subsurface/profile-widget/diveeventitem.cpp
Michael Keller 1309064873 Profile: Reinstate Hiding of Events by Type across Dives.
Reinstate the hiding of events by event type across
all dives in the log. This was unintentionally removed in #3948.
Also change the event type to be specific to name and severity, and fix
bug causing 'Unhide all events' to not show when only individual events
were hidden.

This still leaves the inconsistency that hiding of similar events is
persisted across the switch between dives, but hiding of individual
events is lost when switching dives, which is mildly confusing.

Follow-up to #4092.

Signed-off-by: Michael Keller <github@ike.ch>
2024-02-12 12:27:59 +01:00

245 lines
8.5 KiB
C++

// SPDX-License-Identifier: GPL-2.0
#include "profile-widget/diveeventitem.h"
#include "profile-widget/divecartesianaxis.h"
#include "profile-widget/divepixmapcache.h"
#include "profile-widget/animationfunctions.h"
#include "core/event.h"
#include "core/eventname.h"
#include "core/format.h"
#include "core/profile.h"
#include "core/gettextfromc.h"
#include "core/sample.h"
#include "core/subsurface-string.h"
#define DEPTH_NOT_FOUND (-2342)
static int depthAtTime(const plot_info &pi, duration_t time);
DiveEventItem::DiveEventItem(const struct dive *d, struct event *ev, struct gasmix lastgasmix,
const plot_info &pi, DiveCartesianAxis *hAxis, DiveCartesianAxis *vAxis,
int speed, const DivePixmaps &pixmaps, QGraphicsItem *parent) : DivePixmapItem(parent),
vAxis(vAxis),
hAxis(hAxis),
ev(ev),
dive(d),
depth(depthAtTime(pi, ev->time))
{
setFlag(ItemIgnoresTransformations);
setupPixmap(lastgasmix, pixmaps);
setupToolTipString(lastgasmix);
recalculatePos();
}
DiveEventItem::~DiveEventItem()
{
}
const struct event *DiveEventItem::getEvent() const
{
return ev;
}
struct event *DiveEventItem::getEventMutable()
{
return ev;
}
void DiveEventItem::setupPixmap(struct gasmix lastgasmix, const DivePixmaps &pixmaps)
{
if (empty_string(ev->name)) {
setPixmap(pixmaps.warning);
} else if (same_string_caseinsensitive(ev->name, "modechange")) {
if (ev->value == 0)
setPixmap(pixmaps.bailout);
else
setPixmap(pixmaps.onCCRLoop);
} else if (ev->type == SAMPLE_EVENT_BOOKMARK) {
setPixmap(pixmaps.bookmark);
setOffset(QPointF(0.0, -pixmap().height()));
} else if (event_is_gaschange(ev)) {
struct gasmix mix = get_gasmix_from_event(dive, ev);
struct icd_data icd_data;
bool icd = isobaric_counterdiffusion(lastgasmix, mix, &icd_data);
if (mix.he.permille) {
if (icd)
setPixmap(pixmaps.gaschangeTrimixICD);
else
setPixmap(pixmaps.gaschangeTrimix);
} else if (gasmix_is_air(mix)) {
if (icd)
setPixmap(pixmaps.gaschangeAirICD);
else
setPixmap(pixmaps.gaschangeAir);
} else if (mix.o2.permille == 1000) {
if (icd)
setPixmap(pixmaps.gaschangeOxygenICD);
else
setPixmap(pixmaps.gaschangeOxygen);
} else {
if (icd)
setPixmap(pixmaps.gaschangeEANICD);
else
setPixmap(pixmaps.gaschangeEAN);
}
#ifdef SAMPLE_FLAGS_SEVERITY_SHIFT
} else if ((((ev->flags & SAMPLE_FLAGS_SEVERITY_MASK) >> SAMPLE_FLAGS_SEVERITY_SHIFT) == 1) ||
// those are useless internals of the dive computer
#else
} else if (
#endif
same_string_caseinsensitive(ev->name, "heading") ||
(same_string_caseinsensitive(ev->name, "SP change") && ev->time.seconds == 0)) {
// 2 cases:
// a) some dive computers have heading in every sample
// b) at t=0 we might have an "SP change" to indicate dive type
// in both cases we want to get the right data into the tooltip but don't want the visual clutter
// so set an "almost invisible" pixmap (a narrow but somewhat tall, basically transparent pixmap)
// that allows tooltips to work when we don't want to show a specific
// pixmap for an event, but want to show the event value in the tooltip
setPixmap(pixmaps.transparent);
#ifdef SAMPLE_FLAGS_SEVERITY_SHIFT
} else if (((ev->flags & SAMPLE_FLAGS_SEVERITY_MASK) >> SAMPLE_FLAGS_SEVERITY_SHIFT) == 2) {
setPixmap(pixmaps.info);
} else if (((ev->flags & SAMPLE_FLAGS_SEVERITY_MASK) >> SAMPLE_FLAGS_SEVERITY_SHIFT) == 3) {
setPixmap(pixmaps.warning);
} else if (((ev->flags & SAMPLE_FLAGS_SEVERITY_MASK) >> SAMPLE_FLAGS_SEVERITY_SHIFT) == 4) {
setPixmap(pixmaps.violation);
#endif
} else if (same_string_caseinsensitive(ev->name, "violation") || // generic libdivecomputer
same_string_caseinsensitive(ev->name, "Safety stop violation") || // the rest are from the Uemis downloader
same_string_caseinsensitive(ev->name, "pO₂ ascend alarm") ||
same_string_caseinsensitive(ev->name, "RGT alert") ||
same_string_caseinsensitive(ev->name, "Dive time alert") ||
same_string_caseinsensitive(ev->name, "Low battery alert") ||
same_string_caseinsensitive(ev->name, "Speed alarm")) {
setPixmap(pixmaps.violation);
} else if (same_string_caseinsensitive(ev->name, "non stop time") || // generic libdivecomputer
same_string_caseinsensitive(ev->name, "safety stop") ||
same_string_caseinsensitive(ev->name, "safety stop (voluntary)") ||
same_string_caseinsensitive(ev->name, "Tank change suggested") || // Uemis downloader
same_string_caseinsensitive(ev->name, "Marker")) {
setPixmap(pixmaps.info);
} else {
// we should do some guessing based on the type / name of the event;
// for now they all get the warning icon
setPixmap(pixmaps.warning);
}
}
void DiveEventItem::setupToolTipString(struct gasmix lastgasmix)
{
// we display the event on screen - so translate
QString name = gettextFromC::tr(ev->name);
int value = ev->value;
int type = ev->type;
if (event_is_gaschange(ev)) {
struct icd_data icd_data;
struct gasmix mix = get_gasmix_from_event(dive, ev);
name += ": ";
name += gasname(mix);
/* Do we have an explicit cylinder index? Show it. */
if (ev->gas.index >= 0)
name += tr(" (cyl. %1)").arg(ev->gas.index + 1);
bool icd = isobaric_counterdiffusion(lastgasmix, mix, &icd_data);
if (icd_data.dHe < 0) {
name += qasprintf_loc("\n%s %s:%+.3g%% %s:%+.3g%%%s%+.3g%%",
qPrintable(tr("ICD")),
qPrintable(tr("ΔHe")), icd_data.dHe / 10.0,
qPrintable(tr("ΔN₂")), icd_data.dN2 / 10.0,
icd ? ">" : "<", lrint(-icd_data.dHe / 5.0) / 10.0);
}
} else if (same_string(ev->name, "modechange")) {
name += QString(": %1").arg(gettextFromC::tr(divemode_text_ui[ev->value]));
} else if (value) {
if (type == SAMPLE_EVENT_PO2 && same_string(ev->name, "SP change")) {
name += QString(": %1bar").arg((double)value / 1000, 0, 'f', 1);
} else if (type == SAMPLE_EVENT_CEILING && same_string(ev->name, "planned waypoint above ceiling")) {
const char *depth_unit;
double depth_value = get_depth_units(value*1000, NULL, &depth_unit);
name += QString(": %1%2").arg((int) round(depth_value)).arg(depth_unit);
} else {
name += QString(": %1").arg(value);
}
} else if (type == SAMPLE_EVENT_PO2 && same_string(ev->name, "SP change")) {
// this is a bad idea - we are abusing an existing event type that is supposed to
// warn of high or low pO₂ and are turning it into a setpoint change event
name += ":\n" + tr("Manual switch to OC");
} else {
name += ev->flags & SAMPLE_FLAGS_BEGIN ? tr(" begin", "Starts with space!") :
ev->flags & SAMPLE_FLAGS_END ? tr(" end", "Starts with space!") : "";
}
setToolTip(QString("<img height=\"16\" src=\":status-warning-icon\">&nbsp; ") + name);
}
void DiveEventItem::eventVisibilityChanged(const QString&, bool)
{
//WARN: lookslike we should implement this.
}
static int depthAtTime(const plot_info &pi, duration_t time)
{
// Do a binary search for the timestamp
auto it = std::lower_bound(pi.entry, pi.entry + pi.nr, time,
[](const plot_data &d1, duration_t t) { return d1.sec < t.seconds; });
if (it == pi.entry + pi.nr || it->sec != time.seconds) {
qWarning("can't find a spot in the dataModel");
return DEPTH_NOT_FOUND;
}
return it->depth;
}
bool DiveEventItem::isInteresting(const struct dive *d, const struct divecomputer *dc,
const struct event *ev, const plot_info &pi,
int firstSecond, int lastSecond)
{
/*
* Ignore items outside of plot range
*/
if (ev->time.seconds < firstSecond || ev->time.seconds >= lastSecond)
return false;
/*
* Some gas change events are special. Some dive computers just tell us the initial gas this way.
* Don't bother showing those
*/
const struct sample *first_sample = &dc->sample[0];
if (!strcmp(ev->name, "gaschange") &&
(ev->time.seconds == 0 ||
(first_sample && ev->time.seconds == first_sample->time.seconds) ||
depthAtTime(pi, ev->time) < SURFACE_THRESHOLD))
return false;
/*
* Some divecomputers give "surface" events that just aren't interesting.
* Like at the beginning or very end of a dive. Well, duh.
*/
if (!strcmp(ev->name, "surface")) {
int time = ev->time.seconds;
if (time <= 30 || time + 30 >= (int)dc->duration.seconds)
return false;
}
return true;
}
bool DiveEventItem::shouldBeHidden()
{
return is_event_hidden(ev->name, ev->flags);
}
void DiveEventItem::recalculatePos()
{
if (!ev)
return;
if (depth == DEPTH_NOT_FOUND) {
hide();
return;
}
setVisible(!shouldBeHidden());
double x = hAxis->posAtValue(ev->time.seconds);
double y = vAxis->posAtValue(depth);
setPos(x, y);
}