Commit graph

134 commits

Author SHA1 Message Date
Dirk Hohndel
27c49fe3ad Silence random warnings
None of these seem to point to actual issues, so let's quiet them.

Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
2017-10-20 17:25:18 -04:00
Stefan Fuchs
022b3e450b Translate dc text in profile also if string has suffix for > 1 DC
Signed-off-by: Stefan Fuchs <sfuchs@gmx.de>
2017-10-20 06:38:20 -04:00
Stefan Fuchs
c3274b0b9f When selecting icons for events don't misinterpret a gaschange
Don't misinterpret a gaschange as "useless internal of the dive computer"
when it has a higher flag value.

Signed-off-by: Stefan Fuchs <sfuchs@gmx.de>
2017-10-19 19:00:55 -04:00
Robert C. Helling
a422957cd6 Use displayed_dc instead of current_dc
current_dc is a macro that determines the dive computer
based on the current dive number. When the planner is started
from an emtpy dive list, the dive number ends up being -1 and
that doesn't produce a valid dive computer. Use the divecomputer
of the displayed_dive instead. This is done via a macro that
can also be used in two other places. Without this patch, the
planner crashed when called on an empty dive list.

Signed-off-by: Robert C. Helling <helling@atdotde.de>
2017-10-19 14:57:02 -04:00
Stefan Fuchs
fcc4be6ea0 Add a icon for gaschange to Oxy with all green tank shoulder color
Signed-off-by: Stefan Fuchs <sfuchs@gmx.de>
2017-10-18 06:47:44 -04:00
Robert C. Helling
432110ac8f Find current gasmix for heatmap
To compute the heatmap value, we need the current gasmix but
the current cylinderindex is no longer available.

Fixes #562

Suggested-by: Linus Torvalds <torvalds@linux-foundation.org>
Signed-off-by: Robert C. Helling <helling@atdotde.de>
2017-10-18 06:34:15 -04:00
Stefan Fuchs
c3857db23b Hide outdated gas name strings in profile in planner
When deleting dive planner points in the planner we currently sometimes
miss to hide the outdated gas name strings printed close to the profile
legs.

Signed-off-by: Stefan Fuchs <sfuchs@gmx.de>
2017-10-08 23:19:23 +02:00
Stefan Fuchs
8d8e694b0d End tankbar at the correct end of the dive plot
Go back to the old startegy of retrieving the correct end of the dive
plot by looking at the plot data instead of looking at dc->duration.

Signed-off-by: Stefan Fuchs <sfuchs@gmx.de>
2017-09-15 09:01:10 -07:00
Dirk Hohndel
96ed09bf14 Update the tankbar code to work with the new gas handling
When Linus modified the gas handling code six weeks ago he pointed out
that that had broken the tankbar; with this patch we now simply walk the
gas changes of the displayed dive directly and create the tankbar
rectangles from that information.

See #562

Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
2017-09-14 05:36:52 +02:00
Dirk Hohndel
aabcff9c54 Move unused code into the disabled block
These varaiables are only used in the code that we currently
aren't compiling.

Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
2017-08-26 12:11:44 -07:00
Linus Torvalds
e04ef1df1e Fix the overprinting of gas name and pressure value on the profile
When I massaged the code to do multiple gas pressures in commit e1b880f4
("Profile support for multiple concurrent pressure sensors") some of the
Y offsetting code got cut out as being too specific to the old
o2pressure code.

But I removed a bit too much, leaving the label (gas name) and number
(gas pressure) overlapping.

This should fix it.

If we really care about multiple gas pressure labels overlapping each
other, we'll have to revisit this code, but the old two-gas case didn't
do a very good job either (both that old code - and this new version -
can look very good in particular cases, but there are cases where it
won't work so well).

So we may need to revisit this eventually, but this gets it looking fine
for the normal cases.

Reported-by: Miika Turkia <miika.turkia@gmail.com>
Signed-off-by: Linus Torvalds <torvalds@linux-foundation.org>
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
2017-08-07 00:57:58 -07:00
Linus Torvalds
e1b880f444 Profile support for multiple concurrent pressure sensors
This finally handles multiple cylinder pressures, both overlapping and
consecutive, and it seems to work on the nasty cases I've thrown at it.

Want to just track five different cylinders all at once, without any
pesky gas switch events? Sure, you can do that.  It will show five
different gas pressures for your five cylinders, and they will go down
as you breathe down the cylinders.

I obviously don't have any real data for that case, but I do have a test
file with five actual cylinders that all have samples over the whole
course of the dive.  The end result looks messy as hell, but what did
you expect?

HOWEVER.

The only way to do this sanely was

 - actually make the "struct plot_info" have all the cylinder pressures
   (so no "sensor index and pressure" - every cylinder has a pressure for
   every plot info entry)

   This obviously makes the plot_info much bigger. We used to have
   MAX_CYLINDERS be a fairly generous 8, which seems sane. The planning
   code made that 8 be 20. That seems questionable. But whatever.

   The good news is that the plot-info should hopefully get freed, and
   only be allocated one dive at a time, so the fact that it is big and
   nasty shouldn't be a scaling issue, though.

 - the "populate_pressure_information()" function had to be rewritten
   quite a bit. The good news is that it's actually simpler now, although
   I would not go so far as to really call it simple. It's still
   complicated and suble, but now it explicitly just does one cylinder at
   a time.

   It *used* to have this insanely complicated "keep track of the pressure
   ranges for every cylinder at once". I just couldn't stand that model
   and keep my sanity, so it now just tracks one cylinder at a time, and
   doesn't have an array of live data, instead the caller will just call
   it for each cylinder.

 - get rid of some of our hackier stuff, like the code that populates the
   plot_info data code with the currently selected cylinder number, and
   clears out any other pressures. That obviously does *not* work when you
   may not have a single primary cylinder any more.

Now, the above sounds like all good things. Yeah, it mostly is.

BUT.

There's a few big downsides from the above:

 - there's no sane way to do this as a series of small changes.

   The change to make the plot_info take an array of cylinder pressures
   rather than the sensor+pressure model really isn't amenable to "fix up
   one use at a time". When you switch over to the new data structure
   model, you have to switch over to the new way of populating the
   pressure ranges. The two just go hand in hand.

 - Some of our code *depended* on the "sensor+pressure" model. I fixed all
   the ones I could sanely fix. There was one particular case that I just
   couldn't sanely fix, and I didn't care enough about it to do something
   insane.

   So the only _known_ breakage is the "TankItem" profile widget. That's
   the bar at the bottom of the profile that shows which cylinder is in
   use right now. You'd think that would be trivial to fix up, and yes it
   would be - I could just use the regular model of

     firstcyl = explicit_first_cylinder(dive, dc)
     .. then iterate over the gas change events to see the others ..

   but the problem with the "TankItem" widget is that it does its own
   model, and it has thrown away the dive and the dive computer
   information. It just doesn't even know. It only knows what cylinders
   there are, and the plot_info. And it just used to look at the sensor
   number in the plot_info, and be done with that. That number no longer
   exists.

 - I have tested it, and I think the code is better, but hey, it's a
   fairly large patch to some of the more complex code in our code base.
   That "interpolate missing pressure fields" code really isn't pretty. It
   may be prettier, but..

Anyway, without further ado, here's the patch. No sign-off yet, because I
do think people should look and comment. But I think the patch is fine,
and I'll fix anythign that anybody can find, *except* for that TankItem
thing that I will refuse to touch. That class is ugly. It needs to have
access to the actual dive.

Note how it actually does remove more lines than it adds, and that's
despite added comments etc. The code really is simpler, but there may be
cases in there that need more work.

Known missing pieces that don't currently take advantage of concurrent
cylinder pressure data:

 - the momentary SAC rate coloring for dives will need more work

 - dive merging (but we expect to generally normally not merge dive
   computers, which is the main source of sensor data)

 - actually taking advantage of different sensor data from different
   dive computers

But most of all: Testing.  Lots and lots of testing to find all the
corner cases.

Signed-off-by: Linus Torvalds <torvalds@linux-foundation.org>
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
2017-07-27 14:45:58 -07:00
Linus Torvalds
342391e0d1 Show multiple gas pressures in the profile even if the dive isn't CCR
Now that the cylinder pressures are more generalized, we should show
them even for non-CCR dives if we have them.  The most notable example
would be having separate pressure transmitters for both cylinders in a
sidemount setup. The code no longer really depends on any CCR logic.

NOTE! This is still preparatory work, in that this is one part of
supporting multiple simulataneous cylinder pressures, but we are still
lacking in other departments (eg properly filling those fields in when a
dive computer exports multiple pressure sensors etc).

Signed-off-by: Linus Torvalds <torvalds@linux-foundation.org>
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
2017-07-22 10:38:32 -07:00
Linus Torvalds
1e38d9239a Start cleaning up sensor indexing for multiple sensors
This is a very timid start at making us actually use multiple sensors
without the magical special case for just CCR oxygen tracking.

It mainly does:

 - turn the "sample->sensor" index into an array of two indexes, to
   match the pressures themselves.

 - get rid of dive->{oxygen_cylinder_index,diluent_cylinder_index},
   since a CCR dive should now simply set the sample->sensor[] indices
   correctly instead.

 - in a couple of places, start actually looping over the sensors rather
   than special-case the O2 case (although often the small "loops" are
   just unrolled, since it's just two cases.

but in many cases we still end up only covering the zero sensor case,
because the CCR O2 sensor code coverage was fairly limited.

It's entirely possible (even likely) that this migth break some existing
case: it tries to be a fairly direct ("stupid") translation of the old
code, but unlike the preparatory patch this does actually does change
some semantics.

For example, right now the git loader code assumes that if the git save
data contains a o2pressure entry, it just hardcodes the O2 sensor index
to 1.

In fact, one issue is going to simply be that our file formats do not
have that multiple sensor format, but instead had very clearly encoded
things as being the CCR O2 pressure sensor.

But this is hopefully close to usable, and I will need feedback (and
maybe test cases) from people who have existing CCR dives with pressure
data.

Signed-off-by: Linus Torvalds <torvalds@linux-foundation.org>
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
2017-07-21 16:33:19 -07:00
Stefan Fuchs
b8347d2387 Translate the strings "planned dive" and "manually added dive" in the profile
Signed-off-by: Stefan Fuchs <sfuchs@gmx.de>
2017-06-22 10:38:54 +09:00
Jan Mulder
26a0e741b8 code cleanup: remove unimplemented classes and structs
Remove forward declared but not implemented classes and structs.

Signed-off-by: Jan Mulder <jlmulder@xs4all.nl>
2017-06-16 05:31:41 +09:00
Robert C. Helling
98a65b7157 Display gas density instead of SAC in planner
In the planner, the SAC is prescribed, so there is little
use in plotting it (as the color of the cylinder pressure
line). Rather use the color to show the density of breathing
gas.

Signed-off-by: Robert C. Helling <helling@atdotde.de>
2017-05-26 15:52:04 -07:00
Robert C. Helling
53a8075bd8 Fix right boundary when moving last handle in planner
There was a bug in the old code due to confusion between minutes
and seconds as the unit of the time axis. But rather than limiting
the time for the last handle in terms of the time axis (which
potentially includes long deco and allowing that for bottom time
quickly leads to dives many many hours long) limit it to 150%
of the previous bottom time.

Signed-off-by: Robert C. Helling <helling@atdotde.de>
2017-05-26 15:46:41 -07:00
Dirk Hohndel
49d0bb8406 Add SPDX header to profile widgets
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
2017-04-29 13:32:55 -07:00
Jan Mulder
5a235aea12 minimal pO2 threshold: color the p02 graph also for minumum
Color the p02 graph also in red for going under the minumum p02 value as
set in the Preferences.

Signed-off-by: Jan Mulder <jlmulder@xs4all.nl>
2017-03-28 11:17:03 -07:00
Jan Mulder
bb31c77597 minimal pO2 threshold: split max threshold into min and max
Nothing really special here. Just a split of the only p02 max threshold into
a min threshold and max threshold, and the adaptation of the UI. Change of
translatable strings included.

ref: https://github.com/Subsurface-divelog/subsurface/issues/259

Signed-off-by: Jan Mulder <jlmulder@xs4all.nl>
2017-03-28 11:17:03 -07:00
Joakim Bygdell
bd0c99dfb7 MOBILE: Display pO2 and Setpoint for CCR dives
For CCR dives we want to display the setpoint and pO2 information,
due to the limited screensize we have to remove the temperature graph or
the view will be to cluttered.

Signed-off-by: Joakim Bygdell <j.bygdell@gmail.com>
2017-03-26 21:57:57 -07:00
Jeremie Guichard
597539ce39 Fix double to int truncation in C++ code
Wfloat-conversion enabled for C++ part of the code
Fix warnings raised by the flag using lrint

Original issue reported on the mailing list:
The ascent/descent rates are sometimes not what is expected.
E.g. setting the ascent rate to 10m/min results in an actual
ascent rate of 9m/min.
This is due to truncating the ascent rate preference,
then effectively rounding up the time to reach each stop to 2s intervals.
The result being that setting the ascent rate to 10m/min
results in 20s to ascend 3m (9m/min), when it should be exactly 18s.

Reported-by: John Smith <noseygit@hotmail.com>
Reported-by: Rick Walsh <rickmwalsh@gmail.com>
Signed-off-by: Jeremie Guichard <djebrest@gmail.com>
2017-03-24 09:39:25 -07:00
Dirk Hohndel
08284275e7 Merge branch 'master' of https://github.com/dje29/subsurface 2017-03-11 08:41:41 -08:00
Martin Měřinský
95d5771513 We use 'setpoint' in UI. Use it also for documentation and comments. No semantic change. 2017-03-11 08:09:07 -08:00
Martin Měřinský
dcf2542215 Use abbreviations with dots. 2017-03-11 08:09:07 -08:00
Robert C. Helling
eae4bd82a5 Change type of divedatepoint.depth to depth_t
... for consistency, while we are at it.

There are still some internal depth variables which are ints
somebody might take a go at those.

Signed-off-by: Robert C. Helling <helling@atdotde.de>
2017-03-11 08:03:25 -08:00
Jeremie Guichard
406e4287eb Change calls to rint into lrint avoiding conversion warnings
Using gcc option "-Wfloat-conversion" is useful to catch
potential conversion errors (where lrint should be used).
rint returns double and still raises the same warning,
this is why this change updates all rint calls to lrint.
In few places, where input type is a float, corresponding
lrinf is used.

Signed-off-by: Jeremie Guichard <djebrest@gmail.com>
2017-03-08 14:04:17 +07:00
Martin Měřinský
b14301a84c heartrate, heartbeat > heart rate 2017-03-04 12:08:17 -08:00
Martin Měřinský
59d18a00db divecomputer > dive computer 2017-03-04 12:08:17 -08:00
Stefan Fuchs
7eda24d6b1 Correct "set-point" -> "setpoint" and window title setpoint change
Change 2x "set-point" to "setpoint".
Correct window title for "Add setpoint change" window.

Signed-off-by: Stefan Fuchs <sfuchs@gmx.de>
2017-03-04 12:04:20 -08:00
Stefan Fuchs
508387b1e1 Add units and nicer formating for items in profile info box
"SP change" info format in info box: Added/changed formating and add "bar" unit.
"waypoint above ceiling" event in info box: Added formating, depth conversation to ft/m and depth unit.

Signed-off-by: Stefan Fuchs <sfuchs@gmx.de>
2017-02-21 13:11:19 -08:00
Stefan Fuchs
b39b641a05 Translate names of additional dive events and nicer format info box text
Enable translation for a few additional internal dive events.
Ensure that all event names in datatrak.c are collected for translation.
Ensure that for gaschange in profile info box the "cyl." string is also translated.

Signed-off-by: Stefan Fuchs <sfuchs@gmx.de>
2017-02-21 13:11:19 -08:00
Joakim Bygdell
12c33a038f Mobile: Do not show tankbar for CCR dives
If we are showing the setpoint and sensor pO2 we need the space.

Signed-off-by: Joakim Bygdell <j.bygdell@gmail.com>
2017-02-05 12:20:33 -08:00
Joakim Bygdell
11ccadbab5 MOBILE: Reposition objects in the profile
Add the tankbar to the profile and change the relative positions of the depth
and temperature curves to minimize overlap.

Signed-off-by: Joakim Bygdell <j.bygdell@gmail.com>
2017-02-05 11:59:47 -08:00
Robert C. Helling
2516ae7e5f Let cylinderid = -1 mean same gas as before
It's not too clever to give 0 a special meaning (as here:
use same gas as for previous leg) when 0 is a legitimate
value.

This should solve Willem's gas disappearance problem when
reediting a dive in the planner.

Signed-off-by: Robert C. Helling <helling@atdotde.de>
2017-02-04 07:09:35 -08:00
Dirk Hohndel
f5a4838519 Fix dive visual editor being too quick to rescale time
When moving the last handle of a dive (in the planner, in dive add, or
when editing a dive), we rescaled the time axis whenever our idea of the
maximum duration that we should show changed. That lead to the odd
situation that you couldn't get to certain dive durations with the
visual editor (e.g. 64 minutes) because just as you approach that time
the scale changes and the dive duration jumps past the desired value.

Fixes issue #174

Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
2017-01-28 21:04:50 -08:00
Joakim Bygdell
dd2791fa1e Fix tankbar offset at gas switch event
When painting the tankbar the function triggers on change in cylinder index,
as a result the new gascolour are changed at the next sample time point.
On a divecomputer with a reasonable fast sample rate the 2-3s offset are hardly
noticable, especially on a longer dive.
For divecomputers with slow sample rate the 10-30s offset are clearly visible.

This is fixed by start painting the new gascolour at the time point of the switch event rather than the time point of the next sample.

Signed-off-by: Joakim Bygdell <j.bygdell@gmail.com>
2017-01-21 06:07:31 -08:00
Joakim Bygdell
f7cecf506f Don't let the tankbar overlap the tissue heatmap
Shift the position of the tankbar to prevent it from overlapping the tissue heatmap

Signed-off-by: Joakim Bygdell <j.bygdell@gmail.com>
2017-01-21 06:07:31 -08:00
Robert C. Helling
fedadc65db Prevent the heatmap form overlapping at the ends
...by making the pen start at its first position rather
than first position minus half width.

Sorry for my first attempt to solve this in a totally
differen (read: wrong) way.

Signed-off-by: Robert C. Helling <helling@atdotde.de>
2017-01-15 11:37:26 -08:00
Robert C. Helling
bb4bf639c3 Fix deco_mode confusion
We have two prefernces determining the deco_mode (BUEHLMANN vs VPMB
vs RECREATIONAL): One for the planner (deco_mode) and one for
displaying dives (display_deco_mode). The former is set in the planner
settings while the latter is set in the preferences.

This patch clears up a confusion which of the two to use by introducing
a helper function that selects the correct variable.

Signed-off-by: Robert C. Helling <helling@atdotde.de>
2017-01-06 20:43:23 -08:00
Tomaz Canabrava
37e3e7e69a Deco mode for plannining is not deco mode for showing
We had (in the wrong place, imo) a new feature that
should differentiate the different deco_modes, you could
plan your dive in buelhman and see it in vpm-b, for instance
but both of them accessed the same pref.

Signed-off-by: Tomaz Canabrava <tcanabrava@kde.org>
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
2016-11-01 09:41:17 -07:00
Tomaz Canabrava
c110b4a238 More preference handling fixes
Remove a few uneeded lines and add more loading code for
the preferences.

Signed-off-by: Tomaz Canabrava <tcanabrava@kde.org>
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
2016-11-01 09:40:43 -07:00
Tomaz Canabrava
27d1385c65 Use the new preferences object to set the preferences
Signed-off-by: Tomaz Canabrava <tcanabrava@kde.org>
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
2016-11-01 09:40:06 -07:00
Rick Walsh
a2d6bcf23f ToolTipItem: only show gf line in pressure graph when using Buhlmann model
Signed-off-by: Rick Walsh <rickmwalsh@gmail.com>
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
2016-10-27 20:36:08 -07:00
Rick Walsh
d689390140 Heatmap: Show more yellow
Stretch out the yellow zone of the HSV scale, because the yellow band of the
true scale appears narrow.

Signed-off-by: Rick Walsh <rickmwalsh@gmail.com>
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
2016-10-20 21:14:27 -07:00
Rick Walsh
fd46167ae0 Heatmap: Color undersaturated values relative to inert gas pressure
Color "undersaturated" values relative to inert gas pressure of gas being
breathed, rather than relative to inert gas pressure of air.
Also change slightly the point at which bright green (hue = 120 deg) from 10%
of M value to 0% of M value (=ambient pressure).
Other than the slight shift in lower bound of the green-red scale, this does
not affect the colors of the tissues with inert gas pressure greater than
ambient pressure, which are relative to the Buhlmann M value.

Signed-off-by: Rick Walsh <rickmwalsh@gmail.com>
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
2016-10-20 21:14:19 -07:00
Rick Walsh
a67d3f0e30 Heatmap: Draw lines between data points rather than big dots
By drawing oversize dots for each data point, dots were overlapping such that
the change in tissue presssure wasn't displayed at the right time - typically
out by 1-2 minutes, depending on dive duration.

Drawing a line between discrete points, the data points don't overlap and
change in tissue pressure is displayed at the right time.

Signed-off-by: Rick Walsh <rickmwalsh@gmail.com>
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
2016-10-20 21:11:15 -07:00
Robert C. Helling
87ced29e09 Initialize tooltip tissue pixmap properly
...otherwise we show garbage before the mouse enters the
profile for the first time.

Signed-off-by: Robert C. Helling <helling@atdotde.de>
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
2016-10-03 07:58:43 -07:00
Dirk Hohndel
c907efb22e Correctly hook up visibility toggle for tissue heat map
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
2016-09-24 12:50:19 -07:00