When the file system of the Zurich gets full, the only way to continue to
download from it, is to disconnect and reconnect the dive computer (which
resets the FAT file system that it emulates to 'empty').
This solution is rather hacky and weird because it does a hard count down in a
busy loop, but given the narrow use case, this may be acceptable.
This also adds support for the UEMIS_DIVE_OFFSET environment variable that
allows the user to skip dives on the device.
[refactored by Dirk Hohndel]
Signed-off-by: Oliver Schwaneberg <oliver.schwaneberg@gmail.com>
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
This was a user request: Sort bar charts by height of the bars.
Obviously, this can only work for categorical charts, not for
histograms.
The UI is a break from the old concept: the sorting is chosen
based on the chart, whereas for the rest of the features, the
viable charts are presented based on the binning, etc.
I found it confusing to have the possible charts be selected
based on sorting. I.e. if a non-bin sort mode is selected,
the histogram charts disappear. On the flip side, this would
be more consistent. We can change it later.
For value-based bar charts, there are three sort modes: by
bin, by count (i.e. number of dives in that bar) and by
value (i.e. length of the bar). This hopefully satisfies all
needs.
Signed-off-by: Berthold Stoeger <bstoeger@mail.tuwien.ac.at>
The undo commands for depth and duration editing cleared
the samples of the dive computer. They relied on the profile
automatically creating a fake profile. However, at some point
that code got removed. Therefore, do it explicitly in the undo
command.
Signed-off-by: Berthold Stoeger <bstoeger@mail.tuwien.ac.at>
CCRs are different. It does not make sense to compute
a depth dependent SAC. You could compute the rate of O2
consumption but even that is likely wrong (as O2 in the
diluent would enter that as well), so simply don't attempt
it.
Signed-off-by: Robert C. Helling <helling@atdotde.de>
Air is a special gas that does not contain oxygen according
to gasmix.o2.fraction. If you want to use the fo2, you
need to use get_o2() to treat this special case correctly.
This fixes a bug when setting the MND of a gas containing
21% oxygen when o2 is considered not narcotic.
Reported-by: Christoph Gruen <gruen.christoph@gmail.com>
Signed-off-by: Robert C. Helling <helling@atdotde.de>
For dives with mixed divemode, one needs to check sample.setpoint
to figure out if the segment is an OC segment and the po2 needs
to be computed from the gasmix and ambient pressure.
This fixes#3310
Signed-off-by: Robert C. Helling <helling@atdotde.de>
We already showed the tags, but we didn't allow the user to edit them.
This tries hard not to create inconsistent or illogical tags by trimming
white space and being careful with how the tags are added.
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
If the last displayed dive had events, those DiveEventItems had slots connected
that would update those icons if things changed. When closing the dive log and
switching to a different one, those slots were still called and would then access
freed memory (the event structure from that old dive that is long gone by then).
This code explicitly deletes those DiveEventItems which also removes those signal
slot connections.
Fixes#3305
Sugested-by: Berthold Stoeger <bstoeger@mail.tuwien.ac.at>
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
If we download a first dive computer and add a dive site to the dive (by
setting a location name for example), and then download from another
dive computer that provides us with GPS data, we should keep the
existing dive site information, but add the GPS data from the freshly
downloaded dive computer.
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
The changes in commit 4daf687876 ("profile: remove [disable|enable]Shortcuts()
signals") resulted in us no longer enabling the shortcuts on the desktop (at
least on macOS where I debugged this). This placement of the call feels like a
bit of overkill, but at least it shouldn't be wrong.
Fixes#3293
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
The DiveEventItem had an internal copy of the event. It passed
that copy to the undo-machinery, which of course didn't work.
Simply keep a pointer to the event. All changes to a dive no
pass via the undo-machinery, which causes a reload of the profile,
so this should be safe.
Reported-by: Willem Ferguson <willemferguson@zoology.up.ac.za>
Signed-off-by: Berthold Stoeger <bstoeger@mail.tuwien.ac.at>
the last manually entered waypoint but consider the
possibility that it should first top where we are
before the next stop depth has cleared.
Reported-by: David Carron
Signed-off-by: Robert C. Helling <helling@atdotde.de>
The TeX exports may hang the UI for a long time.
Show a progress-dialog that is updated after every exported dive
and allows the user to cancel the export.
This is pretty lame, because it is synchronous (export still runs
in UI thread) and therefore the UI still is sluggish. But it
is an improvement.
Since the TeX-exporting code is in a shared directory (desktop and
mobile), this uses a slim interface class. Mobile does not
yet use TeX export, but you never know. Better than #ifdefs
sprinkled all around, I reckon.
Signed-off-by: Berthold Stoeger <bstoeger@mail.tuwien.ac.at>
The font-size in printed profiles is based on the size of the profile
in the main window. This makes no sense. Why should changing the
window size change the font-size on printouts?
Matter of fact, when making shrinking the height of the window to
its minimum, comical printouts are obtained (font way too big).
Therefore use an arbitrary rule: Say that profiles 600 pixels high
look reasonable and then scale up to the actual size on the printout.
This may need some tweaking for high-DPI mode. But that seems not
to be supported on desktop anyway?
Signed-off-by: Berthold Stoeger <bstoeger@mail.tuwien.ac.at>
Both the calculations for CNS and OTU did not take
into account the pO2 drop when using a PSCR. Furthermore,
there was some unit confusion due to not using internal
units.
Reported-by: arosl
Signed-off-by: Robert C. Helling <helling@atdotde.de>
This feels much more responsive to various screen widths to me.
Instead of a fixed grid this is now a Flow that is tries to make much
better use of the space available on the user's device. It's not always
perfect, but to me at least a massive improvement.
The commit is almost unreadable because of the re-indentation and the
move of a block of fields to earlier in the form (as that made it much
easier to flow everything). But with show -w you can get a better idea.
We have a Flow around all the fields, we pair each label with the
corresponding input field, and then have a few additional Flows to
ensure that the cylinders always start in the first column.
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
Adds fields to the advanced preferences page to modify GFLow and GFHigh for
the Buhlmann decompression model for calculating ceilings. Updated preferences
code to set the Buhlmann parameters in core/deco.c when the GF prefs are
updated.
Signed-off-by: Doug Junkins <douglas.junkins@gmail.com>
First, the time zone adjustment was wrong - this as written could only
ever have worked in UTC or by pure chance.
Second, the order of alerting the UI of the availability of a GPS fix
was also incorrect creating a race between the UI and our data
structures.
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
When setting a CCR setpoint, the profile code(!) would turn
the dive into a CCR dive. Not only should the display layer
not alter dives, this also means that the action is not
undoable.
Move that to the appropriate undo command, where it makes
more sense, but obviously also makes things more complicated.
Signed-off-by: Berthold Stoeger <bstoeger@mail.tuwien.ac.at>
The AddWeight, RemoveWeight, EditWeight and ReplanDive
commands were missing invalidate_dive_cache() calls.
Add them to ensure that the dives are written to git
logs on save.
Fixes#3150
Reported-by: Peter Zaal <peter.zaal@gmail.com>
Signed-off-by: Berthold Stoeger <bstoeger@mail.tuwien.ac.at>
This also includes the already merged statistics for mobile.
All of this still needs to be added to the user manual.
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
A user complained about the default cylinders list. Provide
a preferences option to turn this off.
When changing the preferences, the tank-info model will be
completely rebuilt. Currently, this is a bit crude as this
will be done for any preferences change.
Suggested-by: Adolph Weidanz <weidanz.adolph@gmail.com>
Signed-off-by: Berthold Stoeger <bstoeger@mail.tuwien.ac.at>
These are static functions, they cannot be used as a method on an object to
construct that object.
commit aa5f2e7c73 ("cleanup: replace deprecated sprintf()/vsprintf() calls")
introduced this bug in an ill-advised attempt to deal with a deprecation
warning.
This caused us to not print GPS coordinates in the UI.
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
When breathing pure oxygen and considering it not
narcotic, there is not maximal narcotic depth and
the formula divides by zero. So better, handle this
case separately.
Fixes#3080
Signed-off-by: Robert C. Helling <helling@atdotde.de>
The scope confusion between s (the for loop variable) and s (the function
argument) caused a crash in the s.split() on Windows.
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
Instead of modifying the device table directly, call the undo
commands. Moreover, don't keep our own copy in the mode - show
the original version. Connect to the appropriate signals.
This means that the calls from the DiveComputerManagement
dialog have to be removed, since this mode of editing is
not supported. The whole dialog will be removed in a future
commit.
Signed-off-by: Berthold Stoeger <bstoeger@mail.tuwien.ac.at>
The interaction of Qt's drag & drop with GroupedLineEdit was
exceedingly weird. The user was able to scroll the viewport
making the text invisible.
This implements a very primitive alternative drag & drop
functionality: dropped text is regarged as a distinct tag.
This means that it is not possible to modify existing tags
by dropping in the middle of them. Arguably, this might even
be better than arbitrary drag & drop. But even if not perfect,
this fixes a very nasty UI behavior.
Signed-off-by: Berthold Stoeger <bstoeger@mail.tuwien.ac.at>
A few years ago the upstream for libhidapi changed - it became part of the
libusb GitHub org. Switching to the latest version appears to fix some odd
problems with talking to the Suunto Eon Steele/Core dive computers on macOS (at
least I can no longer reproduce the problem after switching to the current
version).
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
When merging cylinders pressures derived from samples were taken
as maximum of the start and minimum of the end pressure, which
makes sense, since we believe that this is the same cylinder.
However, for manually entered pressures, this was not done.
Moreover, when one dive had manual pressures and the other only
pressure from samples, the manual pressure was taken. However,
that could have been the wrong one, for example if the end
pressure was manually set for the cylinder of the first part of
the dive, but not the last.
Therefore, improve merging of manuall set pressures in two ways:
1) use maximum/minimum for start/end pressure
2) if the pressure of one cylinder was manually set, but not for
the other, complete with the sample pressure (if that exists).
Fixes#2884.
Signed-off-by: Berthold Stoeger <bstoeger@mail.tuwien.ac.at>
The UI only allowed adding dives to trips above or below the
current dive (and even that is buggy). This is a strange
restriction, since trips are designed to be non-contiguous.
Allow adding dives to any trip using the new trip selection
dialog. The undo-command is already there, so only little
code to write.
This feature was requested on the mailing list.
Signed-off-by: Berthold Stoeger <bstoeger@mail.tuwien.ac.at>
In the dive list we have horrible code, which intercepts all events
to save the selection before/after the event. This was necessary
because we couldn't get Qt's selection data flow under control.
This means intercepting all events that can change the selection.
The page-up, page-down, home and end keys were forgotten. Add these
cases.
Fixes#2957.
Signed-off-by: Berthold Stoeger <bstoeger@mail.tuwien.ac.at>
The cylinder model is used both in the planner and the
equipment tab. We have three preferences for the pO2 that
is used to compute MOD: In the planner, there is one for
the bottom part of the dive and another one for deco.
Those are set in the planenr UI. There is another value,
controlled in the Tec Prefernces. That one should be
used in the equipment tab rather than the one from
the planner.
Fixes#2984
Signed-off-by: Robert C. Helling <helling@atdotde.de>
If the dive timestamp changes, the dive could move in the dive list. But the
current dive actually doesn't change (it's still the same dive, right?). Yet
we need to update the dive list as well as the shown dive (especially if this
is after adding a dive, which is first inserted with the current time and then
updated with whatever the user enters).
Fixes: #2971
Suggested-by: Berthold Stoeger <bstoeger@mail.tuwien.ac.at>
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
When an undo command selected invisible dives, a current dive outside
of the list of selected dives was chosen. This could have the very
unfortunate effect that the current dive was set, though not selected.
From an UI point of view this meant that the dive was displayed, but
edits would not be registered.
Change the setClosestCurrentDive function to select the current dive.
Signed-off-by: Berthold Stoeger <bstoeger@mail.tuwien.ac.at>
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
At some time, when introducing the global reset signal the filter
stopped being reloaded when loading a new log. This leads to very
strange UI behavior: dives disappear when editing fields unrelated
to the filter.
Therefore, when reloading the model, reset the filter. One might
argue whether this is the correct place. On the other hand, we
might even make the filter a sub-object of the dive-list model.
Let's think about this.
Partially solves #2961
Signed-off-by: Berthold Stoeger <bstoeger@mail.tuwien.ac.at>
ExifTools (and probably other meta-data editors) modifies the
mvhd creation date, but leaves the individual creation dates
in the tracks unchanged. Therefore, use the mvhd atom.
Reported-by: Eric Tanguy <erictanguy2@orange.fr>
Signed-off-by: Berthold Stoeger <bstoeger@mail.tuwien.ac.at>
When importing from other software, it happens that weights are imported
without their type. When the user changes the type, the imported weight
is overwritten, which is not exactly a friendly behavior.
On the other hand, when changing the type after creation of a weight
entry, it is preferrable to set a default weight. This is convenient
for people who commonly use the same weight.
As a compromise, set the default weight only if it was unset. We
recognize this by a weight value of 0 g.
Fixes#2938
Signed-off-by: Berthold Stoeger <bstoeger@mail.tuwien.ac.at>
User request: when entering a cylinder type, do a substring
search. For example, when entering "100" also find "AL100".
Currently, a starts-with search was used.
This is simply done by setting the "filterMode" of the
ComboBoxDelegate to "Qt::MatchContains".
Suggested-by: Miika Turkia <miika.turkia@gmail.com>
Signed-off-by: Berthold Stoeger <bstoeger@mail.tuwien.ac.at>
Dives for the seac action computer are imported by the seacsync
program into two tables in an sqlite3 database.
The dive information is read from the headers_dive table.
The dive_data table is then queried for each dive to get samples.
The seac action computer is the only current supported computer
by the seacsync program. It only supports two gas mixes, so the
parser will toggle between two cylinders whenever it detects a
change in the active O2 mix.
Dive start time is stored in UTC with a timezone offset.
A helper function to read this was added to qthelper.
Default cases have been added to some switch statements
to assist in future development for other dive types and
salinity.
Example database has been added to ./dives/TestDiveSeacSync.db
Signed-off-by: James Wobser <james.wobser@gmail.com>
The way we export the profile image (as direct export but
also used for printing) is that we render the profile
from the screen to a Pixmap and save that to a file. Unfortunately
this results in very bad resultion and a blurred image.
This is an attempt to improve that situation but it's still far
from perfect: Rather than a QPixmap and grab, I now use a QImage
(where I can set the size) and render, and indeed the picture resolution
(when vied at fixed size) get's better this way. The disadvantage
is that icons get smaller at the same rate und so
there is a natural limit on how big we can get. Maybe somebody
with better Qt knowledge can take off from here. In my opinion
this is already a step in the right direction.
Signed-off-by: Robert C. Helling <helling@atdotde.de>
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
When the dive has no explicity salinity, our conversion
between pressure and depth assumed salt water. Make this
explicity by using the corresponding macro.
When the planner starts and no salinity is set explicity,
set the water type chooser to salt water to reflect
our default assumption.
Signed-off-by: Robert C. Helling <helling@atdotde.de>
This new option allows a user to select a new destination tank for an
existing "Gas Change" event. This is useful when Subsurface's heuristics
get tanks wrong after an import from a divecomputer. The use-case arose
from sidemount divers with air-integrated transmitters as well as carrying
a deco tank.
Signed-off-by: Michael Werle <micha@michaelwerle.com>
When setting up a dive for replanning, we ignored zero length segments as those
tend to be generated by gas changes. But it is possible to enter those in the
planner and the replanning should not ignore those. So be
more clever about gas changes. Let's add 10 seconds so we are not at two depths
at the same time and help since add_stop also does not like zero length
segments (it thinks we are trying to replace a waypoint).
Fixes#2901
Signed-off-by: Robert C. Helling <helling@atdotde.de>
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
0249e12 split up the dive import logic in multiple steps. Thereby,
the one of the conditions for renumbering the imported dives (is
the last old dive numbered) got messed up: The first number of the
new dive was compared to the total number of old dives, which makes
no sense.
- Simply check for the number of the last existing dive (if any).
- Don't remember the number of old dives - the original table is
not modified anyway.
Fixes#2731
Signed-off-by: Berthold Stoeger <bstoeger@mail.tuwien.ac.at>
A while ago, we introduced a preference whether O2 should
be considered narcotic. We used this when computing
best mix or when entering the He content via MND. But
we forgot to make the displayed MND depend on this
preference. This patch add this.
Fixes#2895
Signed-off-by: Robert C. Helling <helling@atdotde.de>
We did something really horribly wrong when merging cylinders. It's
been broken since commit 7c9f46a ("Core: remove MAX_CYLINDERS
restriction"), and used some really strange logic.
This rewrites the logic to be (I think) a bit more easy to understand.
Signed-off-by: Linus Torvalds <torvalds@linux-foundation.org>
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
The last time those changed, we forgot to update serial_ftdi. In that change
set_latency had been removed from libdivecomputer and poll and ioctl had been
added. This caused the callbacks to no longer be aligned correctly and the
functions were called with the wrong arguments through the wrong function
pointers, leading to crashes.
Instead of the fragile assumptions about order and type of function pointers,
use named initializers. And while we are at it, fix that for the bluetooth
implementation as well.
Signed-off-by: Linus Torvalds <torvalds@linux-foundation.org>
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
Having a lot of tags (or more precisely, a tags string that is very long) could
cause the width of the dive details view to extend past the width of the the
page. The txtTags label was missing a maximum width, and to make the result
more useful, I also added correct wrapping and elide to the mix (stupidly, we
had the wrap and width for the fixed name of the field ('Tags'), but not for
the user determined content of that field).
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
The UI is ugly, and of course this is hidden in the developer options that have
to first be enabled in the advanced settings. As I mentioned in the previous
commit, I believe the actual risk that something gets damaged here is very low,
but still, explaining this so it makes sense to the casual user may be a bit...
difficult.
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
This is a partial revert of commit 99438121c4 ("mobile/dive-edit: use template
components and theme colors")
Clearly the information given in the Qt documentation on how to theme ComboBox
is flat out broken. The trade-off between 'better dark theme' and 'broken user
experience' is fairly easy to make.
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
I could have sworn that I have fixed this several times in various places,
but apparently (as shown by todays support emails) it's still possible to
setup a mixed case email address. So let's try to solve this problem at
the very top.
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
The salinity value was not displayed with localized thousands separators.
E.g. to a user of a German locale the density read as slightly over
1 g/l, when it should be approximately 1000 g/l. For consistency, also
localize that value.
Also localize the CNS and OTU numbers, even though these should
(hopefully!) never come with thousands separators.
Signed-off-by: Berthold Stoeger <bstoeger@mail.tuwien.ac.at>
This was more painful than expected, because we get the "preferences"
changed signal too early when the user switches to system format.
The correct format is set by the preferences-widget, not the preferences
subsystem.
Signed-off-by: Berthold Stoeger <bstoeger@mail.tuwien.ac.at>
The old code used get_taglist_string() and split the resulting
string at commas to get the list of tags. This was wrong for two
reasons:
1) It was buggy. Every tag but the first would start with a leading
space and thus not be found.
2) It was inefficient. The tag list was concatenated, just to be split
again.
Turn the tag list directly into a QStringList and remove whitespace
for good measure.
Fixes#2842.
Reported-by: Hartley Horwitz <hhrwtz@gmail.com>
Signed-off-by: Berthold Stoeger <bstoeger@mail.tuwien.ac.at>
This was an old "optimization" to avoid double plotting of the
pictures, first by the profile itself, then by the picture tab.
Since the profile now updates the pictures itself, this must
be removed: The picture tab doesn't do it anymore.
Fixes#2833
Signed-off-by: Berthold Stoeger <bstoeger@mail.tuwien.ac.at>
If the user asks to have all BT/BLE devices shown, we should behave
consistently to the case of a recognized dive computer and always show the
device name. In almost all cases the BT/BLE address (and even worse on
iOS/macOS the weird uuids) are completely meaningless.
If there isn't a name, don't add a leading space in order to make it easy to
detect if we have an address without a name (which almost certainly isn't a
dive computer, so it should be towards the end of the list of addresses - which
will be handled in a later commit).
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
This fixes a rather subtle bug.
In btdiscovery.cpp we are detecting dive computers based on their BT name and
are setting up product+vendor as the key for that lookup. QMap always uses case
sensitive comparisons and a tiny inconsistency snuck into our code.
libdivecomputer names for the Aqualung dive computers i200C / i300C / i550C end
in an upper case C (as matches the official branding), but in btdiscovery.cpp
we have those names with lower case c. And therefore didn't recognize these
dive computers.
Obviously this is easy to fix by fixing those three strings, but I decided that
it was silly to set ourselves up for similar oversights in the future. So
instead I switched the matching of the descriptor to simply be allways all
lower case.
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
This includes cleaning up the old CHANGELOG I forgot to delete for the release
as well as mentioning the libdivecompute updates.
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>
The cylinder-based statistics where not updated when an undo
command edited cylinder data. Do so.
Signed-off-by: Berthold Stoeger <bstoeger@mail.tuwien.ac.at>
When plotting profiles with surface segments, there were strange
artifacts. As we found out with Robert, these were due to the fact
that the calculated maxtime was set to the last event which is just one
second inside the surface segment. This terribly confused the profile
code. For example, it didn't properly allocate samples for the surface
segment.
Thus, when calculating maxtime, consider the last sample beyond the
last event.
Signed-off-by: Berthold Stoeger <bstoeger@mail.tuwien.ac.at>
I'm not sure if Google used to show the POI marker at the center location in
the past or if this is actually a new feature. Either way this appears to do
the right thing in my testing.
Note that we need a 'plus' to connect the point of interest cooridnates,
but a 'comma' to connect the map center coordinates.
Reported-by: Chirana Gheorghita Eugeniu Theodor <office@adaptcom.ro>
Signed-off-by: Dirk Hohndel <dirk@hohndel.org>