Previous formula didn't handle values of less than 10 correctly.
Signed-off-by: Miika Turkia <miika.turkia@gmail.com>
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
If pressure field is empty, we do not want to have field separator as
pressure value. This would flood the console with parsing error
messages.
Signed-off-by: Miika Turkia <miika.turkia@gmail.com>
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
Assume a format containing a dot to be min.sec as defined in DL7
specification.
Signed-off-by: Miika Turkia <miika.turkia@gmail.com>
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
Include the DC's hardware name if it was given as parameter on CSV
import.
Signed-off-by: Miika Turkia <miika.turkia@gmail.com>
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
This looks if we're importing any o2 values form the csv file, then its
probably a CCR dive.
Signed-off-by: Anton Lundin <glance@acc.umu.se>
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
Instead of replacing all the empty model tags after a csv to xml
transform with some text, just produce that text in the csv to xml
transform instead.
Signed-off-by: Anton Lundin <glance@acc.umu.se>
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
This adds support for importing individual O2 sensors from a CSV file,
e.g. an APD log viewer file.
Signed-off-by: Anton Lundin <glance@acc.umu.se>
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
This add support for Seabear's new import format that is used by H3 and
T1. In the future also the Hudc should switch to the new format. The
main difference to the old one is that time stamps are no longer
recorded in the samples, but intervali is specified in the header.
The header contains other useful information as well that we should
build support for. E.g. surface pressure, gas mixes, GF, and mode might
be useful additions later on.
Signed-off-by: Miika Turkia <miika.turkia@gmail.com>
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
Implementation of getFieldByIndex on this file does not support
quotation so lets use a template that is developed further.
Signed-off-by: Miika Turkia <miika.turkia@gmail.com>
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
On CSV import the time can be represented with seconds, min:sec or
hour:min:sec. This patch adds support for the min:sec format that was
missing.
See #662
Signed-off-by: Miika Turkia <miika.turkia@gmail.com>
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
Empty values included the rest of the line in the value, instead of
leaving it empty. This patch leaves empty values empty.
Signed-off-by: Miika Turkia <miika.turkia@gmail.com>
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
We want to skip duplicate lines on CSV import. For this we need to use
time field, that is not necessarily the first field of the input. This
patch uses the configured time field instead of first one.
Signed-off-by: Miika Turkia <miika.turkia@gmail.com>
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
After change to include XSLT files in resources, the import quit
working (even though the files and templates were found properly). This
patch uses include statement instead as it seems to work in our case.
Signed-off-by: Miika Turkia <miika.turkia@gmail.com>
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
The separator selector in the CSV import dialog was unused. This passes
the value into the xslt and adds ',' as possible value.
I'm sure this could be done much better (pass the actual character instead
of the index), but I couldn't get that to work and this does seem to do
the trick.
Also added a test dive to test this feature.
Fixes#321
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
Use if around the attribute, instead if a choose inside. Its less
horrible on the eyes.
Signed-off-by: Anton Lundin <glance@acc.umu.se>
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
I managed to mess up and grab parts of my unfinished otu field code and
squash it into the wrong patch. Here is the code for stopdepth, and now
the code sets the in_deco flag to.
Signed-off-by: Anton Lundin <glance@acc.umu.se>
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
This adds a checkbox to be able to import csv files without temperature.
Signed-off-by: Anton Lundin <glance@acc.umu.se>
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>