The plain dash may look a bit too much like a trimix specification. Is
the ellipsis better? Maybe.
Signed-off-by: Linus Torvalds <torvalds@linux-foundation.org>
If you are diving multiple nitrox cylinders, we now show them as a range
instead of just the max. We'll still sort by max O2 (and for the same
max, by min O2).
So now with trimix dives, we'll show the bottom gas (we assume that
"highest He percentage" is that bottom gas), for nitrox dives we'll show
the range of Oxygen percentage, and for all-air dives we'll show just
"air".
For simple nitrox dives (only a single mix), we'll obviously show just
that single percentage. This should hopefully conclude the whole "show
multiple cylinders in dive list" mess.
Signed-off-by: Linus Torvalds <torvalds@linux-foundation.org>
.. using the regular sorting rules: sort by Helium content first, Oxygen
content second. Air always sorts last (even behind the theoretical
hypoxic Nitrox that nobody sane would use).
This is what Don Kinney implies would be the natural thing for a trimix
diver.
Signed-off-by: Linus Torvalds <torvalds@linux-foundation.org>
.. and use this for the nitrox column, which can now be more complex
than just a single number.
The rule for the "nitrox" column is now:
- we look up the highest Oxygen and Helium mix for the dive
(Note: we look them up independently, so if you have a EAN50 deco
bottle, and a 20% Helium low-oxygen bottle for the deep portion, then
we'll consider the dive to be a "50% Oxygen, 20% Helium" dive, even
though you obviously never used that combination at the same time)
- we sort by Helium first, Oxygen second. So a dive with a 10% Helium
mix is considered to be "stronger" than a 50% Nitrox mix.
- If Helium is non-zero, we show "O2/He", otherwise we show just "O2"
(or "air"). So "21/20" means "21% oxygen, 20% Helium", while "40"
means "Ean 40".
- I got rid of the decimals. We save them, and you can see them in the
dive equipment details, but for the dive list we just use rounded
percentages.
Let's see how many bugs I introduced. I don't actually have any trimix
dives, but I edited a few for (very limited) testing.
Signed-off-by: Linus Torvalds <torvalds@linux-foundation.org>
The divelist airmix display is kind of broken: it only looks at the
first cylinder, and it only looks at Oxygen content, not Helium.
But at least we can make sure to update it when somebody edits the
cylinder information, instead of leaving it extra broken.
Signed-off-by: Linus Torvalds <torvalds@linux-foundation.org>
They were never intended to be sortable, but using common code with the
dive list picked up that "sort by index" thing by mistake.
If we really want to be able to sort cylinders by O2 percentage (which
really doesn't seem to make much sense, considering that you usually
have just one or two cylinders) we will need to also handle the case of
editing the (differently sorted) cylinder table. Which we don't do now.
Reported-by: Henrik Brautaset Aronsen <subsurface@henrik.synth.no>
Signed-off-by: Linus Torvalds <torvalds@linux-foundation.org>
Round maximum depth on dive list to get consistent data between the dive
list and dive info.
Signed-off-by: Miika Turkia <miika.turkia@gmail.com>
Signed-off-by: Linus Torvalds <torvalds@linux-foundation.org>
To waste less space in the tree view heading we simply put a star in the
heading instead of "Rating".
We now treat "zero stars" to mean "not rated" and don't store that value
in the XML file.
Rating is no longer a top level tag in the dive entry but instead a
property of the dive tag.
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
This works ok-ish, but doesn't allow us to click on the stars and edit
them in the divelist, which a user might expect to be able to do - in
most "star rating UIs" you simply click on the n-th star to set that
rating. Here you need to edit the dive and pick the rating from a drop
down menu.
Minor oddity: you can actually (if you force it) write anything you want
into the star rating. But anything that isn't one of the predefined
strings simply results in a zero star rating.
Overall the UI feels a bit... forced. But I think this is quite useful
anyway.
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
We assume every sample with a depth of less than 10cm to be on the
surface.
This does not impact our interpolated pressures (one could assume that the
diver is not breathing from the regulator when on the surface - but
without air integration that's just an assumption).
It also doesn't change our tank pressure coloring by sac rate as that
always uses the momentary sac rate. Technically speaking this might impact
the actual colors printed (as those are relative to the total sac on the
dive which may go up due to this change).
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
Now that the dive info window is read-only, we need to edit the dives
some other way. We bring up a dive info edit dialog when you
double-click on the dive list entry for that dive.
I do want to have an "edit" button or keyboard shortcut or something
too, though.
Signed-off-by: Linus Torvalds <torvalds@linux-foundation.org>
* 'sacplot' of git://github.com/dirkhh/subsurface:
Color pressure plot according to current SAC rate
Fix minor coding standard issues introduced by my last commit
You can still order them by date by just setting the sort order on the
date column, but normally you'd be more interested in the most recent
dives.
I tried to just scroll down to the last ones automatically instead, but
gtk makes that *really* hard to do. If you do it in the natural place
for it, the scroll bar wll show up later and then cover up the last
entry anyway. So you'd have to do some crazy expose event thing or
something. Which may be the right thing to do eventually anyway, but
not worth the pain right now.
Signed-off-by: Linus Torvalds <torvalds@linux-foundation.org>
Randomly picked up to 60 characters. But maybe we should just get rid
of the limit entirely.
Signed-off-by: Linus Torvalds <torvalds@linux-foundation.org>
Make sure that we calculate air use by using the proper start/end
pressures, with the manually set ones being used preferentially over any
possible sample data.
Signed-off-by: Linus Torvalds <torvalds@linux-foundation.org>
Finally getting more consistent overall in how we convert between the
different units and how we decide which units to display.
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
Treat SAC and OTU consistently:
- SAC is now a member of struct dive
- it's calculated / populated at the same time with a helper function with
consistent API
Create get_volume_units function that returns volumes (e.g. used in SAC
rates) based on preferred units - make sure we have these conversions just
once in the code.
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
This is based on Linus idea and code - just adding it to my UI branch in
case he didn't actually add it to his code...
It makes no sense to sort by dive number - every sane person will have
dive numbers be chronological; so they can sort by date instead.
But removing this option wastes less space and makes the dive list look
much better
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
At this point we don't do anything with this - the commit just provides
the infrastructure changes so that this becomes possible. Subsurface
behaves the same if exactly one dive is selected and simply keeps the last
selected dive if zero or more than one dives are selected.
The goal is to be able to select multiple dives and then do actions on
them. For example pick a tank used for all of them. Or edit the location
or (yet to be implemented) other equipment data like weight carried.
And also to be able to merge multiple dives.
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
We used to do this just for the dive list, but the new cylinder view
will want to do a lot of the same boilerplate gtk stuff, so make it a
bit more generic and move it to gtk-gui.c.
Signed-off-by: Linus Torvalds <torvalds@linux-foundation.org>
The calculation assumes that the cylinderindex in each sample tells us
which PO2 the dive was breathing at that time. This needs to be verified
with dives where there is an actual gas switch.
No idea where to display them, yet. Far fewer people will care about this
than care about SAC - does this still rate a spot in the dive_list?
I guess I could make it part of the dive_info - but it's not editable.
It doesn't seem to fit with the equipment page (even though this is the
one editable field that is related - nitrox %)
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
Just seems to look nicer this way. And actually implements consistent
alignment management for the columns to begin with.
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
The whole auto-expansion of an entry in the middle thing really doesn't
work very well in gtk. Give up on it.
Signed-off-by: Linus Torvalds <torvalds@linux-foundation.org>
This is some crazy stuff. Apparently the only sane way to do this is by
hooking into the "realize" callback for the dive list widget.
Whatever. Dirk did the googling to figure this all out.
Suggested-by: Dirk Hohndel <dirk@hohndel.org>
Signed-off-by: Linus Torvalds <torvalds@linux-foundation.org>
We should always strive to have a dive selected, so pick the first one
(that was how the dive list logic worked anyway, it just wasn't truly
selected at the tree-view level, so it wasn't *visibly* the selected
dive).
Signed-off-by: Linus Torvalds <torvalds@linux-foundation.org>
It used to be "index 0" which originally was the date string, but not
only has that changed (it's now just the dive index), it's kind of
pointless to search for a date string.
Signed-off-by: Linus Torvalds <torvalds@linux-foundation.org>
Show "m" or "ft" instead of "max/m" vs "max/ft". The column really
doesn't want to be that wide. The column header is already the widest
part of it even with this short name (due to the sort order arrow
thing).
Signed-off-by: Linus Torvalds <torvalds@linux-foundation.org>
Track whether things changed in the global dive_list
So far this actually works if changing dive info (but only if dive
selected was changed after the dive info was changed).
We are not tracking changes to the cylinder information, yet.
also remove the duplicate static dive_list
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
Use the actual degree sign for temperatures (°F and °C), and make sure
everything uses the proper "set_source_rgb[a]()" wrappers to set the
colors.
Signed-off-by: Linus Torvalds <torvalds@linux-foundation.org>
That was stupid. The divelist column generation cleanup (commit
d3feb78df5: "Make helper function for creating TreeView columns in the
dive list") had a but too much copy-paste going on, and didn't always
have the right column indexes.. t still *looked* right, but sorting
didn't work at all.
Reported-by: Chris Lewis <chrislewis915@gmail.com>
Signed-off-by: Linus Torvalds <torvalds@linux-foundation.org>
The following are UI toolkit specific:
gtk-gui.c - overall layout, main window of the UI
divelist.c - list of dives subsurface maintains
equipment.c - equipment / tank information for each dive
info.c - detailed dive info
print.c - printing
The rest is independent of the UI:
main.c i - program frame
dive.c i - creates and maintaines the internal dive list structure
libdivecomputer.c
uemis.c
parse-xml.c
save-xml.c - interface with dive computers and the XML files
profile.c - creates the data for the profile and draws it using cairo
This commit should contain NO functional changes, just moving code around
and a couple of minor abstractions.
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
Instead of the hardcoding to "Sans 8", allow people to set it in the
preferences.
Also, make the unit choice be a frame in the preferences dialog instead.
Signed-off-by: Linus Torvalds <torvalds@linux-foundation.org>
* 'for-linus' of git://github.com/dirkhh/subsurface:
Attempt to get the location column to resize in a sensible way
Minor tweaks to column headers
[ Fixed up minor semantic merge conflict due to the change to make
'dive_list' internal to divelist.c ]
Passing it around is just annoying, and we only ever have one. Let's
not burden all the users with the silly thing.
Signed-off-by: Linus Torvalds <torvalds@linux-foundation.org>
Previously the SAC column was the one that expanded which is silly
We also used to cut the location off at 16 characters
Now we try to make the location the one that expands and allow up to 40
characters, but there's something broken, still. If you manually shrink
the location column to its minimum size then subsequently resizing the
window gets the desired behavior. But if you don't manually resize the
location column it doesn't shrink correctly for windows that are smaller
than the space we need for all columns to fully display (instead we get a
horizontal scrollbar)
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
It got removed by some of my overly aggressive cleanup in commit
fefcbf125e ("Remove dive info frame") because the dive info frame
initialization also initialized the main window title..
Signed-off-by: Linus Torvalds <torvalds@linux-foundation.org>
This really is too wrong for words, but I do think the dive list may
look better with a smaller font.
Signed-off-by: Linus Torvalds <torvalds@linux-foundation.org>