Update to match Xcode command-line-tools SDKs from 10.X to 16.X
Signed-off-by: Doug Junkins <douglas.junkins@gmail.com>
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
For some reason (use of OpenGL?) with Qt6 these modes fail for me.
Needless to say, I consider this API change a very unfriendly
behavior.
Replace these modes by DrawTriangleStrip and DrawLineStrip.
Signed-off-by: Berthold Stoeger <bstoeger@mail.tuwien.ac.at>
This include prevented the statistics from loading for me on Qt6.
And it appears to be unnecessary.
Signed-off-by: Berthold Stoeger <bstoeger@mail.tuwien.ac.at>
The code that calculates the bounds of the value axis was broken
when all items had the same value. In that case, increase the shown
range explicitly. It doesn't really matter how much the range
is increased, because all items will be at the center of the graph.
Also, don't overwrite the "decimal" value of the class. That was
just weird.
Fixes#3544.
Signed-off-by: Berthold Stoeger <bstoeger@mail.tuwien.ac.at>
When loading a git repository, dive sites where loaded into the
global dive site table, not the local table. Apparently, nobody
ever tried to import a git repository into an existing divelog
(as opposed to opening it in the application). Because that would
have probably given funky results.
Remove this access of a global variable.
Signed-off-by: Berthold Stoeger <bstoeger@mail.tuwien.ac.at>
-build-with-qt6 did not work for me, because the flag is
ignored when selecting the qmake executable. It would find
the system-wide qmake executable, which is Qt5 and then
decide to build with Qt5.
When the flag is set, try to search for a Qt6 version of
qmake first. On Ubuntu based distros this seems to be
qmake6
Signed-off-by: Berthold Stoeger <bstoeger@mail.tuwien.ac.at>
When collecting the data for the infobox, we have
already computed the current partial pressures of the
breathing gas taking into accoutn the divemode. Use
those rather than fractions (which for CCR mode are
those of diluent) to compute the gas density.
Reported-by: Pietro Tranquillini <p.tranquillini@gmail.com>
Signed-off-by: Robert C. Helling <helling@atdotde.de>
- uwatec smart: allow bigger BLE packets
- Garmin: attempt to parse big endian FIT files from the Garmin website
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
Most of these declared non existing functions or pointers.
One [get_gas_idx()] was only used in one source file and
doesn't have to be globally accessible
Signed-off-by: Berthold Stoeger <bstoeger@mail.tuwien.ac.at>
Search the index of an item in a container. Compare by
equality or a lambda. The lack of these have annoyed me for a
long time. Return the index of the first found element or
-1 if no element found.
Currently, only supports random-access operators. Might be
trivially changed for forward iterators.
Signed-off-by: Berthold Stoeger <bstoeger@mail.tuwien.ac.at>
When switching from "empty mode" (i.e. the subsurface logo is shown,
because no dive is selected), the profile is first shown by switching
to the appropriate tab and then plotted. However, the showing might
lead to a resize event and then to a crash with owing to stale dive
data. Therefore, reverse that.
Note that I never could reproduce that.
Reported-by: Robert C. Helling <helling@atdotde.de>
Signed-off-by: Berthold Stoeger <bstoeger@mail.tuwien.ac.at>
When the profile was to small, it would switch into empty state
and clear the plot info.
On resize events, the plot info is not recalculated.
This means that when making the profile extremely small and
then bigger, nothing is shown.
This may also happen on startup. The profile is rendered into
a 0x0 widget and then gets a resize event.
Therefore, remember when the profile is empty and force a
recalculation of the plot info.
Signed-off-by: Berthold Stoeger <bstoeger@mail.tuwien.ac.at>
The chances that their are still users of the old thumbnail
format (i.e. all thumbnails saved in the hash file) are basically
0. If there are they will just get their thumbnails rebuilt
when opening the individual dives.
Signed-off-by: Berthold Stoeger <bstoeger@mail.tuwien.ac.at>
There were a number of classical "for (i = 0; i < size; ++i)"
loops. Replace them either by plain range based loops if the index
is not used or by enumerated_range() loops.
Signed-off-by: Berthold Stoeger <bstoeger@mail.tuwien.ac.at>
This source file was looping over descriptors in a classical
"for (int i = 0; i < size; ++i)" loop.
However, the index is not really used, except for fetching the
actual elements.
Replace by range-based for loops. This prevents the potential
error of using the wrong size.
Signed-off-by: Berthold Stoeger <bstoeger@mail.tuwien.ac.at>
In the printing-template code, we loop through a vector and
then determine the index of the current element by searching
the vector. This irks me.
Since looping over a collection with an index is a rather
common theme, implement an enumerating iterator that can
be used as in:
for (auto [idx, item]: enumerated_range(v)) {
...
}
For now, use it for the above vexing case. Convert other
iterations of this theme later.
Signed-off-by: Berthold Stoeger <bstoeger@mail.tuwien.ac.at>
The moveInVector() function was defined in qthelper.h, even
though it has nothing to do with Qt. Therefore, move it into
its own header.
Morover, since it is a very low-level function, use snake_case.
And rename it to move_in_range(), because it does not only
work on vectors, but any range with random-access iterators.
Signed-off-by: Berthold Stoeger <bstoeger@mail.tuwien.ac.at>
For reasons of symmetry (there is a is_manually_added_dc()
function), create a make_manually_added_dc() function.
Signed-off-by: Berthold Stoeger <bstoeger@mail.tuwien.ac.at>
This causes UI confusion. Notably we go into edit mode and
reduce the number of samples, leading to loss of information.
If someone really manually adds a dive with more than 50
samples, they should still be able to explicitly open the
dive in the planner.
Signed-off-by: Berthold Stoeger <bstoeger@mail.tuwien.ac.at>
The calculation of the range was broken, it resulted in
a to-value smaller than the from-value, owing to a
sign-mismatch.
Signed-off-by: Berthold Stoeger <bstoeger@mail.tuwien.ac.at>
We must add one more entries than there are days, because the
entries describe the values between histograms.
The root cause of the problem here is that a histogram axis
is misused for a continuous day-axis.
Signed-off-by: Berthold Stoeger <bstoeger@mail.tuwien.ac.at>
Scatter items of selected dives were shown in blue when
changing to scatter mode. They should be yellow from the
start, not only when hovering over them.
Signed-off-by: Berthold Stoeger <bstoeger@mail.tuwien.ac.at>
This got broken in commit 7417f865cd ("cleanup: un-singletonize
ShiftTimesDialog") and no one ever noticed.
We need to intitialize the when variable and set up the initial texts in
order for the time shift dialog to show the correct information. Doing
this in the ButtonClicked member (right before the dialog is destroyed)
makes absolutely no sense.
Fixes#3535
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
This rarely gets seen / looked at, but it can help make it easier
to understand what a user was doing when trying to restore dives
that were inadvertantly deleted.
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
Embarrassingly, commit 8c644547fb ("mobile: fix reading of cache dir")
dropped updates to libdivecomputer which went unnoticed for quite a
while. This brings us back to the correct SHA.
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
The dive-site editing can be reached from two states: from the
dive view and the dive list view. It always jumped back to
the dive view.
Therefore, remember the state. Use a stack-like structure, so
that the feature can be used for the dive-site view as well.
This is a bit inconsistent, because for example the statistics
view does not remember the previous state and allows a direct
jump to a different state. That should be fixed at some point.
Signed-off-by: Berthold Stoeger <bstoeger@mail.tuwien.ac.at>
This used to be one of the tab-widgets, which was illogical
and caused confusion. Notably, erroneously clicking on the
tab header led to a reset of the dive selection.
Signed-off-by: Berthold Stoeger <bstoeger@mail.tuwien.ac.at>
fixup_dc_sample_sensors() would make sure that any pressure sensor
indexes were in range of the cylinders by just clearing the pressure
data if the sensor index was larger than the number of cylinders in the
dive.
That certainly makes the sensor index data consistent, but at the cost
of just dropping the sensor data entirely.
Dirk had some cases of odd sensor data (probably because of an older
version of subsurface, but possibly due to removing cylinders manually
or because of oddities with the downloader for the Atomic Aquatics
Cobalt dive computer he used), and when re-saving the dive, the pressure
data would magically just get removed due to this.
So rewrite the sensor data fixup to strive very hard to avoid throwing
pressure sensor data away. The simplest way to do that is to just add
the required number of cylinders, and then people can fix up their dives
manually by remapping the sensor data.
This whole "we clear the pressure data" was at least partly hidden by
two things:
(1) in the git save format, we don't rewrite dives unless you've
changed the dive some way, so old dives stay around with old data
in the save until explicitly changed.
(2) if you had multiple dive computers, and one dive computer does not
have any pressure data but another one does, our profile will use
that "other" dive computer pressure data (because often times you
might have only one dive computer that is air integrated, but you
still want to see the tank pressure when you look at other dive
computers - or you have one dive computer give pressure data for
your deco bottle, and another for your travel gas etc).
So those two facts hid the reality that we had actually cleared the tank
sensor data for Dirk's dive with the Atomic Aquatics dive computer,
because we'd still see pressure data in the profile, and the git data
would still be the old one.
Until Dirk renumbered his dives, and the data was rewritten.
Signed-off-by: Linus Torvalds <torvalds@linux-foundation.org>
It returned a 'uint8_t', which clashes pretty badly with NO_SENSOR being
-1, and turned it into 255. That then ended up historically working,
because before commit 0c84f369c3 ("core: use int16_t for sensor-id")
we actually did that everywhere:
#define NO_SENSOR ((uint8_t)-1)
...
uint8_t sensor[MAX_SENSORS];
but that was changed to
#define NO_SENSOR -1
...
int16_t sensor[MAX_SENSORS];
and this helper type became wrong.
Just make it return 'int', avoiding any type narrowing issues.