This reverts commit adaeb506b7.
commit a8e8d56ec0 ("Tweak cylinder equipment tooltips") does a much
better job allowing the user to know the true volume of the cylinder
(given the gas entered) and clutters the UI a lot less.
While playing around with the current subsurface, I realized that while we
give the gas volume and Z factor for the beginning/end pressures in the
newly added tooltips, there is no way to actually see that same
information for the working pressure.
So if you have filled in cylinder type information, but don't have any
actual gas usage information, there will be no cylinder tooltips at all.
But you might still want to know what the actual volume for a particular
cylinder is, and what the Z value for that working pressure is.
So this tweaks the tool-tips a bit.
When mousing over the pressure fields (ie "working pressure", "start" and
"end"), it now always gives the cylinder gas volume and Z factor for that
pressure, so for example on an AL72 that has a working pressure of 3000
psi and that contains air the tooltip will say:
69 cuft, Z=1.040
when you mouse over the working pressure field (that's obviously with
imperial units, in metric you'll see liters of gas).
When mousing over the type/size field, it gives the used gas amounts, ie
something like this:
37 cuft (82 cuft -> 45 cuft)
but if the cylinder doesn't have starting/ending pressures (and thus no
used gas information), this patch will make subsurface show the working
pressure data instead, so that you at least get something.
This all seems more useful than what my first version gave.
NOTE! This makes commit adaeb506b7 ("Show both the nominal and "real"
size for an imperial cylinder") kind of pointless. You now see the real
size in the tooltip when you mouse over the size, and now it actually
works both for imperial and metric people, so the tooltip is in many ways
the better model.
Signed-off-by: Linus Torvalds <torvalds@linux-foundation.org>
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
Modify formluas for gas use to take into account the
compressibility correction for real gases. This introduces
also the inverse formula to compute the pressure for a given
amount of gas.
Signed-off-by: Robert C. Helling <helling@atdotde.de>
...by making the pen start at its first position rather
than first position minus half width.
Sorry for my first attempt to solve this in a totally
differen (read: wrong) way.
Signed-off-by: Robert C. Helling <helling@atdotde.de>
Our attempt to skip any white space after the comma causes an ASSERT (strangely
only on Macs).
This closes#158
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
The section for fb export missed one crucial sentence. Added it.
Signed-off-by: Willem Ferguson <willemferguson@zoology.up.ac.za>
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
Replace image reflecting dive export formats to show the current options.
Signed-off-by: Willem Ferguson <willemferguson@zoology.up.ac.za>
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
Generate text for:
1) Splitting a dive from the dive list context menu
2) Importing photos from the Internet
Signed-off-by: Willem Ferguson <willemferguson@zoology.up.ac.za>
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
This adds tooltips for the equipment tab for each cylinder, showing the
amount of gas used.
When you mouse over the size and working pressure fields, the tooltip will
show the amount of gas used (along with start and end gas volumes). And
when you mouse over the start and end pressures, it will show the start
and end gas volumes, and the Z factor used.
I started doing this because of the gas volume questions in the last day
or two (and a few from a few weeks ago). When even Robert Helling starts
wondering about the effects of compressibility on the SAC calculation, our
numbers are clearly too opaque.
With these tooltips, at least you can see what went into the used gas
calculations, instead of having to add debugging options to print out Z
factors.
[ This patch also adds a "rint()" to get the rounding right in the
gas_volume() function. Although rounding to the nearst milliliter
really doesn't matter, it's the right thing to do after doing FP
calculations ;^]
Signed-off-by: Linus Torvalds <torvalds@linux-foundation.org>
This adds support for notifying Ostc 4 users about new firmwares when
they download dives from their computers, gives them the option to
trigger the upgrade flow.
Signed-off-by: Anton Lundin <glance@acc.umu.se>
Instead of creating the individual parsers, and keeping track of their
arguments, this just uses the "new" dc_parser_new2 function ment for
buffer parsing.
Signed-off-by: Anton Lundin <glance@acc.umu.se>
This removes our own declaration of dc_descriptor_t and all our accesses
to its internals, and switches to use the libdivecomputer functions to
access those instead.
Signed-off-by: Anton Lundin <glance@acc.umu.se>
Also fix two images broken links, fix a trailing white space an fixes
a text block formatting.
Signed-off-by: Salvador Cuñat <salvador.cunat@gmail.com>
Update:
1) Text dealing with SmartTrak import. Move text, some corrections,
add image.
2) Text dealing with command-line arguments.
A few other small changes.
Signed-off-by: Willem Ferguson <willemferguson@zoology.up.ac.za>
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
By using SettingsObjectWrapper, the planner settings can be saved and restored
correctly
Signed-off-by: Rick Walsh <rickmwalsh@gmail.com>
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
This is to avoid confusion with planner.display_deco_mode.
When accessing the "current deco mode" use the decoMode()
helper function.
Signed-off-by: Robert C. Helling <helling@atdotde.de>
We have two prefernces determining the deco_mode (BUEHLMANN vs VPMB
vs RECREATIONAL): One for the planner (deco_mode) and one for
displaying dives (display_deco_mode). The former is set in the planner
settings while the latter is set in the preferences.
This patch clears up a confusion which of the two to use by introducing
a helper function that selects the correct variable.
Signed-off-by: Robert C. Helling <helling@atdotde.de>