings, which annoyed me for a long time:
For some reasons prefs.bottompo2 is an integer (mbar)
whereas prefs.modpO2 is a float (bar). This results
in mixed integer/floating point arithmetics when
conditionally using either of them. And ultimately
a warning, when storing a mbar value as an integer.
Fix this by an explicit cast to int after converting
modpO2 to mbar.

Signed-off-by: Berthold Stoeger <bstoeger@mail.tuwien.ac.at>
2021-10-16 15:32:56 -07:00
Berthold Stoeger
d9c77a27da core: properly clear pressure data of invalid sensors
When we found an invalid sensor (referring to a non
existing cylinder) in fixup_dive() the sensor-id was
set to NO_SENSOR.

This led to invalid XML files, because the code decides
to switch into legacy mode. However, there are two
pressure readings, which is invalid in legacy mode.

Therefore, also clear the pressure data.

Signed-off-by: Berthold Stoeger <bstoeger@mail.tuwien.ac.at>
2021-09-22 09:11:00 -07:00
Berthold Stoeger
28fe6a7b38 core: add a function to test for sensors of a given cylinder
We want to prevent the user from accidentally deleting a
cylinder with sensor readings. Therefore, we need such a
function.

Signed-off-by: Berthold Stoeger <bstoeger@mail.tuwien.ac.at>
2021-09-03 13:35:28 -07:00
Dirk Hohndel
75fdb8676b core: add downloaded GPS to existing dive site
If we download a first dive computer and add a dive site to the dive (by
setting a location name for example), and then download from another
dive computer that provides us with GPS data, we should keep the
existing dive site information, but add the GPS data from the freshly
downloaded dive computer.

Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
2021-08-15 09:31:17 -07:00
Berthold Stoeger
846e1ba53e core: always create a fake profile if there are no samples
Before making the cylinder-table dynamic, dives always
had at least one cylinger. When such a dive is displayed,
the TabDiveInformation class calls per_cylinder_mean_depth().
If there are no samples, this function generates a "fake
profile" with fake_dc(). Thus, effectively dives always
had samples once the user was displaying them.

When the cylinder-table was made dynamic, dives without
cylinders were supported. This can notably happen, when
importing from CSV (this could actually be a bug).
per_cylinder_mean_depth() exits early in that case and
doesn't create a fake profile. This lead to crashes
of the profile-widget, which were fixed in 6b2e56e513.
Non-sample dives were now shown with the Subsurface-logo.

To restore the previous behavior, genarate a fake profile
for sample-less dives in fixup_dive(), which is called
anytime  a dive is loaded or imported. This seems to
have been the intention anyway and this worked only
"by chance". This will make a few fake_dc() calls obsolete,
but so be it.

Since fake profiles are now generated on loading,
the parse-tests need to be fixed to account for that.

Signed-off-by: Berthold Stoeger <bstoeger@mail.tuwien.ac.at>
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
2021-07-23 11:30:17 -07:00
Berthold Stoeger
63e1516579 core: recalculate CNS values on merge
When merging two dives, the higher CNS value was taken. This could
result in inconsistent CNS values if two dives were merged where
one dive's CNS was calculated from a "fake profile", i.e. a dive
without dive-computer profile. In that case, the most conservative
value (all time spent at the bottom) was assumed. The merged dive
then consisted of the dive-computer profile and the conservative
CNS estimate.

This is fixed by setting the CNS value to "0" after merging,
which means "unknown". The correct value will then be recalculated
in "fixup_dive" from the actual sample data.

Signed-off-by: Berthold Stoeger <bstoeger@mail.tuwien.ac.at>
2021-07-23 11:30:17 -07:00
Berthold Stoeger
82f967ddb3 core: sanitize pressure-sensor cylinder ids in fixup_dive()
The code will happily perform out-of-bound accesses if
pressure-sensors refer to non-existing cylinders. Therefore,
sanitize these values in fixup_dive(), which is called
everytime a dive is loaded or imported.

Signed-off-by: Berthold Stoeger <bstoeger@mail.tuwien.ac.at>
2021-07-19 10:13:51 -07:00
Berthold Stoeger
7e11a35371 core: add a special NO_SENSOR value for sample::sensor
The sensor member of sample refers to a cylinder from which
the pressure was read. However, some dives don't even have
a cylinder. Therefore, introduce a special NO_SENSOR value
for these dives. Since the cylinder is given as a uint8_t,
0xff seems to be a sensible choice.

Signed-off-by: Berthold Stoeger <bstoeger@mail.tuwien.ac.at>
2021-07-19 10:13:51 -07:00
mikeller
2d734c529b desktop: Add the capability to copy / paste dive number and date / time.
This is adding the capability to select 'Dive number' and 'Date / Time'
in the 'Copy dive components' dialog, and then copy them into the
clipboard.
When using 'Paste dive components, these values will then be pasted into
the selected dive(s).
This is intended to help with workflows that import dive information
from two different sources, like general information from another
logging program, and CCR ppO2 sensor readings from a unit log, and then
stitch them together into one cohesive entry with all data per dive.
Copied data is also output into formatted text when pasting the
clipboard outside of the application:

```
Dive number: 401
Date / time: Sun 2 May 2021 12:00 AM
```

No translations have been added as of now - I could not find any
information on how strings are translated for this project.

Signed-off-by: Michael Keller <github@ike.ch>
2021-05-19 15:15:34 -07:00
Berthold Stoeger
cd32c280ae undo: remove invalidate_dive_cache() call from make_first_dc()
The make_first_dc() function clones a dive with a certain dive
computer moved to the front. This is used by the
MoveDiveComputerToFront undo command.

make_first_dc() calls invalidate_dive(). However, the undo
command does that by itself on every undo/redo. Thus,
remove the call in make_first_dc().

Aside from consistency, the goal is to move invalidate_dive()
to command/* so that we can be more aggressive about the whole
topic: Store only "const dive *" pointers and thus force any
writing access to explicitly invalidate the dive cache.

Signed-off-by: Berthold Stoeger <bstoeger@mail.tuwien.ac.at>
2021-01-11 08:42:17 -08:00
Berthold Stoeger
be9f9efb0e profile: pass dive to EventItem
Don't access the global displayed_dive variable in an effort
to make the profile reentrant.

Note that this still accesses the global dc_number variable,
which will likely have to be removed.

Signed-off-by: Berthold Stoeger <bstoeger@mail.tuwien.ac.at>
2021-01-10 15:57:39 -08:00
Berthold Stoeger
18acb85a01 cleanup: don't save PASCAL pressure units to git
The way I understand, the PASCAL pressure unit is used to parse
obscure dive logs. However, there is no support in the UI for
using Pa as pressure unit. Therefore remove reading / writing
this unit to git divelogs.

Signed-off-by: Berthold Stoeger <bstoeger@mail.tuwien.ac.at>
2021-01-02 10:26:29 -08:00
Berthold Stoeger
b36178a00a cylindermodel: remove in_planner() use
in_planner() is problematic, since it is uses desktop-only
application state. Since the cylinder-model already has
an appropriate inPlanner flag, use this instead.

Signed-off-by: Berthold Stoeger <bstoeger@mail.tuwien.ac.at>
2020-11-24 10:54:10 +01:00
Robert C. Helling
10bedf02d0 Gracefully handle infinite MND for oxygen
When breathing pure oxygen and considering it not
narcotic, there is not maximal narcotic depth and
the formula divides by zero. So better, handle this
case separately.

Fixes #3080

Signed-off-by: Robert C. Helling <helling@atdotde.de>
2020-11-13 11:10:48 -08:00
Berthold Stoeger
f728923c79 cleanup: move interpolate inline function to its own header file
This is not really related to struct dive, so let's move it.

Signed-off-by: Berthold Stoeger <bstoeger@mail.tuwien.ac.at>
2020-10-25 13:59:52 -07:00
Berthold Stoeger
0e196310f9 cleanup: split out divecomputer functions from dive.c
Since dive.c is so huge, split out divecomputer-related functions
into divecomputer.[c|h], sample.[c|h] and extradata.[c|h].

This does not give huge compile time improvements, since
struct dive contains a struct divecomputer and therefore
dive.h has to include divecomputer.h. However, it make things
distinctly more clear.

Signed-off-by: Berthold Stoeger <bstoeger@mail.tuwien.ac.at>
2020-10-25 13:59:52 -07:00
Berthold Stoeger
4aa571d5a0 cleanup: remove get_times() functions
The function
1) was misnamed: it determined the time of the first selcted dive.
2) had only one caller.
3) would crash if there was no selected dive.

Let's just fold the functionality into the caller. It's a one-liner
anyway.

Signed-off-by: Berthold Stoeger <bstoeger@mail.tuwien.ac.at>
2020-10-25 13:59:52 -07:00
Berthold Stoeger
464dd93fe8 cleanup: move fill_pressures from dive.c to gas.c
This function does not access a dive structure.

Signed-off-by: Berthold Stoeger <bstoeger@mail.tuwien.ac.at>
2020-10-25 13:59:52 -07:00
Berthold Stoeger
8212acc992 cleanup: break out event-related code into event.[c|h]
In an effort to reduce the size of dive.h and dive.c, break out
the event related functions. Moreover event-names were handled
by the profile-code, collect that also in the new source files.

Signed-off-by: Berthold Stoeger <bstoeger@mail.tuwien.ac.at>
2020-10-25 13:59:52 -07:00
Berthold Stoeger
b7a586a5b4 core: remove create_device_node() from fixup_dive()
The device nodes are created for all DCs, when importing the
dives. There is no point in creating only the device node for
the first DC in fixup_dive().

Signed-off-by: Berthold Stoeger <bstoeger@mail.tuwien.ac.at>
2020-10-24 09:51:37 -07:00
Berthold Stoeger
8549f24c91 core: add device_table parameter to device table functions
Instead of accessing the global device table directly, add a parameter
to all device-table accessing functions. This makes all places in
the code that access the global device table grep-able, which is
necessary to include the device-table code in the undo system.

Signed-off-by: Berthold Stoeger <bstoeger@mail.tuwien.ac.at>
2020-10-16 14:26:37 -07:00
Berthold Stoeger
b3f5473b66 core: don't merge sample-derived pressures in merge_one_cylinder()
These will be recalculated from the pressures in fixup_dive()
anyway.

Suggested-by: Linus Torvalds <torvalds@linux-foundation.org>
Signed-off-by: Berthold Stoeger <bstoeger@mail.tuwien.ac.at>
2020-10-05 12:59:02 -07:00
Berthold Stoeger
6729428b6a core: improve merging of cylinders pressures
When merging cylinders pressures derived from samples were taken
as maximum of the start and minimum of the end pressure, which
makes sense, since we believe that this is the same cylinder.

However, for manually entered pressures, this was not done.

Moreover, when one dive had manual pressures and the other only
pressure from samples, the manual pressure was taken. However,
that could have been the wrong one, for example if the end
pressure was manually set for the cylinder of the first part of
the dive, but not the last.

Therefore, improve merging of manuall set pressures in two ways:
1) use maximum/minimum for start/end pressure
2) if the pressure of one cylinder was manually set, but not for
   the other, complete with the sample pressure (if that exists).

Fixes #2884.

Signed-off-by: Berthold Stoeger <bstoeger@mail.tuwien.ac.at>
2020-10-05 12:59:02 -07:00
Berthold Stoeger
23da23a534 core: add N2 and general gas component accessors
There were helper functions to access O2 and He component fractions.
Add another one for N2. Indeed, this can be used in three cases, where
N2 was deduced indirectly.

Moreover, add a general accessor with a gas_component argument.
This will be used by the filter code to filter for gas components.

Signed-off-by: Berthold Stoeger <bstoeger@mail.tuwien.ac.at>
2020-10-03 10:29:15 -07:00
Robert C. Helling
efdc875aa3 Use correct pO2 when computing MOD in equipment tab
The cylinder model is used both in the planner and the
equipment tab. We have three preferences for the pO2 that
is used to compute MOD: In the planner, there is one for
the bottom part of the dive and another one for deco.
Those are set in the planenr UI. There is another value,
controlled in the Tec Prefernces. That one should be
used in the equipment tab rather than the one from
the planner.

Fixes #2984

Signed-off-by: Robert C. Helling <helling@atdotde.de>
2020-09-29 15:46:55 -07:00
Berthold Stoeger
bee2dea7cc cleanup: remove invalidate_dive_cache() call in clone_delete_divecomputer()
The function was called on a freshly copied dive, which has its git cache
invalidated automatically in copy_dive().

Signed-off-by: Berthold Stoeger <bstoeger@mail.tuwien.ac.at>
2020-09-08 17:20:09 -07:00
Berthold Stoeger
0a747608b1 cleanup: remove dead code from delete_divecomputer()
delete_divecomputer had legacy code, which
1) invalidated the git dive cache
2) made sure that the dive computer was not displayed anymore

However, both callers called on a freshly copied dive, which
has its dive cache invalidated in copy_dive() and can't be
the currently displayed dive. Therefore, this code is dead
code and can be removed.

Signed-off-by: Berthold Stoeger <bstoeger@mail.tuwien.ac.at>
2020-09-08 17:20:09 -07:00
Berthold Stoeger
048cdcaa31 cleanup: remove count_divecomputers() function
There is a number_of_computers() function which does
the same thing with two exceptions:
1) checks for null-dive
2) returns an unsigned int

Replace calls to count_divecomputers() by calls to number_of_computers().
In one case, the return type makes a different - add a cast to int there.
Ultimately, we should probably change the dc_number to signed int
throughout the code.

Signed-off-by: Berthold Stoeger <bstoeger@mail.tuwien.ac.at>
2020-09-08 17:20:09 -07:00
Berthold Stoeger
e5923a105a cleanup: use taxonomy_get_country() in get_dive_country()
get_dive_country() was essentially a reimplementation of taxonomy_get_country().
Let's just use the already existing function.

Signed-off-by: Berthold Stoeger <bstoeger@mail.tuwien.ac.at>
2020-09-06 12:59:54 -07:00
Robert C. Helling
b1a1dc3639 Function for "gravity conversion"
This adds a common macro to convert salinity (which is
given as a density in terms of g per 10l) to a specific
weight with units of mbar / mm = bar / m that is used
to translate between pressures and depths.

The weired factor of 10 (from the unusual unit of salinity)
is included in the macro. It is there for historical reasons,
as it goes back to 05b55542c8 from 2012 where it was introduced
in code for downloading from Uemis dive computers.

Now, salinity appears in too many places to easily remove
this unconventional factor of 10 everywhere without breaking
to many things (including various dive computer downloads).

Signed-off-by: Robert C. Helling <helling@atdotde.de>
2020-09-06 12:50:59 -07:00
Robert C. Helling
7e82205e9b Planner: Properly initialize salinity
When the dive has no explicity salinity, our conversion
between pressure and depth assumed salt water. Make this
explicity by using the corresponding macro.

When the planner starts and no salinity is set explicity,
set the water type chooser to salt water to reflect
our default assumption.

Signed-off-by: Robert C. Helling <helling@atdotde.de>
2020-09-02 09:43:38 -07:00
Linus Torvalds
77a11400a1 Fix event merging when merging dives
The merge_events() function was subtly and not-so-subtly broken in a
couple of ways:

 - in commit 8c2383b49 ("Undo: don't modify source-dives on merge"), we
   stopped walking the event list after we merged the first event from a
   dive when the other dive computer had run out of events.

   In particular, this meant that when merging consecutive dives, the
   second dive only had the first event copied over to the merged dive.

   This happened because the original code just moved the whole old list
   over when there was nothing left from the other dive, so the old code
   didn't need to iterate over the event list. The new code didn't
   realize that the pointer movement used to copy the whole rest of the
   list, and also stopped iterating.

   In all fairness, the new code did get the time offset right, which
   the old code didn't. So this was always buggy.

 - similarly, the "avoid redundant gas changes" case was not handled for
   the "we ran out of events for the other dive computer" case.

This fixes both issues.

Cc: Berthold Stoeger <bstoeger@mail.tuwien.ac.at>
Signed-off-by: Linus Torvalds <torvalds@linux-foundation.org>
2020-08-15 09:46:19 -07:00
Robert C. Helling
912e1faaf2 Make MND display depend on O2 narcotic preference
A while ago, we introduced a preference whether O2 should
be considered narcotic. We used this when computing
best mix or when entering the He content via MND. But
we forgot to make the displayed MND depend on this
preference. This patch add this.

Fixes #2895

Signed-off-by: Robert C. Helling <helling@atdotde.de>
2020-07-11 10:37:49 -07:00
Linus Torvalds
628c7c8f13 Fix dive merging with multiple cylinders
We did something really horribly wrong when merging cylinders.  It's
been broken since commit 7c9f46a ("Core: remove MAX_CYLINDERS
restriction"), and used some really strange logic.

This rewrites the logic to be (I think) a bit more easy to understand.

Signed-off-by: Linus Torvalds <torvalds@linux-foundation.org>
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
2020-06-29 10:44:01 -07:00
Berthold Stoeger
87c91af824 cleanup: constify time_during_dive_with_offset() function
There is no reason to pass a non-const dive pointer as first
argument.

Signed-off-by: Berthold Stoeger <bstoeger@mail.tuwien.ac.at>
2020-05-22 14:40:49 -07:00
Berthold Stoeger
9365061e27 cleanup: remove unused function get_dive_n_near()
The last caller was removed in 7eb422d988.
Since this is the only caller of dive_within_time_range(), remove that
function as well.

Signed-off-by: Berthold Stoeger <bstoeger@mail.tuwien.ac.at>
2020-05-22 14:40:49 -07:00
Berthold Stoeger
4374605c12 undo: make adding of pictures undoable
This one is a bit hairy, because two things might happen if the
picture has a geo location:
- A dive gets a newly generated dive site set.
- The dive site of a dive is edited.
Therefore the undo command has to store keep track of that.
Oh my.

Signed-off-by: Berthold Stoeger <bstoeger@mail.tuwien.ac.at>
2020-05-06 13:58:09 -07:00
Berthold Stoeger
6ae2d36e38 core: move picture-related function from dive.c to picture.c
Move the two functions create_picture() and picture_check_valid_time()
from dive.c to picture.c.

This might be somewhat questionable, as these functions are not purely
picture related, but check the nearest selected dives, etc. However,
dive.c is so huge, that slimming it down can't hurt. Moreover,
getting the nearest selected dive is more divelist- than dive
functionality anyway.

Signed-off-by: Berthold Stoeger <bstoeger@mail.tuwien.ac.at>
2020-05-06 13:58:09 -07:00