correct SLOT was sec_bottomsac(double), which
is not reported as an error.
correct to set_bottomsac(double)
Signed-off-by: Jan Iversen <jan@casacondor.com>
QSignalMapper gives a warning that it is depreciated, and the
doc. states that using a lambda function is more efficient.
Replace use of QSignalMapper.
Signed-off-by: Jan Iversen <jan@casacondor.com>
QSignalMapper had a parameter convert problem, when mapping to
set_deco_mode in plannerShared.
Use lambda function in connect to avoid parameter convert problem.
Signed-off-by: Jan Iversen <jan@casacondor.com>
There were two cases that were handled incorrectly:
- if the user hasn't entered a salinity, obviously there shouldn't be a warning
- if this is a manually entered dive, there is no salinity downloaded from a
dive computer, so equally, no warning
Suggested-by: willemferguson <willemferguson@zoology.up.ac.za>
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
We need to show this whenever the value in the dive (which could have been
entered by the user some other time) doesn't correspond to the value in the DC.
This, btw, will point out to the user if different DCs have different values.
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
We were royally confused when we didn't know the salinity value (e.g., if the
dive computer didn't provide that information). We somehow treated this as the
same as wanting to use the salinity information in the dive computer. Which
makes no sense.
While cleaning this up, this also adds the textual representations of the water
types as a string list that corresponds to the enum values that we use - this
way it's easier to stay consistent.
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
Added code for string translation.
Added code to improve UI on Windows.
Added some comments to make the code more understandable.
Enable salinity combobox for manually entered dives
Signed-off-by: willemferguson <willemferguson@zoology.up.ac.za>
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
The user may modify the salinity by selecting a water type from the combobox.
The new datum does not replace the existing salinity value but is stored in a
separate variable within the dive structure. If the dc-based salinity is
overwritten, there is an exclamation mark next to the modified salinity value
to indicate that the salinity has been overwritten. The dc-derived salinity can
always be recovered by selecting the "use dc" option in the combobox.
Signed-off-by: willemferguson <willemferguson@zoology.up.ac.za>
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
Create a checkbox in the Preferences: General screen that enables or disables
editing of the salinity data. This preference is saved with all the other
preferences.
Signed-off-by: willemferguson <willemferguson@zoology.up.ac.za>
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
Commit dbb504 tried to prevent an uninitialized dc pointer
from being dereferenced. But I screwed up the logic always
setting the event pointer to NULL. This fixes this error.
Reported-by: willemferguson@zoology.up.ac.za
Signed-off-by: Robert C. Helling <helling@atdotde.de>
When changing METERS <-> FEET, the text change automatically
between "m/min" and "ft/min".
Signed-off-by: Jan Iversen <jan@casacondor.com>
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
This allows to update plannermodel etc. and thus avoiding a restart when
changing units for length.
Signed-off-by: Jan Iversen <jan@casacondor.com>
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
When using the string setters, the original signal should still be emitted.
Change to call original setter in string setter.
Signed-off-by: Jan Iversen <jan@casacondor.com>
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
When changing between METRICS <-> IMPERIAL, all type signals are emitted.
This may cause double sending of some signals, but all signals will be emitted
at least once.
Signed-off-by: jan Iversen <jan@casacondor.com>
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
When switching between imperial/metric it is important to change the single
measurements as well (e.g. METER <-> FEET).
Signed-off-by: Jan Iversen <jan@casacondor.com>
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
All unit functions have a string version and a normal version, except
unit_system.
Make a non string version of unit_system.
Signed-off-by: Jan Iversen <jan@casacondor.com>
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
Do not use a.set_b(value); it works, but it introduces yet another way of using
the QML/C++ interface, furthermore the function might not be called set_b in
some future, which is the reason the function is define in Q_PROPERTY
Use a.b = value, that respects Q_PROPERTY, and is slightly more performant,
most importantly it's like all the other settings so noone starts wondering why
this is special.
Signed-off-by: Jan Iversen <jan@casacondor.com>
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
Set the text of ascent/descent rates.
This shows the correct speed units when the user switches between metric and imperial.
Signed-off-by: Jan Iversen <jan@casacondor.com>
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
As much as I hate having passwords exposed through the source code,
since GitHub wisely prevents reading secrets in pull requests, there
isn't really a sane way to have this use confidential credentials.
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
While this appears to work fine when tested individually, when running
as part of the GitHub actions it causes random failures. This needs to
be rethought.
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
This is a bit more convoluted to do inside of the Ubuntu 19.10 container, but
at least for Ubuntu 14.04 and for Mac this will be an improvement.
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
TestGitStorage is used in all test runs, which results in occasional errors
because two test runs step on each other. This allows us to use different
accounts in different runs.
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
It's silly to set up the URL and email in almost every function. Instead do it
once at the start and reuse that information.
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
but the proper way, as a direct check on
PrefCloudStorage.
This secures PrefCloudStorage is only tested once and not
n times. As a sideeffect it saves typing and control.
Signed-off-by: Jan Iversen <jan@casacondor.com>
- Several fixes for Mares divecomputer BLE communication
- Fix the Aeris Manta memory layout
- Add support for the Oceanic Pro Plus 4
- Strip the source directory from file names
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
(planning is excluded, due to not finished UI).
Connect all spinboxes with plannerShared.
This change allows live testing and compare with the desktop version.
Signed-off-by: Jan Iversen <jan@casacondor.com>
(planning is excluded, due to not finished UI).
Connect all checkboxes with plannerShared.
This change allows live testing and compare with the desktop version.
Signed-off-by: Jan Iversen <jan@casacondor.com>
The getter returns alwayes in m/1000, making the calculations
identical, independent if the system is in Metric or Imperial units.
Correct getter test cases.
Signed-off-by: Jan Iversen <jan@casacondor.com>
When unit system Imperial is properly activated, these test cases
have wrong values, and thus fail.
Use correct values.
Signed-off-by: Jan Iversen <jan@casacondor.com>
reactivate deco2 test case, after problem is solved in plannerShared.
Also add a commit on bottompo2/decopo2 in imperial mode, that do not
use PSI as expected.
Signed-off-by: Jan Iversen <jan@casacondor.com>
The default behavior of parse_file() is different between a desktop build
and a mobile build. This makes parse_file() always assume that it's ok to
connect to the cloud.
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>