Remove the preference settings dealing with thumbnails (currently under
General preferences and Profile preferences) and put them in a newly-created
Media preference tab.
Signed-off-by: willemferguson <willemferguson@zoology.up.ac.za>
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
Remove the "Show unused cylinders" checkbox (Profile tab) and the
"Set default cylinder" qTextEdit box (General tab) and put them in a
separate and new Equipment tab. This sounds like a simple task but,
as can be seen from the files changed, was actually a complex matter.
Adapt the existing test programs (General and TechDetails) for creating
a test program that tests parts of the Equipment tab.
Signed-off-by: willemferguson <willemferguson@zoology.up.ac.za>
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
This changes the above mentioned terms everywhere in the UI to
reflect the fact that Subsurface now also supports video files on top
of image files.
Signed-off-by: Stefan Fuchs <sfuchs@gmx.de>
If a thumbnail and the original picture can be accessed and the
modification date of the thumbnail is before the modification date
of the picture, recalculate the thumbnail.
This causes more disk access and might give strange effects for
picture files with messed up file timestamps (i.e. lying in the
future) or messed up computer clocks (i.e. running in the past).
Therefore, add a preference option to disable the new behavior.
Default is set to enabled.
Signed-off-by: Berthold Stoeger <bstoeger@mail.tuwien.ac.at>
This commit allows plotting the OC-equivalent pO2 graph for PSCR
dives. This happens in both the cases where there is no external
O2-monitoring AND when there is external pO2 monitoring. The
calculations are only done for PSCR dives and is achieved as
follows:
1) Within plot-info create a pressure-t called OC_pO2 in
profile.h and populate this variable with the open-circuit
pO2 values in profile.c.
2) Create a new partialPressureGasItem ocpo2GasItem in
profilewidget2.h and, in profilewidget2.cpp, initialise it
to read the plot-info OC_pO2 values and enable its
display by using the setVisible method. The
diveplotdatamodel was also touched in order to achieve
this.
3) Create a pref button that controls the display of OC-pO2 for SCR dives
4) Change the colour of the OC-pO2 grpah to orange
5) Change the connection of the crr_OC_pO2 signal to be appropriate
6) rename the OC_pO2 attribute to scr_OC-pO2
Signed-off-by: Willem Ferguson <willemferguson@zoology.up.ac.za>
Move the icd preference setting to the preference group that deals
with gas pressures.
I also reorganised the existing items so that the items within the
pressure widget are logically arranged according to the grid layout.
The order of items was very haphazard. No change of code at all in
this reorganisation.
Signed-off-by: Willem Ferguson <willemferguson@zoology.up.ac.za>
This option should have never been there. This is not how
gradient factors are supposed to work. It would only trick
users to use the wrong value..
Signed-off-by: Robert C. Helling <helling@atdotde.de>
Stefan suggested "Maybe it would be nicer to move the 3 fields for the
maximum pressure for N2, He, O2 for MOD to the right in the UI window
exactly below the maximum field for the O2 (where we now have
minimum + maximum)."
And I agree, so this is the change.
At the same time, reset the tab-order to a logical one.
Reported-by: Stefan Fuchs <sfuchs@gmx.de>
Signed-off-by: Jan Mulder <jlmulder@xs4all.nl>
Nothing really special here. Just a split of the only p02 max threshold into
a min threshold and max threshold, and the adaptation of the UI. Change of
translatable strings included.
ref: https://github.com/Subsurface-divelog/subsurface/issues/259
Signed-off-by: Jan Mulder <jlmulder@xs4all.nl>
In preferences->profile:
Move "bar" from text description to entry field (5x)
Move "l/min" from text description to entry field
Add suffix "%" to GF values
Rename VPM-B conservatism
In planner preferences:
Add prefix "+" to VPM-B conservatism
Signed-off-by: Stefan Fuchs <sfuchs@gmx.de>
Remove one last leading space character that I missed.
Signed-off-by: Willem Ferguson <willemferguson@zoology.up.ac.za>
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
This reorganises the Preferences->Graph tab.
All leading spaces have been removed for labels and text fields.
Signed-off-by: Willem Ferguson <willemferguson@zoology.up.ac.za>
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
1) Reorganise existing items in Graph tab so that all gass pressure
items are together and all profile-related items are together.
2) Provide units (mostly bar) for all settings having units.
Signed-off-by: Willem Ferguson <willemferguson@zoology.up.ac.za>
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
Separate the VPM-B conservatism preference into diveplan.vpmb_conservatism for
planning dives and prefs.vpmb_conservatism for profile ceiling display of
saved dives.
Signed-off-by: Rick Walsh <rickmwalsh@gmail.com>
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
When 'tabbing' through data fields, the order should be the same as the order
displayed on the screen. Getting the order right in the .ui file fixes the
tabstop order without needing to define it explicitly.
Signed-off-by: Rick Walsh <rickmwalsh@gmail.com>
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
Let's have the preferences window as small as possible with the current
data in it. This should allow people with vertical resolution of 600 to
use the preferences window.
Fixes#1083
Signed-off-by: Miika Turkia <miika.turkia@gmail.com>
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
As pointed by jwhferguson, I changed "show average depth" to "show
mean depth".
I modified file preferences_graph.ui and changed the text. This bug was
reported on fedora 22. i use ubuntu.layout and justification is nicely
displayed.
The patch also removes a no longer necessary include.
See #922
Signed-off-by: krisalpha <choprakrishan61@gmail.com>
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>